Loading...
HomeMy WebLinkAboutEngineered Plans - Rev. 1999LOT 41 C. g '1 d. by BENCHAlARK l00.0 ASSUNEDJ CORN R OF :ONCRETE STEP , soh N77049 55 ,)' E nn 200 94:5 ASSESSORS - - 94.5 \ 1 \ LOT S42 \ \ , AREA = 18000 1 \SQ FT. ✓ / q 2918,DECK 1 W GARAGE tag d. h. sss� 60 d 3 S M II \ c� c� \ \ �� L HSE. 1 ' \O 1 1 0\ tv 122 � 11 `\ � � O b � \\ I I o 9 5' w �� /-�'krsTrNc ELE g4. o I \ a \ \ wv \ / -BOX 1�" -9dls or O �_\ s �p EL.=100 B \ �a ft7UNDAT/ONu� �cH , C nn 00 30.9' - �y C. . ' J db, LOT 43 NOTES. 1. PUMP CRUSH & FILL EXISTING LEACH PITS 2. REMOVE EXISTING DIB. GRAPHIC SCALE 30 0 15 30 60 OF PAUL yG� A. MEF rrH&v No. 32W8 �FC►ST�Q\ OF WILLIAM GN, LIEBERMM �. � No. 23911 120 1 inch = 3u it. �/J,- 4 LOCUS RE'S. ZONE. "R-40 " FLOOD ZONE: "C" PLAN REF 221/5 ASSESSORS MAP 58 SEPTIC REPAIR PROJEC T L OCA TION 22 SKYLINE WEST YARMC APPLICANT - DA VID AND YANKEE SUR l/t P.O. UNI T 1, 408 MARS TONS M, PH. (508)428— 0055 [S_CALE.• 1 30' REV.• 9/7/99 JOB NO. 22SKY 1) 2) 3) 4) 5) 1, 6) 7) 8) 9) 10) — 100.8_ ?YIP OF FYJUNDATION 20' MIN. CONCRETE COVERS EXISTING GALLONS SEPTIC TANK PROFILE SEWAGE DISPOSAL NOT TO SCALE GENERAL NOTES OF SYSTEM ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO DER TITLE 5 AND THE TOWN OF _�i_RMQ.U1T__I _____ RULES AND REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE. ONE COVER ON SEPTIC TANK SHALL BE BROUGHT TO WITHIN 6" OF FINISHED GRADE, OTHERS WITHIN 12" ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL BE MORTERED IN PLACE. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER/APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCA VATION CONTRACTOR IS TO CALL "DIG- SAFE" AT 1-600-322-4844 AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. PARCEL IS IN FLOOD ZONE __"C"_____ LOT IS SHOWN ON ASSESSORS MAP 5B AS PARCEL _ s42 PUMP AND FILL CESSPOOLS. 4' SCHEDULE 40 P. VC MIN. PFl H 1/8 PER FT. CONCRETE COVER DIS'llelHUTION BOX TO BE WATER TESTED IF MORE THAN ONE OUTLET PLACE ON 6" STONE 3/4" 710 1 -112 - NO 2"LAYER OF 1/8"-1/2" WASHED SYVNE \ EL = 96.5' (3' X 6.25' X 1. 33) 11' X 38' TRENCH MAM4TION SOIL ABSORPTION SYSTEM (SAS) 10" EFF DEPTH USGS PROBABLE WATER TABLE ELEV.=_ 8_8.25_ OBSERVED WATER TABLE (2/23/99) ELEV.= 8825 _ ASSUMED WATER TABLE ELEV. = 8525 OBSERVATION HOLE I ELEV = 9_6.5 _ PERCOLATION RATE _< ? MINI INCH AT 3s"+12" INCHES DEPTH HORIZ TEXTURE COLOR MOTT. OTHER 0-8" A SIL 10 YR 5/2 NONE 8p"-36" B S 10 YR 5/6 NONE MED 36 "- 72 l Cl S 10 YR 6/6 NONE MED 72"'_123pj C2 S 10 YR 5/6 NONE MED DAMP AT 120"—NO WATER ENCOUNTERED AT 123" DATE OF SOIL WITNESSED BY ASSUMED WATER TABLE +12" AT 135" 3 HOLES SIDE BY SIDE A) 4--6- HAND AUGER TO 123- B) 3'0 HOLE TO 72" C) PERK HOLE AT 36'148- WATER 6'%48" WATER TABLE ADJUSTMENT 3.1' A VERA GE OF A & B ZONES PROPERTY ON ZONE LINE TEST 8/5/99 SOIL TEST DONE BY A7LLIAM LIEBERMAN BRUCE MURPHY Y. B. 0. H. SOIL EVALUATOR DESIGN CALCULA TIONS.• TOP LOAD 5 HIGH CAPACITY INFILTRATORS KTH 4' DOUBLE WASHED �_2 SIDES AND ENDS11'X38'� WILLIAM LIEBERMAN , No. 2337 t NUMBER OF BEDROOMS . . . . . . . . GARBAGE DISPOSAL . . . . . . . . . TOTAL ESTIMATED FLOW 3 NO ( 110__GAL/BR./DAY x 3___ BR) 330 GAL/DAY REQUIRED SEPTIC TANK CAPACITY 1000 GAL (REPAIR) SOIL CLASSIFICATION . . . . . . . . I SAS DESIGN PERCOLATION RATE . . . . . < 2 -MIN./IN. EFFLUENT LOADING RATE . . . . . . • 74 GAL/DA Y/S. F. LEACHING CAPACITY (AREA X RATE) 369 GAL/DAY 1---, RESERVE LEACHING CAPACITY . . . 369 GAL/DAY (38XI1X. 74)+(38+38+11+IIX 74XIO112) SHEET 2 0 2 JOB NUMBER _22.SKY___ FE