HomeMy WebLinkAboutEngineered Plans - 2008PLYMOUTH ROAD SECTION DETAIL LEGEND --}-/� PROPOSED CONTOUR ® PROPOSED SPOT GRADE --98 — — EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE W— EXISTING WATER SERVICE TEST PIT .Existing Leach Pit (Note 10) Existing 1,000 gal Fem-it valid for REPAIR OF SEPTIC SYSTEM ONLY, due to St _!c a;;d Local septic variances. Board of Health revictiv and approval is required for any future additions/renovationstalterations to selvage facilities and/or structures/dwelling. Yarmouth Health Department APPROVED sa4a,4 NO DWELLINGS WITHIN 20 FT. OF PROPOSED LEACHING. Dote MAP 144 LOT.- 11.9 GENERAL NOTES. 1 LOCUS MAP N.T.S. 1, ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW: - 310 CMR 15.405 (1) (A): 1) A 5 FT. VARIANCE FROM 310 CMR 15.211 TO ALLOW LEACHING TO BE 5 FT. FROM PROPERTY LINE VS. REQUIRED 10 FEET. 2) UP TO A 1.0 FT. VARIANCE FROM 310 CMR 15.211 TO ALLOW LEACHING TO BE UP TO 4.0 FT BELOW GRADE VS REQ'D 3 FT. (H20/VENT PROVIDED) 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER, 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 10. EXISTING LEACH PIT TO BE PUMPED, CRUSHED AND FILLED. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATIONS 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY ASI i l - 13. NO PRIVATE WELLS WITHIN 150' OF PROPOSED LEACHING. 14. NO WETLANDS WITHIN 150' OF PROPOSED LEACHING. HEALTH DE 15, ALL PIPING TO BE 4" SCH 40 0 1 /8"/FT (UNLESS SPECIFIED) 16. INSTALLER TO TAKE MEASURES TO PREVENT VEHICULAR TRAFFIC OVER LEACHING. PROPOSED SEPTIC SYSTEM UPGRADE PLAN 33 PLYMOUTH ROAD, YARMOUTHPORT, MA Prepared for: Mike Dedecko _ Engineering by: Surveying by: SCALE DRAWN JOB. N0, DARRENM. Il4EYER. R. S. Weller and Assoc. 1 "=20' DMM PO BOX 881 Route 28 — EASTSANDWICH, MA02.537 Centerville, MA 02632 DATE CHECKED SHEET NO. 508-362-2922 (508) 775-0735 08/13/08 DMM 1 of 2 4FU bA IOt « ': C 1 � � _Havnflorne Ad '� ' `� et fta t� GENERAL NOTES. 1 LOCUS MAP N.T.S. 1, ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW: - 310 CMR 15.405 (1) (A): 1) A 5 FT. VARIANCE FROM 310 CMR 15.211 TO ALLOW LEACHING TO BE 5 FT. FROM PROPERTY LINE VS. REQUIRED 10 FEET. 2) UP TO A 1.0 FT. VARIANCE FROM 310 CMR 15.211 TO ALLOW LEACHING TO BE UP TO 4.0 FT BELOW GRADE VS REQ'D 3 FT. (H20/VENT PROVIDED) 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER, 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 10. EXISTING LEACH PIT TO BE PUMPED, CRUSHED AND FILLED. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATIONS 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY ASI i l - 13. NO PRIVATE WELLS WITHIN 150' OF PROPOSED LEACHING. 14. NO WETLANDS WITHIN 150' OF PROPOSED LEACHING. HEALTH DE 15, ALL PIPING TO BE 4" SCH 40 0 1 /8"/FT (UNLESS SPECIFIED) 16. INSTALLER TO TAKE MEASURES TO PREVENT VEHICULAR TRAFFIC OVER LEACHING. PROPOSED SEPTIC SYSTEM UPGRADE PLAN 33 PLYMOUTH ROAD, YARMOUTHPORT, MA Prepared for: Mike Dedecko _ Engineering by: Surveying by: SCALE DRAWN JOB. N0, DARRENM. Il4EYER. R. S. Weller and Assoc. 1 "=20' DMM PO BOX 881 Route 28 — EASTSANDWICH, MA02.537 Centerville, MA 02632 DATE CHECKED SHEET NO. 508-362-2922 (508) 775-0735 08/13/08 DMM 1 of 2