Loading...
HomeMy WebLinkAboutEngineered Plans - 2014SCALE: 1"=20' LEGEND PROPOSED CONTOUR 98 PROPOSED SPOT GRADE -- 98 -- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE W— EXISTING WATER SERVICE & TEST PIT Yarmouth Health Departrnent %APP&VED fame Date GENERAL NOTES: i. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V. AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 10. EXISTING LEACHING (IN SAME LOCATION AS PROP. LEACHING) TO BE REMOVED AND REPLACED WITH CLEAN MEDIUM SAND PER TITLE 5. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY 13. NO PRIVATE WELLS WITHIN 150 FT. OF PROPOSED LEACHING 14. ALL PIPE TO BE 4" SCH 40 ® 1/8"/FT (UNLESS SPEC. OTHERWISE) 15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER 16. NO WETLANDS WITHIN 100 FT. OF PROPOSED LEACHING 17. REMOVE UNSUITABLE SOILS 5 FEET AROUND LEACHING TO EL. 5.90 OR TOP OF C LAYER AND REPLACE WITH CLEAN MEDIUM SAND PER TITLE 5. 18. PLACE RAILROAD TIES AT END AND SIDE OF DRIVEWAY TO PREVENT VEHICULAR TRAFFIC OVER LEACHING AND D -BOX WEST YARMOUTH LOCUS 26 CIRCUIT RD. LOCUS MAP LOCUS INFORMATION TITLE REF: 20012/290 PARCEL ID: 49/267 FLOOD ZONE: "C" COMMUNITY PANEL: 250015-0005-D DATED:07/15/92 SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 26 CIRCUIT ROAD WEST YARMOUTH, MA PREPARED FOR NEIGHBORHOOD WASTEWATER SERVICES MARCH 20, 2014 of MAss9� PARRE M. yG� i. MEY�t,, No. Z A0 �i L' ' MEYER & SONS, INC. P.O. BOX 981 EAST SANDWICH, MA. 02537 (508)362-2922 SHEET 1 OF 2 J##1547 NOTE: TO PREVENT BREAKOUT, THE PROPOSED NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS FINISH GRADE SHALL NOT BE < EL:9.29 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. SEPTIC TANK PROPOSED D-BOX PROPOSED S.A.S. T.O.F. EL.=12.10 INSTALL RISERS & COVERS OVER INLET & INSTALL RISER &COVERINSTALL A 4" DIAMETER INSPECTION PORT OVER �F Mqs OUTLET AND SET TO 6" OF FINISH GRADE SET TO 6" OF GRADE ONE CHAMBER (MIN.) AND SET TO 3" OF F.G. . F.G. EL=11.5± F.G. EL.=1 1.65± F.G. EL: 10.0± F.G. EL: 10.04(MAX.) DAME _M� 1140 9" MIN COVER/ L = 10' 36" MAX COVER L = 20' ® S=1% MIN. (MIN.) EL. 10.90 0 S=17 L 10'(MAX) INSTALL TWO INSPECTION PORTS (MIN.) p = (MIN.) 4"SCH40 PVC 4"SCH40 PVC 0 5=1i (MIN.) 4"SCH40 PVC S NtTAR INV.=9.90 s 3.3" TO as" LIQUID INV.=9.65 �' LEVEL GAS BAFFLE PROPOSED INV.=9.20 4 ROWS OF 6 UNITS AT 4.0'/UNIT = 24.0'/ROW D BOX INV.=9.40 INV.= 8.90 SOIL ABSORPTION SYSTEM (PROFILE) PROP 1.500 GALLON SEPTIC TANK 48" RESTORE VEGETATIVE COVER EXISTING OUTLETS BACKFILL WITH CLEAN PERC SAND INV.=10.10 TO TOP OF CHAMBERS BREAKOUT=TOP ELEV.=9.29 34" NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTINGINV. ELEV.= 8.90 PIPE INVERTS PRIOR TO CONSTRUCTION.41 BOTTOM ELEV.= 8.62 EXISTING SUITABLE 2) TANK AND D-BOX SHALL BE SET LEVEL AND 2.83' MATERIAL TRUE TO GRADE ON A MECHANICALLY COMPACTED 5' MIN. ABOVE BOTTOM OF SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN T.P. EXCAVATION OR G.W. EFFECTIVE WIDTH = 4 x 2.83' = 11.32 310 CMR 15.221(2) ( (5.05' PROVIDED) USE 4 ROWS OF 6 INFILTRATOR QUICK 4 PLUS PROFILE 3) INSTALL INLET & OUTLET TEES W/ ADJ. GROUNDWATER EL.=3.57 __ STD LP (3.3" INVERT) UNITS-NO STONE GAS BAFFLE AS REQUIRED 1 48„ SEPTIC SYSTEM PROFILE TYPICAL SECTION ftnTm W. MM V. M.» N.T.S. N.T.S. 3.3 DESIGN CRITERIA SOIL LOG I SECTION END CAP NUMBER OF BEDROOMS: 2 BEDROOM EXIST/3 BEDROOM DESIGN DATE: MARCH 6, 2014 SOIL TEXTURAL CLASS: CLASS I SOIL EVALUATOR: DARREN M. MEYER, R.S., CSE #1614 INFILTRATOR QUICK 4 PLUS STD LP (3.3" INVERTIl UNITS 1 DESIGN PERCOLATION RATE: <2 MIN/IN WITNESS: PHIL RENAUD, YARMOUTH HEALTH DAILY FLOW: 330 G.P.D. DESIGN FLOW: 330 G.P.D. Eley. TP-1 Depth GARBAGE GRINDER: NO (NOT DESIGNED FOR GARBAGE GRINDER) FOR TESTHOLE 41, 9.90 FILL 0" MODEL QUICK4 LP PROPOSED SEPTIC TANK: 330gpd x 200 = fifi0 gpd (USE NEW 1,500G TANK) WELL: MIW-29 ZONE: A 7.57 A 28" LOAMY SANDTO LENGTH 48" NOTE: UNIT CONFIGURATION AND AVAILABILITY SUBJECT LEVEL: 5.3 ADJUSTMENT. 1.7 EFFECTIVE LENGTH 48" CHANGE WITHOUT NOTICE. PRODUCT DETAIL MAY LEACHING AREA REQUIRED: (330) = 445.95 S.F. USE BOH ALLOWED ADJUSTMENT OF 1.0' 6.90 B 36' DIFFER SLIGHTLY FROM ACTUAL PRODUCT APPEARANCE. GROUNDWATER OBSERVED AT $8" EL'2.57 SIDE WALL HEIGHT 3.3" ,74, D ADJUSTED GROUNDWATER AT EL 3.57 LOAMY 10YR SAND OVERALL HEIGHT 8" DISTRIBUTION BOX: (4 OUTLETS (MINIMUM)) 5'90 C1 48" OVERALL WIDTH 34" PRIMARY S.A.S. MEDIUM SAND USE 4 ROWS OF 6 - INFILTRATOR QUICK 4 STD LP (3.3" INVERT) PERC TEST 2.5Y 6/4 o EL 4.40 CAPACITY UNITS WITH NO STONE PROPOSED SEPTIC SYSTEM/SITE PLAN BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF OF CHAMBER) 0.90 t08" (CHAMBER UNITS) 24 UNITS x 4.00 LF x 4.73 SF/LF = 454 SF PERC RATE <2 MIN/IN. (Cl" HORIZON) 26 CIRCUIT ROAD, WEST YARMOUTH, MA Prepared for: Neighborhood Waste Water Services TOTAL AREA = 454 SF Design and Site Plan by: MEYER & SONS, INC. SCALE NTS DRAWN D.M.M. DESIGN FLOW PROVIDED: 0.74GPD/SF(454SF) = 335.9 GPD > 330 GPD req'd ' 1, Darren M. Meyer, R.S., CSE, hereby certify that I am currently approved by MADEP pursuant to 310 CMR 15.017 PO BOX 981 CHECKED to conduct soil evaluations and that the above analysis has been performed by me consistent with the EAST SANDWICH, MA 02537 DATE: SHEET NO. requirements of 310 CMR 15.017. 1 further certify that I have passed the Soil Eval. Exam in October, 1999. 508-362-2922 03/20/14 D.M.M. 2 Of 2