Loading...
HomeMy WebLinkAboutEngineered Plans - 2014A" 12.3 91 / A. / 13.j� Parking / / Area 412.6 / 6 13.0 tK //• \%Yoe 13.4 11.3 Install Clean a Out tK \1.5 \ guy O \ \ Util. Pole 1 1 SCAL E: 7 " 20' 0 20' 40' 60' BENCHMARK: EI. 14.25 On North—East Door Threshold TH 12A7 o /� oN neas'� ? i3AIrt1�L cs� CIVIL No. 46253 �pfi fiC' 1 i T ti¢'$• �� rS10NAL PROPOSED LEACHING FIELD 30.5' LONG BY 9.0' WIDE 3—ROWS OF 4—CULTEC CONTACTOR 10OHD (STONELESS 3.2 PROPOSED 1500 GAL SEPTIC TANK Sh t: I o f2 Living Bedrm Rm Bedrm Bedrm n Kitchen Dining EXIST. FLOOR LAYOUT Lawn Box 4" Screw Cap Cultec Perforated Pipe Chamber Inside Chamber Use min.: 2-3/8" Holes ® 2" vert.spacin_g SAS INSP. PORT DETAIL ..jauth Health Department P VED :L ame Date Locus 0 e o'S 6Q Q, \ Pay r Rd t/) \ °e �o ( Ra \ Lewis Lewis Pond I L_ Bay_ Seo Gull 0 LOCATION MAP Assessors Map 7 7 Parcel 47 Deed: Bk.2194 7, Pg.227 Plan: Bk.58, Pg.21, Lot 20 SAS CONSTRUCTION DETAIL *Use Cultec 470 Filter Fabric over Chambers & *Use Clean Around and Medium Sand for 6" Above hambers 4—Cultec 700HD Chambers 30.5' H OF Wc"��� cti��,. ORAN ENGINEER f �1 ING ASSOC.,LLC LAir)Uc No. 3)7560 .CCG 941 MAIN STREET (RTE 28), HARWICH, MA 0 6 S S k / 12.3 PLAN IN YARMOUTH M wood Deck Richord & Vanda Farnham OA 1 L/ EXISTING PROJECT: 74-056 SCALE: 7 " 20' 1 DATE.• 5/5/74 HOUSE TOF EI 13.53 LOT 20 11 7 N O 6,514.16 SF t I d 0 0.15 AC J PLAN Bk 58 Pg 21 BH d 12.8 12.7 \ � \ �0 Q) 11.3 Install Clean a Out tK \1.5 \ guy O \ \ Util. Pole 1 1 SCAL E: 7 " 20' 0 20' 40' 60' BENCHMARK: EI. 14.25 On North—East Door Threshold TH 12A7 o /� oN neas'� ? i3AIrt1�L cs� CIVIL No. 46253 �pfi fiC' 1 i T ti¢'$• �� rS10NAL PROPOSED LEACHING FIELD 30.5' LONG BY 9.0' WIDE 3—ROWS OF 4—CULTEC CONTACTOR 10OHD (STONELESS 3.2 PROPOSED 1500 GAL SEPTIC TANK Sh t: I o f2 Living Bedrm Rm Bedrm Bedrm n Kitchen Dining EXIST. FLOOR LAYOUT Lawn Box 4" Screw Cap Cultec Perforated Pipe Chamber Inside Chamber Use min.: 2-3/8" Holes ® 2" vert.spacin_g SAS INSP. PORT DETAIL ..jauth Health Department P VED :L ame Date Locus 0 e o'S 6Q Q, \ Pay r Rd t/) \ °e �o ( Ra \ Lewis Lewis Pond I L_ Bay_ Seo Gull 0 LOCATION MAP Assessors Map 7 7 Parcel 47 Deed: Bk.2194 7, Pg.227 Plan: Bk.58, Pg.21, Lot 20 SAS CONSTRUCTION DETAIL *Use Cultec 470 Filter Fabric over Chambers & *Use Clean Around and Medium Sand for 6" Above hambers 4—Cultec 700HD Chambers 30.5' H OF Wc"��� cti��,. ORAN ENGINEER f �1 ING ASSOC.,LLC LAir)Uc No. 3)7560 508-432-2878 941 MAIN STREET (RTE 28), HARWICH, MA 0 6 S S k SEPTIC SYSTEM DESIGN PLAN IN YARMOUTH Prepared For: Richord & Vanda Farnham OA 1 L/ PROJECT: 74-056 SCALE: 7 " 20' 1 DATE.• 5/5/74 ELEV. 13.1 11.9 10.3 5.6 2.6 SEPTIC TANK EL 13.10 13.53 1 ra'OF COVERS TO BE WITHIN 6' OF GRADE FOUNDATION I 1 ALSO 3' MIN SEL 11.3 39' t 4- 10.6 LJ1 GALLEON 4I 10 NsrALL BAFFLE 6' OF STONE UNDER TANK EL 10.4 SEPTIC TANK NOTES 1. Extend inlet tee 10" min. below flow line; extend outlet tee 14" below flow line. 2. Provide 20" access over center of tank, inlet, and outlet with readily removable impermeable covers. 3, Install access port over inlet and outlet with precast concrete or equivalent watertight riser within 6" min. of final grade. DATE: 4/9/14 DEEP OBERVA77ON HOLE # 1 TEST Br: RICK JUDD TIME: 01:00 FromCOLOR Surface HOR. TEXTURE (NUN TELL) SOIL MOTTLING STRUCTURE CONSISTENCY, OTHER 14" Ap Sandy Loam 10YR3 2 NO granular 34" Bw Loamy Medium Sand 10YR4 4 NO very friable 90" C1 Medium Sand 2.5YR6 4 NO loose, single grain 126" C2 Fine Medium Sand 2.5M7/3 NO loose, sin ie grain L 1 GWE 1 126" Bot. of Perc: 30" RATE: < 2 MIN/INCH: Class I Soil Loading Rate (0.74 gpd/sf): WITNESS: Amy Von Hone, Yarmouth Health Department ESTIMATED HIGH GROUNDWATER CALCULATION (USGS/CCS METHOD) INDEX WELL: #_ MTW-29 _ ZONE: __ A DATE OF READING:__4/14__ INDEX WELL DEPTH TO GROUNDWATER: 7.84__ GROUNDWATER LEVEL ADJUSTMENT:- 01.5 ACTUAL GROUNDWATER LEVEL ® SITE EL= __-02.6 ESTIMATED (MAX) HIGH GROUNDWATER LEVEL EL= __04.1 0 2014 Moran Engineering Associates, LLC. 8' t 9$ » X 10' f MAXIMUM 1. Install outlet pipes level 2 feet minimum. 2. Provide a minimum sump of 6" below outlet invert. 3. Install access port over "D" Box with precast concrete or equivalent watertight riser within 6" min. of final grade. 1. REQUIRED FLOW: 3 -BEDROOMS X 110 GPD/B.R.= 330 -GPD 2. SEPTIC TANK CAPACITY: 330 GPD X 2 = 660 -GPD USE 1500 -GALLON SEPTIC TANK . 3. LEACH FACILITY DESIGN: 12-CULTEC CONTACTOR 10OHD (3 ROWS OF 4-UNITS)=91.5 LF 91.5 LF. X *5.0 SF/LF = 457.5 SF. 457.5 SF. X 0.74 CPD/SF = 338.5 GPD. 338.5 GPD PROVIDED > 330 GPD REQUIRED *Per Mass.DEP Certification For General Use USE: 3 ROWS OF 4-CULTEC CONTACTOR 10OHD. SET CHAMBERS SIDE BY SIDE. COVER ENTIRE FIELD WITH CULTEC 410 FILTER FABRIC. BACKFILL TO THE TOP OF COMPONENTS WITH CLEAN TITLE 5 FILL. PROVIDE THREE INSPECTION PORTS PER PLAN. INSPECTION PORTS ARE REQUIRED TO HAVE IRRIGATION CONTROL BOXES COVERS TO GRADE., NAT FILTER TITLE 5 AP. R LEACH FACILITY Irrigation CULTEC CONTACTOR 10OHD Control Box-- 4" or 6' PVC PULL CAP, END CAP. END PLUG OR CLEANOUT. 6' SCH. 40 PVC OR MIN 2% SLOPE / SDR -35 PVC PIPE RISER MIN. 9' COVER MAX 36' COVER INSPECTION PORTS (3) FILTER FABRIC 7.5' EACH UNIT (INSTALLED) 30.5' LENGTH INSTALLED 5.2' EL 4.1 ADJUSTED GROUND WATER ELEVATION NOTES FOR CULTEC 1.) Must be a Cert.Cultec Installer. 2.) Cultec No. 410 Filter Fabric or equal approved by Cultec required. GENERAL NOTES *Existing Sewer Elevation & Location Is To Be Verified Prior To The Installation Of Any New Component. 1.) ALL SYSTEM COMPONENTS SHALL BE INSTALLED IN ACCORDANCE W/ITTLE 5 OF THE SANITARY CODE & ANY APPLICABLE REGULATIONS. 2.) PRIOR TO BACK FILLING THE INSTALLATION, THE SANITARIAN & HEALTH AGENT SHALL BE NOTIFIED FOR INSPECTION. 3.) ANY ALTERATIONS OF THIS DESIGN MUST BE APPROVED BY THE SANITATION & BOARD OF HEALTH, IN WRITING. 4.) SYSTEM IS NOT DESIGNED FOR A GARBAGE GRINDER. 5.) THE INSTALLER IS TO VERIFY THE LOCATIONS) OF UTILITIES, CESSPOOL(S) AND SEWER INVERTS PRIOR TO CONSTRUCTION. 6.) ALL UNSUITABLE MATERIAL WITHIN 5 FT. IN ALL DIRECTIONS FROM THE SOIL ABSORPTION SYSTEM SHALL BE REMOVED & REPLACED W/CLEAN, COARSE SAND. 7.) ALL FILL MATERIAL UTILMED FOR THE SOIL ABSORPTION SYSTEM SHALL BE CLEAN, COARSE SAND FREE FROM DELETERIOUS MATERIAL AND SHALL HAVE A PERCOLATION RATE OF LESS THAT 2 MIN./Iid. BEFORE & AFTER PLACEMENT. 8.) EXISTING CESSPOOL(S) TO BE PUMPED AND BACK FILLED PER TITLE 5 ABANDONMENT PROCEDURES. 9.) DURING INSTALLATION, THE CONTRACTOR IS RESPONSIBLE TO PROVIDE A SAFE EXCAVATION AREA. 10.) GROUND COVER OVER SEPTIC SYSTEM COMPONENTS SHALL NOT EXCEED 36". 11.) ALL GRAVITY SEWER PIPE SHALL BE 4" DIA. SCH 40 PVC UNLESS OTHERWISE NOTED. THE MINIMUM SLOPE OF 4" DIA. SCH 40 PVC SHALL NOT BE LESS THEN 0.01 FT/FT. 12.) WHEREVER SEPTIC LINES CROSS WATER SERVICE LINES OR WHEN WATER SERVICE LINES COME WITHIN 10' OF THE PROPOSED S.A.S.- PIPES SHALL BE CLASS 150 PRESSURE PIPE & SHOULD BE PRESSURE TESTED TO ASSURE WATER TIGHTNESS. COORDINATE WITH LOCAL WATER DEPARTMENT. 13.) PLACE MAGNETIC MARKING TAPE OVER ALL COMPONENTS. CONSTRUCTION NOTES 1.) Contact office (508) 432-2878 a minimum of 2 days prior to start of project. 2.) Pump and remove the existing cesspool - Inspection required. 3.) Raise septic tank covers (2) and distribution box cover to within 6" of final grade. Raise 3- inspection ports, with irrigation covers, to finished grade. 4.) A soil inspection is required prior to placement of leaching components: contact office 48 -hours in advance. Title 5 fill (clean sand) is required to be placed along and over the Cultec units. Cover to top of chambers with Title 5 fill. 5.) Final grade is not to exceed 36" over leaching area. All final landscape details are to be between the owner and septic installer. Sh t: 20 f2 1 40 Lorena Road, Yarmouth, MA I Richard & Vanda Farnham Assess�xs MAP: 17 Parcel: 47 Not to Scale DATE: 5/5/14 SHEET 2 of 2 Moran Engineering Associates, LLC 941 Main 5t., Harwich, MA PO Box 183, 5. Harwich, MA 02661 508-432-2878