Loading...
HomeMy WebLinkAboutEngineered Plans - 2014LEGEND N c r �o o EXISTING SPOT GRADE �aoAh X 100.98 �' �° o { DECK / - 102 - EXISTING CONTOUR �Cy r o --- OVERHEAD WIRES ° BED r. QG 9� CBdh29 ��o U UNDERGROUND WIRES o�66 a ROOM tBATJKITCH. DIN � W EXISTING WATER SERVICE ROOM �9 1 x 99,47 EXISTING GAS SERVICE White Rock Rd c cL. CL. c . HALL P GARAGE TEST PIT T. LOCUS BED BED LIVING Q} BENCHMARK o ROOM CL DOMROOM CL CL. „ �0 VENT 5 N INSPECTION PORT CONVENTIONAL S.A.S. FOOTPRINT Q Perch J ; �r�a Pond moo ao E115ha5 Pond _ FRONT-'� 1 8N 107 7�� 1p� 101,20 (See Sheet 2) EXISTING LEACH PIT 3v FLOOR PLAN LOCUS MAP 110 � SHED TO BE PUMPED, FILLED WITH SAND AND ABANDONED NOT TO SCALE X P �� 1� + 111,56 07,35 ..,_ GENERAL NOTES: 109,40 L i TP ~ \ BENCHMARK SET / + 105.33 TOP OF SONOTUBE 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL EXISTING SEPTIC TANK ��J + 0 .52o EL.=f08.12(ASSUMED) BOARD OF HEALTH AND THE DESIGN ENGINEER. TOP OF TANK, EL.107.71 112.24 ci0 - ry 2• ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS INV.(OU T)=106.38±x " OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE x 111.27 10 6 108,55 107.71 LOCAL RULES AND REGULATIONS EXCEPT AS REQUESTED BELOW: 310 CMR 15.405(1)(b): Rei•x 107.83 1) A 2' variance to the 3' maximum cover requirement, for up yv PATIO DECK �'D� to 5' of cover. S.A.S. shall be vented and H-20 Rated. 11L68 S�oVe 107,67 108.58 x cr, 1 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR 1 — 107,47 TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. w 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING ! %EXISTING� p FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN lid for REPAIR OF SF:P"TIC sysl'r:M 'HOUSE "' ENGINEER BEFORE CONSTRUCTION CONTINUES. [tie to State and Local Septic varianrc•. 1 '} ti� GARAGE T.O.F.= 108. 0.± 107,46 0 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. iealth review and approval a required fok to Po tire additions/reomation,ialterations t1lr � '— 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF 00 THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF F ilities and/or structw es/dwelling. Vn HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. armouth Health i)epar•tment / 107,95 107.57 �P��� OF MASX4 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. AI'YROVH�ll J 1X C6 o PETER T. GJ �� 8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S. �7 LOT 24 ��B PAVED x 10249 McENTEE 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS 105-21 o CIVIL AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE MBLU 106 No. 35109 DIRECTED BY THE APPROVING AUTHORITIES. �==--- -_,11 12,000 S.F.f a��104,07 �'fGIS�E��� `Q 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY Date 110, 0 X 0 0DRIVEWAY x 110.06 FS 0 THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. Gx 107.91 lOt3 104 103, `a � 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS 100100,00' �' 7 1, IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND 106,22 p2 x 10110 REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). CBdh 1 1. 0'54'30" E N 3 CBdh 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND 104,51IL 1d4 99,83 IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY. E 102 �< PROPOSED SEPTIC SYSTEM UPGRADE PLAN 102,49 edge of pavement 100,57 99,49 97,68 42 RIDGEWOOD DRIVE, YARMOUTHPORT, MA RIDGEWOODDRIVE Prepared for: Capewide Enterprises, 153 Commercial St, Mashpee, MA 02649 OWNR OF RECORD Engineering by: SCALE DRAWN JOB. NO. MCMULLEN, BEATRICE E Engineering Works, Inc. 1 "=20' P.T.M. 129-14 • 100,00 PK SET 42 RIDGEWOOD DRIVE 12 West Crossfield Road, Forestdale, MA 02644 DATE CHECKED SHEET NO. HOUSE LOCATION TAKEN FROM CERTIFIED PLOT PLAN BY JOSEPH M. MONAHAN, JR., YARMOUTHPORT, MA 02675 (508) 477-5313 4/7/14 P.T.M. 2 Of 2 REGISTERED LAND SURVEYOR, SOUTH DENNIS, MA, DATED 6/30/78 NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL:103.33 // FOR A DISTANCE OF 15' AROUND THE GARAGE PERIMETER OF THE S.A.S. BACK OF HOUSE S SEPTIC TANK PROPOSED D -BOX PROPOSED S.A.S. INSTALL RISERS & COVERS OVER INLET & INSTALL RISER & WATERTIGHT INSTALL INSPECTION PORT OVER END UNIT VENT T.O.F. OUTLET AND SET TO 6" OF FINISH GRADE COVER SET TO 6" OF GRADE CHARCOAL DECK EXISTING F.G. EL.=107.71 F.G. EL.=108.0± F.G. EL.=106.0 to 108.3(MAX.) RECOMMENDED CONNECT MAINTAIN 2% GRADE MIN. OVER S.A.S. ALL ROWS s1,). 7=7 L 9' L 14'(MAX) INSPECTION PORT ® S=1% (MIN.) ® S=1% (MIN.) 4"SCH40 PVC 4"SCH40 PVC -� 0. TOP LOAD UNITS 1o"I 14" 6 19" TO I �QOS�O ♦ 0� EXISTING 48" LIQLEVEUID INV.=105 60 INVERT y �� ♦ PRS P � ADD INV.=105.77 PROPOSED i p GAS BAFFLE INV.=103.58 4 ROWS OF 4 UNITS AT 6.25'/UNIT = 25.0' ��y ♦ ��J INV.=106.38± D-BOX00 (VERIFY) SOIL ABSORPTION SYSTEM (PROFILEi EXISTING SEPTIC TANK H-20 ESTABLISH VEGETATIVE COVER BACKFILL WITHNLtEAN NATIVE OR NOTES: PERC SAND TO TOP OF CHAMBERS S.A.S. LAYOUT 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INV. ELEV.=103.58 „ INVERTS, PRIOR TO INSTALLATION. BREAKOUT=TOP TOP ELEV.=103.33 ;., ?,: '' 2) D -BOX SHALL BE SET LEVEL AND TRUE TO 75" ►� GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN BOTTOM ELEV.=102.00 II III�IIIII�II 310 CMR 15.221(2). 3) INSTALL INLET & OUTLET TEES AS REQUIRED. 5' MIN. ABOVE BOTTOM OF 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE T.P. EXCAVATION OR G.W. EFFECTIVE WIDTH=11.3' AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. EXISTING SUITABLE BOTTOM OF TP, EL=97.0 __ MATERIAL 76 USE 4 ROWS OF 4 -HIGH CAPACITY ADS BIODUFUSER UNITS PROFILE WITH NO SEPARATION BETWEEN EACH ROW & NO STONE SEPTIC SYSTEM PROFILE TYPICAL SECTION N.T.S. 16 CONVENTIONAL S.A.S. FOOTPRINT SOIL LOG 34"� DESIGN CRITERIA FOR ILLUSTRATION ONLY -DO NOT INSTALL cTION END CAP 2-500 GALLON CHAMBERS W/4' STONE DATE: APRIL 3, 2014 13.2' x 25.0 S.A.S. FOOTPRINT SOIL EVALUATOR: PETER McENTEE PE 16" HIGH CAPACITY (H-20) 610DIFFUSER UNIT NUMBER OF BEDROOMS: 3 BEDROOMS BOTTOM SIDEWALL TOTAL WITNESS: AMY VON HONE R.S. HEALTH AGENT SOIL TEXTURAL CLASS: CLASS I AREA AREA AREA TP MODEL 16" HICAP UNITS MUST BE STAMPED H-20 DESIGN PERCOLATION RATE: 3 MIN/IN 330 SF 152 SF 482 SF ELEV. DEPTH 0„ LENGTH 76" NOTE: UNIT CONFIGURATION AND AVAILABILITY SUBJECT TOTAL CAPACITY = 0.74 GPD/SF(482 SF) = 357 GPD 108.5 A EFFECTIVE LENGTH 75" TO CHANGE WITHOUT NOTICE, PRODUCT DETAIL MAY DAILY FLOW: 330 GPD LOAMY SAND DIFFER SLIGHTLY FROM ACTUAL PRODUCT APPEARANCE. DESIGN FLOW: 330 GPD 108.0 IOYR 4/2 6„ SIDE WALL HEIGHT 11.2" GARBAGE GRINDER: NO B OVERALL HEIGHT 16" EXISTING SEPTIC TANK: 1000 GALLON CAPACITY LOAMY SAND toYR 5/8 OVERALL WIDTH 34" 4640 TRUEMAN BLVD HILLIARD, OHIO 43026 LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF 106.0 C 30" PERC 13.6 CF CAPACITY (101.7 GAL) ADVANCED DRAINAGE SYSTEMS, INC. 34"/46•, .74 GPD/SF DISTRIBUTION BOX: 4 OUTLETS (MINIMUM) PROPOSED SEPTIC SYSTEM UPGRADE PLAN MED. SAND 42 RIDGEWOOD DRIVE, YARMOUTHPORT, MA USE 4 ROWS OF 4 HIGH CAPACITY ADS BIODIFUSER 2.5Y 6/6 H-20 UNITS IN STONELESS BED CONFIGURATION Prepared for: Capewide Enterprises, 153 Commercial St, Mashpee, MA 02649 SIDEWALL AREA: NOT APPLICABLE 97.0 138" Engineering by: SCALE DRAWN J08. N0. BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF) PERC RATE <2 MIN/IN. ("C" HORIZON) Engineering Works, Inc. g g NTS P.T.M. 129-14 (BIODIFFUSERS) 16 UNITS x 6.25 LF x 4.73 SF/LF = 473.0 SF NO GROUNDWATER ENCOUNTERED 12 West Crossfield Road, Forestdale, MA 02644 SHEET N0. DATE CHECKED DESIGN FLOW PROVIDED: 0.74 GPD/SF(473.0 SF) = 350.0 GPD (508) 477-5313 4/7/14 P.T.M. 2 Of 2