GENERAL NOTES: 0.28 ACRES
1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL
BOARD OF HEALTH AND THE DESIGN ENGINEER.
2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS
OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE
LOCAL RULES AND REGULATIONS.
3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR
TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE
DESIGN ENGINEER.
4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING
FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN
ENGINEER BEFORE CONSTRUCTION CONTINUES.
5. ALL ELEVATIONS BASED ON ASSUMED DATUM.
6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF
THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF
HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION.
7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE.
PROPOSED CONTOUR
8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED
PROPOSED SPOT GRADE
TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR.
EXISTING CONTOUR
9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE
EXISTING SPOT GRADE
LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO STARTING WORK.
EXISTING WATER SERVICE
BED
10. EXISTING LEACH PITS TO BE PUMPED, CRUSHED AND REMOVED PER TITLE 5.
REPLACE WITH CLEAN MEDIUM SAND PER TITLE 5.
ROOM
11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION
12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY
AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY
13, NO KNOWN PRIVATE WELLS WITHIN 150 FT. OF PROPOSED LEACHING
BED
14. ALL PIPING TO BE 4" SCH 40 0 1 /8"/FT (UNLESS SPEC. )
ROOM BATH
15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW
FOR THE USE OF A GARBAGE GRINDER
16. NO WETLANDS WITHIN 150 FT. OF PROPOSED LEACHING
17. PROPOSED PRECAST 1,500 CAN BE SUBSTITUTED WITH A POLYETHYLENE
TANK IF NECESSARY.
LEGEND
TBM = EL. 40.0
STOOP 5 LAB @
\/9 BUILDING
38
/
/37.
O' ' ?
4Z /
4�' ; 38.7 /
,
9
�'X37.8 t3 G
38.G V
i
7.0
35.1 PROP. 1,500 GAL 34
SEPTIC TANK
i
Ll V
ROOM FAM
ROOM
I!NWNjI,GI KIT
ROOM
SUN
ROOM
FLOOR PLAN
GAR.
34'
�,e--
SCALE: 1"=20'
YARMOUTH
LOCUS MAP
LOCUS INFORMATION
PARCEL ID: MAP 123 PAR. 087
TITLE REF: 10730/289
PROPERTY IS NOT WITHIN ZONE OF CONTRITBUTION
SEPTIC SYSTEM
REPAIR PLAN
LOCATED AT:
46 SQUIRREL RUN
YARMOUTH, MA
PREPARED FOR
CHANNING DUPOUY
MAY 21, 2014
OF MAss�
c3 DARKEN, M. �✓
b�tYER 4-
No. 1140
MEYER & SONS, INC.
P.O. BOX 981
EAST SANDWICH, MA. 02537
(508)362-2922
SHEET 1 OF 2 J#1540
PROPOSED CONTOUR
9®
PROPOSED SPOT GRADE
--98--
EXISTING CONTOUR
+ 96.52
EXISTING SPOT GRADE
W—
EXISTING WATER SERVICE
TEST PIT
TBM = EL. 40.0
STOOP 5 LAB @
\/9 BUILDING
38
/
/37.
O' ' ?
4Z /
4�' ; 38.7 /
,
9
�'X37.8 t3 G
38.G V
i
7.0
35.1 PROP. 1,500 GAL 34
SEPTIC TANK
i
Ll V
ROOM FAM
ROOM
I!NWNjI,GI KIT
ROOM
SUN
ROOM
FLOOR PLAN
GAR.
34'
�,e--
SCALE: 1"=20'
YARMOUTH
LOCUS MAP
LOCUS INFORMATION
PARCEL ID: MAP 123 PAR. 087
TITLE REF: 10730/289
PROPERTY IS NOT WITHIN ZONE OF CONTRITBUTION
SEPTIC SYSTEM
REPAIR PLAN
LOCATED AT:
46 SQUIRREL RUN
YARMOUTH, MA
PREPARED FOR
CHANNING DUPOUY
MAY 21, 2014
OF MAss�
c3 DARKEN, M. �✓
b�tYER 4-
No. 1140
MEYER & SONS, INC.
P.O. BOX 981
EAST SANDWICH, MA. 02537
(508)362-2922
SHEET 1 OF 2 J#1540