Loading...
HomeMy WebLinkAboutEngineered Plans - 2014I G� EXIST. 1,000 GAL:\ SEPTIC TANK 14, EXIST. 1,000 GAL LEACH PIT 14� GAR. 17.2 I FI;FNn SOUTH YARMOUTH PROPOSED CONTOUR F9 8-1 PROPOSED SPOT GRADE c -- gg -- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE 00.00% W— EXISTING WATER SERVICE LOCUS. TEST;IT f 115 CAPT BE 0.3G ACKES Yarmouth Health Department 1 _ APPROVED _ y BED ROOM LIV ROOM nn KIT BA TH BED ROOM BED ROOM 59-- 13.3 rd TBM = EL. 17.G BULKHEAD FOUNDATION ,o -- IG 14 Name Date M ma 5-- ZO- 1A GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO STARTING WORK. 10. EXISTING LEACH PIT TO BE PUMPED, CRUSHED AND REMOVED PER TITLE 5. REPLACE WITH CLEAN MEDIUM SAND PER TITLE 5, IF REQUIRED. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY 13. NO KNOWN PRIVATE WELLS WITHIN 150 FT. OF PROPOSED LEACHING 14. ALL PIPING TO BE 4" SCH 40 ® 1 /8"/FT (UNLESS SPEC. ) 15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER 16. NO WETLANDS WITHIN 150 FT. OF PROPOSED LEACHING (r IR@IEgw[lb i. 212014 SCALE: 1"=20' LOCUS MAP LOCUS INFORMATION PARCEL ID: MAP 077 PAR. 012 TITLE REF: 22944/214 PROPERTY IS WITHIN ZONE OF CONTRITBUTION SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 115 CAPTAIN BESSE ROAD SOUTH YARMOUTH, MA PREPARED FOR READY ROOTER EXC. MAY 21, 2014 OF Mt YtK No. 1140 MEYER & SONS, INC. P.O. BOX 981 EAST SANDWICH, MA. 02537 (508)362-2922 SHEET 1 OF 2 J##1540 NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS SEPTIC TANK PROPOSED D -BOX T.O.F. EL.=18.4 INSTALL RISERS & COVERS OVER INLET & INSTALL RISER & COVER OUTLET AND SET TO 6" OF FINISH GRADE SET TO 6" OF GRADE • F.G. EL.=17.0± F.G. EL.=16.80± F.G. EL: 15.70± 9" MIN COVER/ 36" MAX COVER L = 30' ® S=1% (MIN.) EL. = 15.82 0 S=1% (MIN.) 4"SCH40 PVC 4"SCH40 PVC 10"1 14" fi\ I INV.=14.8 48" LIQUID INV.= 14.55 LEVEL } GAS BAFFLE J % \ INV.= 14. EXISTING 1,000 GALLON SEPTIC TANK I EXIST. SEWER OUTLET I NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION 2) D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2) 3) REPLACE EXISTING 1,000 GALLON SEPTIC TANK WITH 1500 GALLON SEPTIC TANK IF FAILED, DAMAGED, OR UNDERSIZED. 4) INSTALL INLET & OUTLET TEES W/ GAS RAFFI F AS RFntIIRFn DESIGN CRITERIA L = 1O'(MAX) 0 S=1% (MIN.) 4"SCH40 PVC 11.3" TO INVERT INV.= 13.00- PROP05ED D -BOX INV.=13.80 DB -5 H 0 BREAKOUT=TOP ELEV.=13.39 INV. ELEV.= 13.00 BOTTOM ELEV.= 12.06 NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL:13.39 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. PROPOSED S.A.S. INSTALL A 4" DIAMETER INSPECTION PORT OVER ONE CHAMBER (MIN.) AND SET TO 3" OF F.G. /-F.G. EL: 15.0(MAX.) INSTALL TWO INSPECTION PORTS (MIN.) 4 ROWS OF 4 UNITS AT 6.25'/UNIT = 25.0'/ROW SOIL ABSORPTION SYSTEM (PROFILE) RESTORE VEGETATIVE COVER BACKFILL WITH CLEAN PERC SAND TO TOP OF CHAMBERS EXISTING SUITABLE 2.83' I MATERIAL 5' MIN. ABOVE BOTTOM OF T.P. EXCAVATION OR G.W. EFFECTIVE WIDTH = 4 x 2.83' = 11.32 (7.76' PROVIDED) USE 4 ROWS OF 4 -HIGH CAPACITY BOTTOM OF TESTHOLE: EL: 4.30 = INFILTRATOR (H20) UNITS -NO STONE SEPTIC SYSTEM PROFILE N.T.S. NUMBER OF BEDROOMS: 3 BEDROOM DESIGN DESIGN FLOW: RESIDENTIAL: 3 BEDROOMS ® 110 GPD/BR = 330 GPD DESIGN PERCOLATION RATE: <2 MIN/IN SOIL TEXTURAL CLASS: CLASS 1 (0.74 GPD/SF) GARBAGE GRINDER: NO (not designed for garbage grinder) DISTRIBUTION BOX: USE DB -5 (H20) SEPTIC TANK: 330 gpd x 200% = 660 gpd USE EXIST. 1,000G SEPTIC TANK LEACHING AREA REQUIRED: (330)/.74 = 445.94 S.F. PRIMARY S.A.S. USE 4 ROWS OF 4 - HI -CAP INFILTRATOR H-20 UNITS -NO STONE BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF OF CHAMBER) (CHAMBER) it UNITS x 6.25 LF x 4.73 SF/LF = 473.00 SF TYPICAL SECTION N.T.S. SOIL LOGS DATE: MAY 14, 2014 SOIL EVALUATOR: DARREN MEYER, CSE 1614 WITNESS: PHIL RENAUD, YARMOUTH HEALTH Elev. TP -1 Depth 15.8 0" A LOAMY SAND t0YR 3/1 i 5.22 7" B LOAMY SAND 10YR 6/8 13.13 C 32" PERC TEST FINE SAND 0 11.55 2.5Y 6/6 9.13 80„ C2 MEDIUM TOTAL AREA = 473.00 SF SAND DESIGN FLOW PROVIDED: 0.74GPD/SF(473.00SF) = 350 GPD > 330 GPD req'd 2.5Y 7/2 4.30 138" PERC RATE <2 MIN/IN. (-Cl- HORIZON) NO GROUNDWATER OBSERVED ' I, Darren M. Meyer, R.S., CSE, hereby certify that I am currently approved by MADEP pursuant to 310 CMR 15.017 to conduct soil evaluations and that the above analysis has been performed by me consistent with the requirements of 310 CMR 15.017. 1 further certify that I have passed the Soil Evol. Exam in October, 1999. o DARREN M. s C> M,EYER', k' No. 1140 �'FGISIE��� SOI TA0 „v vcn , HEIGHT END CAP INFILTRATOR - HI CAPACITY (H20) CHAMBER PROPOSED SEPTIC SYSTEM UPGRADE PLAN 115 CAPTAIN BESSE ROAD, SOUTH YARMOUTH, MA Prepared for: Ready Rooter Exc. Design by: Survey by: SCALE DRAWN DATE MEYER &SONS, INC. Weller and Assoc. N.T.S. DMM 05/21/14 Po BOX 981 508-775-0735 EAST SANDWICH, MA 02537 CHECKED SHEET NO. 508-362-2922 DMM 2 of 2