HomeMy WebLinkAboutEngineered Plan - 200738.01 SLAB -30.5 1 A�RpAD. ACCESS COVERS MUST BE WITHIN 6' OF FINISH GRADE �i 4 GAS BAFFLE EXISTING 1000 GAL SEPTIC TANK INSPECTION PORT FIRST 2' TO BE LEVEL -7 9' MINIMUM. 3' MAXIMUM COVER MI N 2 " OF PEAS TONE 3/4' - 1 I/2' DIA. 75,(t-l�\ 30.5 /0' �a DOUBLE WASHED STONE 67 a 30.43 29.6 III 3 OUTLET 4 HIGH CAPACITY INFILTRATOR D -BOX CHAMBERS W/3.5'f STONE AROUND 10'w x 32'1 x 10'd 6' CRUSHED STONE OR COMPACTED BASE LOCUS MAP Q l0 20 40 O -G OHW- -E- - T- -CTV- +40.4 4n_ INVERT ELEVATIONS: INVERT OUT SEPTIC TANK: 33. 75 INVERT IN DIST, BOX: 30.67 INVERT OUT DIST. BOX: 30.5 INVERT IN LEACH CHAMBER: 30.43 BOTTOM OF LEACH CHAMBER: 29.6 ADJUSTED GROUND WATER: 24.3 OBSERVED GROUND WATER: 20.8 BOTTOM OF TEST HOLE 20.8 INDEX WELL A I W 230. ZONE C AUGUST 07 READING -24.0', ADJ-3.5 ' HYDRANT GAS LINE OVER HEAD WIRES LIGHT POST UNDERGROUND ELECTRIC LINE UNDERGROUND TELEPHONE LINE UNDERGROUND ACABLEVIS/ON LINE . IIA i' SPOT ELEVATION EXISTING CONTOUR PROPOSED CONTOUR DESIGN CRITERIA: GENERAL NOTES: DESIGN FLOW: 2 BEDROOMS AT //0 G.P.D. PER I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION BEDROOM EQUALS 220 G.P.D. OF THE SEWAGE DISPOSAL SYSTEM ONLY. NO GARBAGE GRINDER 2. VERTICAL DATUM /S ASSUMED. FOR BENCH MARKS SET. SEE SITE PLAN. SEPTIC TANK REQUIRED: 220 G.P.D. X 200x - 440 GAL. 3. ALL CONSTRUCTION METHODS AND MATERIALS AND SEPTIC TANK PROVIDED: 1000 GAL. EXISTING MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND' LOCAL SOIL ABSORPTION SYSTEM REOU/RED: BOARD OF HEALTH REGULA TIONS. DESIGN PERC RATE C 5 MIN/INCH SOIL TEXTURAL CLASS- l 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER EFFLUENT LOADING RATE - 0.74 GPD/SF AREAS.SUBJECT TO VEHICULAR TRAFFIC OR GREATER 220 GPD / 0.74 GPD/SF - 297 S.F. REQUIRED THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. PROVIDED: 4 HIGH CAPACITY INFILTRATOR CHAMBERS W/3.5'+ STONE AROUND. A-390 S.F. 5. ALL' SEWER PIPE SHALL BE SCHEDULE 40 OR 390 S.F. x 0.74 -268 GPD APPROVED EQUAL. SO I L TES T P I T DATA ® 6. SEPTIC TANK AND D- BOX SHALL BE REINFORCED PRECAST CONCRETE AND WATERTIGHT. D -BOX SHALL I NO /CA TES 17 INDICATES BE WA TER ' TES TED TO CHECK FOR LEVEL WHEN THERE PERCOLATION _ OBSERVED IS MORE THAN ONE OUTLET. TEST - GROUNDWATER 7. BEFORE COSTRUCTION CALL 'DIG -SAFE'. TP #1 1 -888 -DIG , -SAFE AND THE LOCAL WATER DEPT. HORIZON TEXTURE COLOR FOR LOCA TION OF UNDERGROUND UTILITIES. 0" 33.0 LOAMY IOYR 8. EXISTING LEACH PIT TO BE PUMPED DRY AND SAND 3/3 BACKFILLED. 8 - .......................................... 32.3 LOAM B SANDY 5/8R 9• THE SEWER LINE BETWEEN THE DWELLING AND THE TANK MAY NEED TO BE REPLACED. C / MEDIUM 10YR SAND 5/8 42 146- 1 0 DATE: SEPTEMBER l9. 2007 TEST BY: STEPHEN HAAS WITNESSED BY: AMY VONHONE PERC RATE: l 2 M/N/INCH Ynrmouth Venlib Mparttment L'aPPEZ is I Na mp Date .� )) rmii yam, 4. .r 20.8 7 L f A. +� r .�tj lairs ;j. �4�'r�iL� �. •;� DEC 0 6 200 HEALTH M S E- P T/ C SYS 7_E_"- O E S/ G /V 20 BU01<W00D DR / VE. MAP 88 PARCEL 200 SOUTH YAR OUT/, . "A. PREP!-� RED FOR : B R E /V D A WI -1 / T E f -HEA 0 SCAL E : / - 20 IVO VEMBER 26 . 2007 EAGLE SUFRVEYI NO I NC 923 Route 6A Yarmauthport MA. 02675 ( 508) 362-8132 �1�►/ I ( 508) 432-5333 JOB NO: 07-092L- F l EL D : CFW/EEK CAL C : SAH/CFW CHECK: CFW DRN : SAH A,