Loading...
HomeMy WebLinkAboutEngineered Plans - 2014LOCUS DATA CURRENT OWNER PHILLIP WOODMAN PATRICIA WOODMAN PLAN REFERENCE LCP 39064-8 DEED REFERENCE CTF 166713 ZONING DISTRICT R-40 FLOOD ZONE "C" ASSESSORS MAP 46 PARCEL 30 OVERLAY DISTRICT ZONE II LOT AREA 23,096± S.F. SITE 8c SEWAGE UPGRADE�REPAIR PLAN 215 H/GG/NS CRO WELL ROAD IN W. YARMOUTH, MASS DATE: JUNE 26, 2014 OWNER/APPLICANT: PHILLIP & PATRICIA WOODMAN 34 HIGHCREST PARK WEBSTER, MA 01570 SHEET 1 OF 2 PREPARED BY: EAS SURVEY, INC. P.O. BOX 1729 SANDWICH, MA 02563 PH. (508) 888-3619 CELL (508) 527-3600 EAS.SURVEY@YAHOO.COM ImIX43 Iw►lririlLei : s • .,I KITCHEN I BED#1 V-A 0,1 Lp �I Ln a OPEN TO BELOW nBATH BED#2 BED#3 sx 1 P VED ame Date Iw to N W Z4V r ` J o R, E 128.62' 0o. SECOND FLOOR N -71' At) 2" EXISTING SEPTIC COMPONENTS T0; B PUMPED, CRUSHED AND ABANDONED IN ACCORDANCE WITH TITLE 5. yy� o rr, } I , PROPOSED} RISER } D.T.H. #1 } DECK > LOT 7 23,096± S.F. BENCHMARK CORNER OF CONCRETE BULKHEAD. ELEV.=31.00 #215 EXISTING DWELLING 33.4' \ PROPOSED 1,500 GALLON 1 SEPTIC TANK. O, 00 < PROPOSED i 3 .J 13.0'x25.0' `1 L C) -7 LEACHING S.A.S. _I `�� r 154.99... S 71 .15' 44.5' 11 6, N O 0 LA o f o. w w C9S EXISTING DRIVEWAY � C9S �9s HORSE PON N LOCUS 9 Z BUCK ISLAND ROAD 0 r� r r 0 D 28 LOCUS MAP NOT TO SCALE: 11 i� N O rn W 0 20 30 40 "° o ao � o GRAPHIC SCALE: 1 INCH = 20 FEET Q) ,e��\ EDWARD A. STONE No.94 fcI XE RD. m L vv 14-0117 TOP OF FOUNDATION ELEV. 31.72 FINISH GRADE ELEV. 30.6 T AISE COVERS TO WITHIN 6" OF FINISH GRADE RAISE ONE RISER FINISH GRADE TO WITHIN 6" 30.7OF FINISH GRADE ELEV. 30.8 i6'05=0.02 4'®S=0.015 SCH 40 - 4 PVC 2 MIEN=3 M qX 4" PVC SCH 40 6' ®S= 0.01 O INV.= INV.= 28.22 27.90 10"TEE 14"TEEINV.= No 5-7" INSTALL 27.70 6" O GAS BAFFLE 3 OUTLET 4'-6 1/2 4'-1" LIQUID LEVEL H-10 DB3 INV.= 27.64 INV.= 27.47 0 0 0, 0 0 BOT 24.36 6" BASE OF CRUSHED STONE OR MECHANICALLY COMPACTED 1,500 GALLON PRECAST CONCRETE SEPTIC TANK JOB # 14-0117 SITE &SEWAGE UPGRADE/REPAIR PLAN 215 HI GGINS CROWELL ROAD IN W. YARMOUTH, MASS DATE: JUNE 26, 2014 OWNER/APPLICANT: PHILLIP & PATRICIA WOODMAN 34 HIGHCREST PARK WEBSTER, MA 01570 SHEET 2 OF 2 PREPARED BY: EAS SURVEY, INC. P.O. BOX 1729 SANDWICH, MA 02563 PH. (508) 888-3619 CELL (508) 527-3600 EAS. SU R VEY@YAH 00. COM 0000 0 \-QJ o 00000 O O o 0loo 0 0000 0 0 0000 TWO 5' -0"x8' -6"x2'-10" CHAMBERS ,INV.= 27.41 >: Ww S.A.S. (13.0' x 25.0') a � 00 ui ui CONSTRUCTION NOTES: 1. CONTRACTORS / INSTALLERS SHALL VERIFY GRADES AND ELEVATIONS AND SITE CONDITIONS PRIOR TO COMMENCING WORK ON THE SITE. 2. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 3. ENGINEER TO VERIFY REMOVAL OF UNSUITABLE SOILS PRIOR TO INSTALLATION OF NEW SEPTIC SYSTEM. 4. NO PARKING OVER SEPTIC TANK IS ALLOWED. GENERAL NOTES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE V AND THE TOWN OF YARMOUTH RULES AND REGULATIONS FOR SUBSURFACE DISPOSAL OF SEWERAGE. 2. AT LEAST ONE ACCESS POINT OVER TANK TEES SHALL BE ACCESSIBLE WITHIN 3" OF FINISH GRADE, WITH ANY REMAINING ACCESS PORTS BROUGHT TO WITHIN 12" OF FINISH GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS OTHERWISE SPECIFIED. 4. THE EXCAVATION CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTILITIES PRIOR TO ANY EXCAVATION. 5. ANY MASONRY UNITS USED TO BRING COVERS TO GRADE OR WITHIN 6" OF GRADE SHALL BE MORTARED IN PLACE. 6. FINISH GRADE SHALL HAVE A MINIMUM OF 0.02 FEET PER FOOT OVER THE S.A.S. AND DISTRIBUTION BOX. 7. SEPTIC TANK SANITARY TEE'S SHALL BE CONSTRUCTED OF SCHEDULE 40 PVC AND SHALL EXTEND A MINIMUM OF 6" ABOVE THE FLOW LINE AND SHALL BE ON THE CENTERLINE AND LOCATED DIRECTLY UNDER THE CLEAN OUT MANHOLES. 8. THE INLET PIPE INVERT ELEVATION SHALL BE NO LESS THAN 2 INCHES NOR MORE THAN 3 INCHES ABOVE THE INVERT ELEVATION OF THE OUTLET PIPE. 9. THE SEPTIC TANK SHALL HAVE A MINIMUM COVER OF 9 INCHES 10. THE OUTLET SANITARY TEE SHALL BE EQUIPPED WITH A GAS BAFFLE, 4 INCHES IN DIAMETER AND CONSTRUCTED OF 4" PVC 11. ALL PIPES SHALL BE SCHEDULE 40 PVC SEWER PIPE AND SHALL BE SLOPED 1/4 INCH PER FOOT MIN. EXCEPT FOR THE FIRST TWO FEET OUT OF THE DISTRIBUTION BOX WHICH SHALL BE LEVEL 12. CHANGES OR REVISIONS TO SEPTIC DESIGN REQUIRE NOTIFICATION TO EAS SURVEY INC. FOR B.O.H. AND DESIGN ENGINEERS REVIEW AND APPROVAL. 13. MAGNETIC TAPE ON ALL COMPONENTS. 31.0 1' MIN. -3' MAX. COVER 0 T N 25.41 20.4 ••••• ••••• 4.0' 5.0' 13.0' SIDE VIEW DATUM: VERTICAL DATUM: YARMOUTH GIS± BENCH MARK USED: CORNER OF CONCRETE BULKHEAD ELEVATION 31.00 DTH #1} INDICATES DEEP TEST HOLE -oo- 132" INDICATES ADJ. GROUNDWATI ==* _ NO OBSERVED GROUNDWATER INDICATES PERC TEST 48" SYSTEM DESIGN DESIGN FLOW 3 BEDROOMS AT110 GPB/D IN- GPD REQUIRED SEPTIC TANK 330 x-2 = _____660 GAL. PROPOSED SEPTIC TANK = 11500 -GAL. SIZE OF LEACHING FACILITY REQUIRED DESIGN PERC RATE <2 �v11N./INCH LONG TERM APPL. RATE-2.-14--GPD/S.F. GROUNDWATER ADJUSTMENT DEPTH TO BOTTOM OF HOLE 11.0' VARIANCES REQUESTED NONE SIZE OF LEACHING SYSTEM PROVIDED: 330 _ 0.74 SF/GPD = _446 S.F. MIN. REQ. USING H-10 CONCRETE LEACHING CHAMBERS WITH 4' OF STONE ALL AROUND BOTTOM (13.0' x 25.0') = 325 S.F. SIDE WALL (13.0' + 25.0') 2x2 = 152 S.F 477 S.F. 477 S.F.x 0.74 G/SF = 353 GPD 353 GPD PROV > 330 GPD REQ. = 23 GPD RES. NO (GARBAGE DISPOSAL / GRINDER ALLOWED) D.T.H. #1 0 DATE: JUNE 19, 2014 GROUND ELEV. 31.4 ADJ G.WATER 20.4 A/E LOAMY SAND 10YR 5/1 4„ e LOAMY SAND 7.5YR 6/6 24" ELEV = 29.4 48" C MEDIUM SAND 2.5Y 7/6 132" NO G.WATER ELEV = 20.4 B.O.H. AMY VON HONE SOIL EVALUATOR ED. STONE BACKHOE OPERATOR. ELLIS BROTHERS (KEVIN) SOIL TYPE: -_ PERC RATE: <2 MIN. PER INCH LOADING RATE: 0_74 GAL/SF/MIN