Loading...
HomeMy WebLinkAboutEngineered Plans - 2014I� 4 OPO �h110 \` < cow \ G G C) UJI Zi C I ' � ,' 24—` �; o 17 uJI -kr= i J � TREE W O 1\ \� i C� , U, 927 � �� � TAGB�L� --_— ELEV=12.00 --�NGVD) 7 - CBA C Z LOT 33 AREA=16,364± S.F. TREE W/ LAM P '7 9.36 1 0 ,DMH LOT 32 so\ SLA LEGEND PROPOSED CONTOUR ® PROPOSED SPOT GRADE — — 98 — — EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE W— EXISTING WATER SERVICE TEST PIT Permit valid for REPAIR OF SEPTIC SYSTEM ONLY, clue to State and Local septic variances. Board of health review and approval is required for any future additions/renoti ations/alterations to sewage facilities and/or structures/dwelling. Yarmouth Health Department APPROVED/A& Same Date LOT 31 SCALE 1 "=20' GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE. TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON NGVD DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 10. EXISTING LEACHING (IN REAR) TO BE CRUSHED, PUMPED AND FILLED. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY 13. NO PRIVATE WELLS WITHIN 150 FT. OF PROPOSED LEACHING 14. ALL PIPE TO BE 4" SCH 40 ® 1/8"/FT (UNLESS SPEC. OTHERWISE) 15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER 16. NO WETLANDS WITHIN 100 FT. OF PROPOSED LEACHING 17. REMOVE UNSUITABLE SOILS 5 FEET AROUND LEACHING TO EL. 8.27 OR TOP OF C LAYER AND REPLACE WITH CLEAN MEDIUM SAND PER TITLE 5. SOUTH YARMOUTH ROgo STERN LOCUS 4 LEEWARD RUN LOCUS MAP LOCUS INFORMATION PLAN REF: LCP 17002B SHA TITLE REF: 587212 PARCEL ID: MAP 91 PAR. 140 ZONING: "R-40" FLOOD ZONE: C" COMMUNITY PANEL: 250015-0004—C DATED:06/17/86 SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 4 LEEWARD RUN SOUTH YARMOUTH, MA. PREPARED FOR MARIAN V. MYERS MAY 2, 2014 1000 OF o� EDWAR ti� �`` DARE4 yb 0A. A �` �P� EYER 1V0' No. 1140 �`d, ' lv AHI A 1* MEYER & SONS, INC. P.O. BOX 981 EAST SANDWICH, MA. 02537 (508)362-2922 SHEET 1 OF 2 J#1642 NOTE: TO PREVENT BREAKOUT, THE PROPOSED NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS FINISH GRADE SHALL NOT BE < EL:9.29 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. SEPTIC TANK PROPOSED D -BOX PROPOSED S.A.S. T.O.F. EL.=13.92 INSTALL RISERS & COVERS OVER INLET & INSTALL RISER & COVER INSTALL A 4" DIAMETER INSPECTION PORT OVER ��, OF At OUTLET AND SET TO 6" OF FINISH GRADE SET TO 6" OF GRADE ONE CHAMBER (MIN.) AND SET TO 3" OF F.G. /-F.G. EL.=1tF.G. EL=12.50E / F.G. EL: 11.501 F.G. EL: 11.50(MAX.) oZ D,AR�REN�t+j�, 9" MIN COVER/ NO. 1140 L = 10' 36" MAX COVER L = 10' ® S=1% {MIN.} EL. = 11.75 ®S=1% (MIN.) L = 10'(MAX) INSTALL TWO INSPECTION PORTS (MIN.) 0 S=1% {MIN.} D 61$TE 4"SCH40 PVC 4"SCH40 PVC 4"SCH40 PVC 'AOITAO' 10" " 14" 6" O - } INV.=10.70 as" Lt4uiD , INV.=10.45 NVERTTr4' ------- L LEVEL I GAS BAFFLE 1 PROPOSED INV.=9.50 D-60 4 ROWS OF 8 UNITS AT 4.0'/UNIT = 24.0'/ROW INV.=9.70 DB -5 INV.= $.90 SOIL ABSORPTION SYSTEM (PROFILE) PROP 1.500 GALLON SEPTIC TANK 48" RESTORE VEGETATIVE COVER PROPOSED OUTLET BACKFILL WITH CLEAN PERC SAND . o INV. 10-92 TO TOP OF CHAMBERS BREAKOUT=TOP ELEV.=9.39 34" NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING INV. ELEV.= 9.00 PIPE INVERTS PRIOR TO CONSTRUCTION BOTTOM ELEV.= 8.72 2) TANK AND D -BOX SHALL BE SET LEVEL AND EXISTING SUITABLE TRUE TO GRADE ON A MECHANICALLY COMPACTED 2.83' MATERIAL 5' MIN, ABOVE BOTTOM OF - SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN T.P. EXCAVATION OR G.W. EFFECTIVE WIDTH = 4 x 2.83' = 11.32 310 CMR 15.221(2) (5.29' PROVIDED) USE 4 ROWS OF 8 INFILTRATOR QUICK 4 PLUS PROFILE 3) INSTALL INLET & OUTLET TEES W/ ADJ. GROUNDWATER EL.=3.43 STD LP (3.3" INVERT) UNITS -NO STONE GAS BAFFLE AS REQUIRED 48» 4) PLUMBING TO BE MODIFIED TO MEET OUTLET LOCATION SEPTIC SYSTEM PROFILE I AND ELEVATION. (PLUMBING PERMIT R£Q'D) TYPICAL SECTION + 8„ N.T.S. H.T.s. J. DESIGN CRITERIA SOIL_ LOG SECTION END CAP NUMBER OF BEDROOMS: 4 BEDROOM DESIGN DATE: APRIL 10, 2014 SOIL TEXTURAL CLASS: CLASS I SOIL EVALUATOR: DARREN M. MEYER, R.S., CSE #1614 DESIGN PERCOLATION RATE: <2 MIN/IN WITNESS: AMY VONHONE, YARMOUTH HEALTH INFILTRATOR QUICK 4 PLUS STD LP (3.3" INVERT) UNITS DAILY FLOW: 440 G.P.D. DESIGN FLOW: 440 G.P.D. Elev. TP -1 Depth _ GARBAGE GRINDER: NO (NOT DESIGNED FOR GARBAGE GRINDER) 11.10 0" FOR TE5THOLE it: p, MODEL QUICK4 LP PROPOSED SEPTIC TANK: 440gpd x 200% = 880 gpd (USE NEW 1,5000 TANK) WELL:MIW-29 ZONE: A LOAMY SAND 10YR 3/2 LENGTH 48 NOTE: UNIT CONFIGURATION AND AVAILABILITY SUBJECT LEVEL: 7.8 ADJUSTMENT: 1.4 10.60 B 6" EFFECTIVE LENGTH 4$" TO CHANGE WITHOUT NOTICE. PRODUCT DETAIL MAY LEACHING AREA REQUIRED: (440) = 594.49 S.F. USE BOH ALLOWED ADJUSTMENT OF 1.0' DIFFER SLIGHTLY FROM ACTUAL PRODUCT APPEARANCE. GROUNDWATER OBSERVED AT 104" EL. 2.43 SIDE WALL HEIGHT 3.3" ,74 LOAMY SAND ADJUSTED GROUNDWATER AT EL 3.43 1018 6/8 OVERALL HEIGHT 8" DISTRIBUTION BOX: (4 OUTLETS (MINIMUM)) 8.27 C1 34" OVERALL WIDTH 34" PRIMARY S.A.S. MEDIUM - USE 4 ROWS OF 8 - INFILTRATOR QUICK 4 STD LP (3.3" INVERT) COARSE SAND PERI TEST 2.5Y 6/4 o EL. 6.60 CAPACITY UNITS WITH NO STONE 1.10 120" PROPOSED SEPTIC SYSTEM/SITE PLAN BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF OF CHAMBER) 4 LEEWARD RUN, SOUTH YARMOUTH, MA (CHAMBER UNITS) 32 UNITS x 4.00 LF x 4.73 SF/LF = 605.44 SF PERC RATE <2 MIN/IN. ("Cl" HORIZON) Prepared for: Myers TOTAL AREA = 605.44 SF DESIGN FLOW PROVIDED: 0.74GPD/SF(605.44SF) = 448.0 GPD > 440 GPD req'd Design and Site Plan by: SCALE DRAWN MEYER& SONS, INC. NTS D.M.M. * 1, Darren M. Meyer, R.S., CSE, hereby certify that I am currently approved by MADEP pursuant to 310 CMR 15.017 PO BOX 961 DATE: CHECKED SHEET NO. to conduct soil evaluations and that the above analysis has been performed by me consistent with the EASTSANDW/CH, MA 02537 requirements of 310 CMR 15.017. 1 further certify that I have passed the Soil Eval. Exam in October, 1999. 508-362-2922 05/02/14 D.M.M. 2 Of 2