Loading...
HomeMy WebLinkAboutEngineered Plans - 2005EM TING CESSPOOL TD BE PUMPED & FILLED WITH SAND w Ma p 109 Parcel 15 37352± E,F, 0.86± AC, k N 6 9 °58'35" E �- 150, 00' 3 .. 00 > PROPSEPTE, TANK C 6 $ ,� OUTLET -3 OUTLET -2 .r INV=101.01 INV=10L0t EXISTING 3 BEDROOM ra HOUSE (#EB) '" (Assumed)3,4 STRIM - SEE NOTE 11 I 9- -� ?r 94 Beck r I �tt ZF� ff Ir�6 6 r re I r ` 150, 00' �'�, ,. �!, S 6 9 °58'35" W Edgc, oP po ven;er;t fc,2,9 26' 15-4 12,5 r 41 7 01 s� .,� 'w •sorra `_--__-_- REST CREAT #r S'TE'RN RO,4,0 DRY WELL IS RECDMMENDED FDR LOW PDINT— PLACED A MINIMUM DF 25' FRDM S,A,E Benchmark set Conc, sonotube E1,=96,45 (Assumed) xg PETER T, 9F McENTEE o CIVIL No, 35109 0FANN TERRY $ WARNER No. 38721 he -69 GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS, 3, THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. THERE ARE NO PRIVATE WELLS LOCATED WITHIN 100' OF THE S.A.S. 9. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR, 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND FOR 5 FT. ON ALL SIDES OF THE S.A.S. AND REPLACE WITH CLEAN FILL AS SPECIFIED IN 310 CMR 255(3). 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY. PROPOSED SEPTIC SYSTEM UPGRADE LEGEND WESTERN RD, SOUTH YARMOUTH, MA Prepared for: Larry Oneil, 28 W. Great Western Rd., So. Yarmouth, MA Engineering by: Engineering Mork 12 West Crossfield Rd Forestdole, MA 02644 (508) 477-5313 Surveying by: Terry l XamerF- S. 22 Long Road Harwich, MA 02645 (508) 432-8309 SCALE 1 "=30 gy PROPOSED CONTOUR JOB. NO. 119-05 DATE 4/6/05 F9-91 PROPOSED SPOT GRADE boa 31y _._ 96 EXISTING CONTOUR LOCUS -Y 96,57 EXISTING SPOT GRADE 4- N t Feat W�' Cfo O Rd a� �Y TEST PIT ,nsorne ROUTE 6 ~-~- W " " EXISTING WATER SERVICE Whites Path EXISTING TREE QV LACUS MAP N.T.S. DRY WELL IS RECDMMENDED FDR LOW PDINT— PLACED A MINIMUM DF 25' FRDM S,A,E Benchmark set Conc, sonotube E1,=96,45 (Assumed) xg PETER T, 9F McENTEE o CIVIL No, 35109 0FANN TERRY $ WARNER No. 38721 he -69 GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS, 3, THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. THERE ARE NO PRIVATE WELLS LOCATED WITHIN 100' OF THE S.A.S. 9. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR, 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND FOR 5 FT. ON ALL SIDES OF THE S.A.S. AND REPLACE WITH CLEAN FILL AS SPECIFIED IN 310 CMR 255(3). 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY. PROPOSED SEPTIC SYSTEM UPGRADE 28 W. GREAT WESTERN RD, SOUTH YARMOUTH, MA Prepared for: Larry Oneil, 28 W. Great Western Rd., So. Yarmouth, MA Engineering by: Engineering Mork 12 West Crossfield Rd Forestdole, MA 02644 (508) 477-5313 Surveying by: Terry l XamerF- S. 22 Long Road Harwich, MA 02645 (508) 432-8309 SCALE 1 "=30 DRAWN P.T.M. JOB. NO. 119-05 DATE 4/6/05 CHECKED P.T.M. SHEET N0. 1 Of EXISTING F.G. EL: 100.1 INSTALL RISERS OVER INLET & OUTLET L=36'(MAX.) TO WITHIN 6" OF FINISH GRADE 4" SCH 40 PVC L =97' �•� 4" SCH 40 PVC La S= 2% (MIN.) Io PROPOSED 14 @ S= 1/ (MIN.) 1500 GALLON INV. ELEV.=94.42 SEPTIC TANK INV.EL: 98.25- I7 tNV.EL: 98.00 TALL INLET &OUTLET TEES GAS BAFFLE TO BE INSTALLED ON TIE IN TO THE THREE OUTLET TEE AS MANUFACTURED BY EXISTING SEWER OUTLETS TUF-TITE, ZABEL, OR EQUAL OUTSIDE THE HOUSE. 7 1/2• T 45 1/2' 30 ill' FILL SIDE KNOCK -OUTS WITH MORTAR Tap View 3-4' DIA. INLET 5-4' DIA. OUTLETS 2' ._ ,_ Is• 8 6' Sectlon DISTRIBUTION BOX N.T.S, ®®® 0 E0®® rNE21 INVERT E3®®®®� 24' ER ®®®®0 Ea KNOCKO 2NCOVER4" KNOC LIT 4" KNOCKO SEPTIC TANK & D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2). SEPTIC SYSTEM PROFILE. 3" 62" 500 GALLON CAPACITY, H-10 LOADING CHAMBERS RT.4. 5'-8' N.T,S. Top View 4" Dia. Inlets 4" 4" Dia. Inlets \ i I 5' a Section 1500 GALLON CAPACITY, H-10 LOADING SEPTIC TANK NT.S. -4" F.G. EL: 96.5± SLOPE• Or INSTALL RISER OD -BOX TO GRADEI WITHIN 6' OF FINISH NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL:94.58 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. . • ■ ► M 1 ■ •• PERE. PVC DISTRIBUTION LINES 4" SCH • PVC 147- D T Zl� •i i•••i ii•G•i•'•irti ii•i•ii" •`" ilii i•-•il ''•vi�i� ilii%� �+ �iiii�'ii% �•iii���%%~~�� INV. ELEV. =94.18 BREAKOUT ELEV.=94.58 BOTTOM ELEV.=93.50 4' MIN. ABOVE BOTTOM OF T.P. EXCAVATI❑N OR G.W. HIGH G.W. ELI 89,5 - 40I[meT DATE: AaF i c-'� SOIL EVALUATOR: PETER -8" 4'-7' 48" Liquid Level 4' Elev. TP— 1 4" 3" 95,50 a Section 1500 GALLON CAPACITY, H-10 LOADING SEPTIC TANK NT.S. -4" F.G. EL: 96.5± SLOPE• Or INSTALL RISER OD -BOX TO GRADEI WITHIN 6' OF FINISH NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL:94.58 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. . • ■ ► M 1 ■ •• PERE. PVC DISTRIBUTION LINES 4" SCH • PVC 147- D T Zl� •i i•••i ii•G•i•'•irti ii•i•ii" •`" ilii i•-•il ''•vi�i� ilii%� �+ �iiii�'ii% �•iii���%%~~�� INV. ELEV. =94.18 BREAKOUT ELEV.=94.58 BOTTOM ELEV.=93.50 4' MIN. ABOVE BOTTOM OF T.P. EXCAVATI❑N OR G.W. HIGH G.W. ELI 89,5 - 40I[meT DATE: AaF i c-'� SOIL EVALUATOR: PETER I', McENTEE P.E. INSPECTOR: AMY VON HONE R.S. Elev. TP— 1 depth 95,50 95.0 93.7 89.5 A LOAMY SAND 10YR 3/3 B LOAMY SAND 10YR 5/8 C1 FINE LOAMY SAND AND SILT LOAM 5Y 6/4 (UNSUITABLE) C2 MED. LOAMY SAND 2.5Y 6/3 (NO G W INFILTRATION 83.5 N "c2A HORIzoN) 144" PERC RATE 5 MIN/IN. ("C2" HORIZON) NO CORRECTION FOR PERCHED WATER TABLE ESTIMATED HIGH G.W. EL.=89.5 m 22" SLOPE OF PERF, PIPE = 0.5% 36,0' EFFECTIVE LENGTH SOIL ABSORPTION SYSTEM (PROFILE) Kr.s. 12.5' EFFECTIVE WIDTH SOIL ABSORPTIONSYSTEM (SECTION) N.T,s DESIGN CRITERIA NUMBER OF BEDROOMS: 3 BEDROOMS SOIL TYPE: CLASS I DESIGN PERCOLATION RATE: 5 MIN./IN. DAILY FLOW: 330 G.P.D. DESIGN FLOW: 330 G.P.D. GARBAGE GRINDER: NO PROPOSED SEPTIC TANK: 1500 GAL/500 GAL LEACHING AREA REQUIRED: (330) = 445.9 S.F. .74 ENDS TO BE CAPPED INV. EL.=94.00(END) 2' LAYER OF 1/8'-1/2' DOUBLE WASHED STONE 3/4'-1 1/2' DOUBLE WASHED ST.❑NE o PETER T, McENTEE o CIVIL No, 35109 00)" 12.5' X 36' LEACHING FIELD W/3 -DISTRIBUTION LINES SIDEWALL AREA: (NOT APPLICABLE) 7� " PERCHED GW BOTTOM AREA = TOTAL AREA: 12.5' x 36.0' = 450.0 S.F. DESIGN FLOW PROVIDED: 0.74(450.0) = 333.0 G.P.D.