Loading...
HomeMy WebLinkAboutEngineered Plan - 2014Perm ONL' Boari any sewal LEGEND N PARTIAL STRIPOUT SEE NOTE 11 ROP° s 98 - EXISTING CONTOUR4) t� x 98,98 EXISTING SPOT GRADE c �°!� EXISTING S.A.S. -- g9 -- PROPOSED CONTOUR p o � LOCUS CONVENTIONALLY SIZED REMOVE AS REQUIRED FOR STRIPOUT AND TO MAINTAIN STRUCTURAL INTEGRITY -W EXISTING WATER SVC. 4 -G EXISTING GAS SVC. BUCK ISLAND RD OF ADJACENT DRIVEWAY '"1> --0.%/: W. --OVERHEAD WIRES 4 0 TEST PIT G F 17.85 BENCHMARK 19.97 21,22 20,45 j Swan 1� J x x 2b.84 110.00, ���y Pond 2 1 �'-�--� ; X1,22 ' LOCUS MAP 20,04 N n I I 1-I -1 x JO' 21.34 PATIO p I PRq_ SHE9� NOT TO SCALE .J �. x _ I-�� I I I PA TIO 21,23 GENERAL NOTES: 20,- 119 10 T IIP 2� ( 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 18,45 101 EXISTING 2• ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS 1 HOUSE(J34)LOCAL 21. 2 OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE 20.6 RULES AND REGULATIONS. I I T.O.F.=22.71- -310 CMR 15.405(1)(b): 1) An 1' variance, S.A.S. to cellar wall, for a 19' setback. 18,8 pAVFD 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR L._ _I TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE PK SET N DESIGN ENGINEER. 18,87 �\ _ p , 21,11 Q a? C) 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN SAWCUT PAVEMENT19,32y WALK N ENGINEER BEFORE CONSTRUCTION CONTINUES. FOR NEW PAVEMENT 5. ALL ELEVATIONS BASED ON THE REFERENCED BENCHMARK OFTHE 20 53 21.26 ' O ®0@� F APPROVED PLAN ON FILE ENTITLED, "TITLE 5 SITE PLAN" BY DOWN EXISTING SEPTIC TANK CAPE ENGINEERING, DATED MAY 13, 2002. REFERENCE BENCHMARK �a 2 - _ TOP OF TANK, EL.=20.0611- IS TOP OF HYDRANT TAG BOLT, EL.=22.31 (HYDRANT #1025). INV. (OUT)=18.56f(VERIFY) 0g� WSO � T 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF valid for REPAIR OF SEPTIC SYSTEM 19.85 0,69 20,82 THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. due to State and local septic -variances. Of Health review and approval is required for o, Q /`� 0.12 / 20,74 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. hoe additions/renovations/alterations to(� 1289 8. THERE ARE NO PRIVATE WELLS WITHIN 100' OF THE PROPOSED S.A.S. 19,81 facilities and/or structures/dwelling. ove /Dy�ent 9, ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS BY OWNER AND CONTRACTOR OR AS OTHERWISE Varmouth lkalth Department 20.13 � 20.06 AGREED UPON DIRECTED BY THE APPROVING AUTHORITIES. APPROVED S�'��� A � LOT 30� P 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING APN 48-39.2 L� 9,483± F CONSTRUCTION. 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND `• f'K 20.17 SET REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). Date 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE Benchmark Set INSPECTED BY HEALTH DEPTARTMENT PRIOR TO BACKFILL, TOP OF WATER SHUT-OFF 13. THE ENGINEER IS NOT RESPOSBLE FOR ANY UNDOCUMENTED SEPTIC OF SYSTEM COMPONENTS NOT SHOWN ON THE PLAN. ��� Mgss9 EL. 19.85 (See Note 5) 14. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND Gam, � 1 •$ IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY. PETET. o R MCENTEE PROPOSED SEPTIC SYSTEM UPGRADE PLAN o CIVIL No, 35109 34 CIRCUIT ROAD NORTH, WEST YARMOUTH, MA �£PSZE��� `� FLOOR PLAN ON FILE Prepared for: Stephen Crowley, 34 Circuit Road North, West Yarmouth, MA 02673 S E OWNER OF RECORD Engineering by: SCALE DRAWN JOB. No, STEPHEN J CROWLEY Engineering Works, Inc. 1 "=20' P.T.M. 144-14 l 34 CIRCUIT ROAD NORTH 12 West Crossfield Road, Forestdale, MA 02644 DATE CHECKED SHEET No. WEST YARMOUTH, MA 02673 (508) 477-5313 5/14/14 P.T.M. 1 of 2 NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL.18.28 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. SEPTIC TANK PROPOSED D -BOX PROPOSED S.A.S. INSTALL RISERS & COVERS OVER INLET & INSTALL RISER & WATERTIGHT INSTALL 1 INSPECTION PORT(MIN.) -- - - OUTLET AND SET TO 6" OF FINISH GRADE COVER SET TO 6" OF GRADE AT END OF S.A.S. T.O.F.=22.7± POSEDI 27,7, F.G. EL.=21.1 t EXISITNG F.G. EL.=21.Ot F.G. EL.=20.6± F.G. EL.=20.6± N I S. S. I 1° I 15 I , MAINTAIN 2% GRADE (MIN.) OVER S.A.S. I I 0 9 7�F�XMINiKl' f INSPECTION PORT HOUSE 34 i# L = 12'(MAX.) p�' 38 2 3 ® S=1% (MIN.) 0 S=1% (MIN.) ONE (MIN.) 9' T.O.F.=22.7± 4"SCH40 PVC 4"SCH40 PVC To° 14' s^ 7.13" TO Cn EXISITNG 48" LIQUID - INVERT I I PK SET t LEVEL GASBAFFLEINV.=18.09 PROPOSED r- INV,=17.92 (6 ROWS OF 3 UNITS AT 5,0'/UNIT) + 1.2' (1 COUPLER) = 16.2' 18.87 'ILP, -P INV,=18.56± D -BOX SOIL ABSORPTION SYSTEM EXISITNG SEPTIC TANK EXISITNG (PROFILE) H-20 INV.=17.80 ESTABLISH VEGETATIVE COVER BACKFILL WITH CLEAN NATIVE OR PERC SAND TO TOP OF CHAMBERS wso "% 19,85 BREAKOUT=TOP �' TOP ELEV.= NOTES; INV. ELEV.=17.80 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS, PRIOR TO INSTALLATION, BOTTOM ELEV.=17.20- S.A.S. LAYOUT 2) D -BOX SHALL BE SET LEVEL AND TRUE TO 2,83' GRADE ON A MECHANICALLY COMPACTED SIX 5' MIN. ABOVE BOTTOM OF INCH CRUSHED STONE BASE, AS SPECIFIED IN T.P. EXCAVATION OR G.W. EFFECTIVE WIDTH=17.0' Note: Arc 36 SIDE PORT H-10 COUPLERS ARE TO BE 310 CMR 15.221(2). EXISTING SUITABLE 3) INSTALL INLET & OUTLET TEES AS REQUIRED. ADJUSTED G.W., EL=12.2 _ MATERIAL ALSO USED WITH THIS DESIGN. 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE 63.5" AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. USE 6 ROWS OF 3 -ADS Arc 36 UNITS + 1 COUPLER PER ROW WITH NO SEPARATION BETWEEN EACH ROW & NO STONE - SEPTIC SYSTEM PROFILE TYPICAL SECTION t3„ 9' F N.T.S. 33.8" DESIGN CRITERIA SOIL LOG 4 DATE: MAY 8, 2014 NUMBER OF BEDROOMS: 3 BEDROOMS SOIL EVALUATOR: PETER McENTEE (SE#1542) TOP VIEW WITNESS: PHIL RENAUD - HEALTH AGENT SOIL TEXTURAL CLASS: CLASS I Elev. TP __- 60" DESIGN PERCOLATION RATE: <2 MIN/IN Depth END CAP END CAP 20.6 0 FRONT VIEW SIDE VIEW hok" DAILY FLOW: 330 GPD FILL END CAP DESIGN FLOW: 330 GPD 19.9 10" REAR/TOP VIEW A GARBAGE GRINDER: NO-S.A.S. IS NOT DESIGNED FOR GARBAGE GRINDER LOAMY SAND NOTE: UNIT CONFIGURATION AND AVAILABILITY SUBJECT SIDE VIEW 1 OYR 4/2 19.3 14" TO CHANGE WITHOUT NOTICE. PRODUCT DETAIL MAY DIFFER SLIGH�TLLY FROM ACTUAL PRODUCT APPEARANCE. LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF B GPD/SF LOAMY SND r 4640 , BLVD 0 .74 0YR 5 / 18.6 24 OHIO 6 s HIILL ARDr)s Arc 36 DETAIL kk EXISITNG SEPTIC TANK: 1500 GALLON CAPACITY C' ADVANCED DRAINAGE SYSTEMS, INC. PROPOSED D -BOX: 1 INLET, 5 OUTLET (MINIMUM), H-20 RATED F, PERC 44"/56" PROPOSED SEPTIC SYSTEM UPGRADE PLAN USE 6 ROWS OF 3 -ADS Arc 36 UNITS + 1 COUPLER PER F -M SAND 34 CIRCUIT ROAD NORTH, WEST YARMOUTH, MA ROW WITH NO SEPARATION BETWEEN EACH ROW & NO STONE 2.5Y 6/6 BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.80 SF/LF OF UNIT) 12.2 ADJ. G.W. ,r Prepared for: Stephen Crowley, 34 Circuit Road North, West Yarmouth, MA 02673 (Arc36 Units) 18 UNITS x 5.0 LF x 4.80 SF/LF = 432.0 SF 10.8 STG. G.W. V 118" Engineering by: SCALE DRAWN JOB. NO. (COUPLERS) 6 COUPLERS x 1.17' x 4.80 SF/LF = 33,7 SF 10.4 122" En g g Works, Inc. ineerin N.T.S. P.T.M. 144-14 TOTAL AREA = 465.7 SF STANDING G.W. ® 118" (EL.=10.8) - DESIGN FLOW PROVIDED: 0.74 GPD/SF(465.7 SF) = 344.6 GPD INDEX WELL, MIW-29, ZONE A, ADJUSTMENT= 1.4', APRIL 2014 12 West Crossfield Road, Forestdole, MA 02644 DATE CHECKED SHEET NO. PERC RATE 2 MIN/IN. ("C" HORIZON) (508) 477-5313 5/14/14 P.T.M. 2 Of 2