HomeMy WebLinkAboutEngineered Plan - 1997v" A N %Z -kfo* 5§11 ­,Ts Nl: v7t"7� _.lm__ i, :p , , �� , - , 97,7_"'� k GENERAL NOTES:- INVERT EL EVA T I ONS DESIGN CRITERIA: ACCESS COVERS MUST RE V17HIN 9* MINIMLN. INVERT AT BUILDING: 102.15 DESIGN FLOW: 5' OF FINISH GRADE 1. THIS PLAN I$ FOR THE DESIGN AND CONSTRUCTION 04 5 3* MAXIMU14 COVER w INVERT IN SEPTIC TANK: 101,75 _"EDROOMS AT 1/0 G.P.D. PER OF THE MAW DISPOSAL SYSTEM ONLY. FIRST 2 TO RE MIN 2* OF PEA$TONE INVERT OUT SEPTIC TANKz 101.5 BEDROOM EQUALS 441L.-G.P.D. LEVEL --n ALL CONSTRUCTION METHODS AND MATERIALS AM 4* PVC INVERT IN DIST. BOX: 101.04 M4/NTEX4NCF OF TW SEPTIC SYSTEM SHALL 314' - 1 112' DIA. NO GARBAGE GRINDER COWNIM M A%W. D.E. P. TI ME 3 AND LOCAL SCHEDULE 46_� INVERT OUT DIST. BOX: LQQ, 87 WASHED STONE loo, 71rw BOARD OF HEAL lff NE04tATIONS. INVERT IN LEACH CHAMBER: 100.75 10/ 7 8 STANDARD INFILTRATOR$ SEPTIC TANK REQUIRED: _J_ OUTLET W/4' STONE AROUND. I1 50 • BOTTOM OF LEACH CHAMBEk.---100. 25 J. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER 10' MIN. D-BOX 440 G. P.D. X 200% 880 GAL. OF AAEA$ SUBJECT TO VEHICULAR TRAFFIC OR GREATER 1592 6AL ADJUSTED GROUND WATER: 95.75 SEPTIC TANK PROVIDED: 1500 GAL. IrKM J ' IN DEPTH $IA4LL BE CAPABLE OF WI TH- SEPTIC TANK 61 CRUSHED $TONE BASE OBSERVED GROUND WATER: 95.75 STANDING H-20 WHEEL LOADS. BOTTOM OF TEST HOLE: 95.5 SOIL ABSORPTION SYSTEM REQUIRED: 4, ALL SEWS PIPE $HALL BE SCHEDULE 40 OR PROF I L E: NOT TO SCALE INDEX WELL AIW 247. ZONE 8 DESIGN FERC RATE 5 MIN/INCH -APPROVED EQUAL. 5197 READING-20.7. 0.0' ADJ SOIL TEXTURAL CLASS EFFLUENT LOADING RATE 0.7 GPD/SF 5. SEPTIC TANK AND DISTRIBUTION BOX TO BE B•63• - 440 GPD / 0, 7- GPDISF - 595 S.F. PRECAST REINFORCED CONCRETE AND WATERTIGHT. O. BEFORE CONSTRUCTION CALL 'DIG-SAFE'. PROVIDED: 6 STANDABD INFILTRATORS 100. EOW I % We 1-800-322-4844 AND THE LOCAL WATER DEPT.os o +103.7 W14 STONE AROUND. A-61 I F. FOR LOCATION OF UNDERONOUND UTILITIES. -------------- f. VERTICAL DATUM IS: ASSUMED 102. 41 SOIL TEST PIT DATA FOR BENCH MARKS SET. SEE SITE PLAN. INDICATES V INDICATES +1".7 PERCOLATION OBSERVED 9. &XISTING CESSPOOLS TO BE PUMPED DRY AND +102 6 TEST OR OUND NA TER BACKFILLED. v% I I 7P* EON 4 1 ve 600 EL. /03-0 MEDW F'*vo 4 95.75 Ears G. W. EL I , 102. t f 0. HORIZON TEXTURE COLOR OTHER 103.0 +100.3 LOAMY IOYR E" 2 A SAND 312 S' JAP AMPLE 07.3 -VA 9 102.3 LOAMY I OYR SAND 5/8 .............. ...................................... It IL It LILACO 102.0 C MEDIUM /OYR of p 1�4 SAND 816 s I T46 VARIANCES REQUIRED: TITLE 3: MAX IMU14 FEAS19LE COMPLIANCE SECTION 15.212:lbl DEPTH TO GROUND WATER PATIO *011STAME OF S' ABOVE ROW WATER IS I - I I \CESSPOOL +102.3 100.27 95.75 SEQUINED. 4.5* IS PROPOSED. A 0.5' VARIANCE 1 0 07 I \EOW 3 IS REQUESTED. �J. +100. 12 Eor 3 &L SEPTIC VA CESSPOOL FINSN AUVE 4. 1997 DATE: JUNE AV. coo Nf At. 4 14' TEST By• STEPHEN HAAS EL - 103. 0 4 AMY VONHO E WITNESSED By: 2 MIN/INCH PERc RATE: J4"WILLOW _P 7- 0 _M S 0M lef. a-M1o._�---, LOT 22 S YS TE DE 101.3 37624 1 S F. +Iw. I "A P -94 RA R (::-E-L N2 2 rar WE YAR"OUTIIROR r, "A S ---------- 8 SWUND IAWFIL roftes P R iFRA R ECJ F:_ 0 R J U L 7 1997 W/ 4' MWE Y los.o\\ ��`` _ __ ..� HEALTH DEPT. 0 \5 E_ p c- y `;�� �` \` k _Q S TA R UCK LAVE. IV�F. YARA40U7-"R0R T. "A 024575 0 S S (:.-A L 4F UNE 24. A. ry �f',., No. YVC7 c I, Z .51 vz"Y"z m 0 LO A' 0 4& 4& -7 04 5PVC $C HE CIL 102. 5 la/ ECk: W _97,272 FIELD:rA91PDR' 1,.tALC. $AH1CF# DftN-. SAH' CUS _MAP wo,- CF Zgg ws A A,