Loading...
HomeMy WebLinkAboutEngineered Plans - Rev. 2014TBM = EL. 39.7 BULKHEAD FOUNDATION SCALE: 1"=20' 3G� \ 37 \ Insp. Ports 38 �l i. \ O ry 38� 30.0 r�F F� 46.O CtDqR 5 FT. STRIPOUT (see note 17) // \00` \ \ EX15T. LEACHING (see note 10) 1 01 deck ` \ L-Alvt 3G 37 LEGEND PROPOSED CONTOUR F9-8-1 PROPOSED SPOT GRADE --98 -- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE 1 W— EXISTING WATER SERVICE TEST PIT Permit valid for REPAIR OF Sl':P7lC' SVS,I'E.M ONLY, due to State anal I.Oval septic variances. Board ofliealth review and appro%al is required for any future additions/renu� ation,/c{iterations to sewage facilities. and/or structuresy(I"ellinK. Yarmouth IMaith M-partment APPROVED 6 PROP. 1 , 50OG SEPTIC TANK i)ate 1 i , --35 38.5 GENERAL NOTES: CC) 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL CO BOARD OF HEALTH AND THE DESIGN ENGINEER. (D' 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS cry OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. ! 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING ! ! FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. ! 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. !! 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF ! THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. / 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 1 ! L� 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED `\-7 TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ! THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING / CONSTRUCTION. % 10. EXISTING LEACH PIT TO BE PUMPED, CRUSHED AND REMOVED PER TITLE 5. / ! 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION ! 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY j AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY ! 13. NO PRIVATE WELLS WITHIN 150 FT. OF PROPOSED LEACHING 14. ALL PIPE TO BE 4" SCH 40 0 1/8"/FT (UNLESS SPEC. OTHERWISE) 15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER 16. NO WETLANDS WITHIN 100 FT. OF PROPOSED LEACHING 17. REMOVE ALL UNSUITABLE SOILS 5 FT AROUND LEACHING TO EL. 32.75 OR TOP OF "C" LAYER AND REPLACE WITH CLEAN MED. SAND PER TITLE 5. SOUTH YARMOUTH w z Q J ui w M z a U RD. LOCUS MAP LOCUS INFORMATION LOCUS: 14 OLD CEDAR LN. TITLE REF: BK 27147 PG 309 PARCEL ID: MAP 109 PAR. 056 PROPERTY IS WITHIN A ZONE II FLOOD ZONE: "C" COMMUNITY PANEL: 250015-0002—D DATED:07/02/92 SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 14 OLD CEDAR LANE SOUTH YARMOUTH, MA PREPARED FOR FEDERAL NATIONAL M TG. ASSOCIATION APRIL 22, 2014 REV:04/29/14 - 4 BR DESIGN OF OF (r!" 0PEN SN MEYER o. 1140 ��s.�¢ti SAN I TAR�P� MEYER & SONS, INC. P.O. BOX 981 EAST SANDWICH, MA. 02537 (508)362-2922 SHEET 1 OF 2 628 NOTE: TO PREVENT BREAKOUT, THE PROPOSED NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS FINISH GRADE SHALL NOT BE < EL:36.25 FOR A DISTANCE OF 15' AROUND THE SEPTIC TANK PROPOSED -D -60X PROPOSED S.A.S. PERIMETER OF THE S.A.S. T.O.F. EL.=40.0 INSTALL RISERS & COVERS OVER INLET & INSTALL RISER & COVER INSTALL A 4" DIAMETER INSPECTION PORT OVER OUTLET AND SET TO 6" OF FINISH GRADE SET TO 6" OF GRADE ONE CHAMBER (MIN.) AND SET TO 3" OF F.G. ���` �F MgSf9� F.G. EL.=39.0± F.G. EL.=38.4± F.G. EL: 38.0± F.G. EL: 38.0(MAX.) D d� I 9" MIN COVER] R O. 11 0 L = 19'1 36" MAX COVER L = 12' L = 10'(MAX) INSTALL TWO INSPECTION PORTS (MIN.) 0S=1% (MIN.) EL. = 37.60 ®S=1% (MIN.) ® S=1% (MIN.) 4"SCH40 PVC 4"SCH40 PVC 4"S H40 PVC $jE •� 10" SANITARO' 6" 3.8" TO INV. --36.54 48" LIQUID 14 INVERT tEWl INV.=36.29 PROPOSED GAS BAFFLE D BOX INV.=36.00 4 ROWS OF 7 UNITS AT 5.0'/UNIT = 35.0'/ROW M AM INV.=36.17 DB -5 INV.= 35.90 SOIL ABSORPTION SYSTEM (PROFILE PROPOSED 1.500 GALLON SEPTIC TANK 60" EXISTING SEWER OUTLET RESTORE VEGETATIVE COVER INV.=37.33 BACKFILL WITH CLEAN PERC SAND TO TOP OF CHAMBERS BREAKOUT=TOP ELEV.=36.25 INV. ELEV.= 35.90 34" BOTTOM ELEV.= 35.58 EXISTING SUITABLE 5' MIN. ABOVE BOTTOM OF 2.83' I MATERIAL T.P. EXCAVATION OR G.W. EFFECTIVE WIDTH = 4 x 2.83' = 11.32 (5.05' PROVIDED) USE 4 ROWS OF 7 ARC 36LP PROFILE ADJ. GROUNDWATER EL.=30.53 _ (3.8" INVERT) UNITS -NO STONE SEPTIC SYSTEM PROFILE60" TYPICAL SECTION N.T.S.KQ vs rs 3 8" U DESIGN CRITERIA SOIL LOGf c_T sTlN N CAP -�--� NUMBER OF BEDROOMS: 4 BEDROOM DESIGN PATE: MARCH 27, 2014 SOIL TEXTURAL CLASS: CLASS I SOIL EVALUATOR: DARREN M. MEYER, R.S., CSE #1614 DESIGN PERCOLATION RATE: <2 MIN/IN WITNESS: AMY VONHONE, YARMOUTH HEALTH ARC36 LP (3.8" INVERT UNITS DAILY FLOW: 440 G.P.D. Elev. TP -1 Depth DESIGN FLOW: 440 G.P.D. 37.25 0" GARBAGE GRINDER: NO (NOT DESIGNED FOR GARBAGE GRINDER) 36.25 10'R � 12" MODEL ARC 36LP PROPOSED SEPTIC TANK: 440gpd x 200% = 880 gpd (USE NEW 1,500G TANK) FOR TEMOLE /1• B LOAMYiSS'"A33" ND LENGTH LEACHING AREA REQUIRED: (440) = 594.59 S.F. GROUNDWATER OBSERVED AT 34 60" NOTE: UNIT CONFIGURATION AND AVAILABILITY SUBJECT 101" EL. 28.83 74 INOEx WELL: AIW-247 ZONE: 8 C SANDY WAA� EFFECTIVE LENGTH 60 SIDE WALL HEIGHT 3.8" TO CHANGE WITHOUT NOTICE. PRODUCT DETAIL MAY LEVEL: 23.4 ADJUSTMENT: 2.7 ft. 10YR 6/4 DIFFER SLIGHTLY FROM ACTUAL PRODUCT APPEARANCE. **ADJUSTED GROUNDWATER ELEVATION 30.53** 32'75 C1 54" DISTRIBUTION BOX: (4 OUTLETS (MINIMUM)) VARIANCE -USE HEIGHT WCE-USE BOH ALLOWED 1' REDUCTION g°' OFF ADJUSTMENT (USE 17') FISAND . WIDTH PRIMARY S.A.S. 2.5Y 7/3 OVERALL 34" USE 4 ROWS OF 7 - ARC36LP LOW PROFILE 8" INVERT SIEVE O 31.75 CAPACITY UNITS WITH NO STONE 26.75 126" BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF OF CHAMBER) PERC RATE <2 MIN/IN. ("Cl" HORIZON) PER SIEVE TEST PROPOSED SEPTIC SYSTEM/SITE PLAN (CHAMBER UNITS) 28 UNITS x 5.00 LF x 4.73 SF/LF = 662.2 SF 14 OLD CEDAR LANE, SO. YARMOUTH,MA TOTAL AREA = 662.2 SF Prepared for: FNMA/DEDECKO DESIGN FLOW PROVIDED: 0.74GPD/SF(662.2SF) = 490.0 GPD > 440 GPD req'd Design and Site Plan b 9 Y SCALE DRAWN DATE: * 1, Darren M. Meyer, R.S.. CSE, hereby certify that I am currently approved by MADEP pursuant to 310 CMR 15.017 MEYER& SONS, INC. NTS D.M.M. 04/22/14 to conduct soil evaluations and that the above analysis has been performed by me consistent with the PO BOX 981 requirements of 310 CMR 15.017. I further certify that I have EASTSANDWICH, U4 02537 REV. DATE: CHECKED SHEET NO. fY passed the Soil Eval. Exam in October, 1999. 50"2-2922 04/29/14 D.M.M. 2 of 2