Loading...
HomeMy WebLinkAboutEngineered Plans - 201425.1 EXIST. CE55POOL5 (SEE NOTE 1 O) O 5 . ICO o•_ F- f1kialliN 3.7 HSE # 5413 TBM TO.F.@ EL. 24.5 1 L23.G vent a G 1 24. PROP. 1,500 GAL SEPTIC TANK .22 ACRE5 +/- ,WATER ��-_�RVi�E Permit valid for R6' AIR t>1�' SEPTIC SYSTEM ONLY, due to St, and l,ucal septic variances. Board of Ilealth rev ew and approval is required for any future add ions/rends ations/aIterations to _ sewage facilities as /or structures/dwelling. t\ _ N arty th I}ealth 0cpartment YYRt) -- 1z /Z7, V e Name +24.9 C\/ +25.0 lim 24.3 Th BM = EL. 24.0 - OP OF BOTTOM STEP `7 -" 7 fes" Date +23.5 I 23.� zn, + 23.3 + 0 23.0 + 23.5 2 1 .4 22.5 22:2 --f-21.5 +20.5 193 20.2 LEGEND PROPOSED CONTOUR ® PROPOSED SPOT GRADE --98 -- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE W- EXISTING WATER SERVICE & TEST PIT GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS, EXCEPT AS NOTED BELOW. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO STARTING WORK. 10. EXISTING CESSPOOLS TO BE PUMPED, CRUSHED AND REMOVED PER TITLE (LOCATIONS ARE APPROXIMATE) 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY 13. NO KNOWN PRIVATE WELLS WITHIN 150 FT, OF PROPOSED LEACHING 14. ALL PIPING TO BE 4" SCH 40 ® 1/8"/FT (UNLESS SPEC.) 15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER 16. NO WETLANDS WITHIN 150 FT. OF PROPOSED LEACHING MAXIMUM FEASIBLE COMPLIANCE - VARIANCES - 310 CMR 15.405 (1) (B) AND DENNIS BOH REGULATIONS: A 6 FT. VARIANCE FROM 310CMR15.211 TO ALLOW LEACHING TO BE 14 FT FROM DWELLING VS REQ'D 20 FT. - 310 CMR 15.405 (1) (B) AND DENNIS BOH REGULATIONS: A 0.56 FT. VARIANCE FROM 310CMR15.211 TO ALLOW LEACHING TO BE 3.56 FT BELOW GRADE VS REQ'D 3 FT. (VENT PROVIDED) SOUTH DENNIS LOCUS MAP LOCUS INFORMATION TITLE REF: BK: 872 PG: 002 PARCEL ID: MAP 50 PAR. 99 SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 54 B FOREST ROAD SOUTH YARMOUTH, MA PREPARED FOR BANKS/FERNS AUGUST 29, 2014 SCALE: 1"=20' O Fo DARREN tyl s No. 1140 SANITAR\P MEYER 8c SONS, INC. P.O. BOX 981 EAST SANDWICH, MA. 02537 (508)362-2922 SHEET 1 OF 2 J#1588 NOTE: TO PREVENT BREAKOUT, THE PROPOSED NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS FINISH GRADE SHALL NOT BE < EL:20.74 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. f 10 OMgsXq� SEPTIC TANK PROPOSED D -BOX PROPOSED S.A.S. T.O.F. EL.=24.5 INSTALL RISERS & COVERS OVER INLET & INSTALL RISER & COVER " INSTALL A 4DIAMETER INSPECTION PORT OVER �. ; o DARRE{J OUTLET AND SET TO 6" OF FINISH GRADE SET TO 6" OF GRADE ONE CHAMBER (MIN.) AND SET TO 3" OF F.G. vENT MEYER ' F.G. EL.=24.01 F.G. EL.=24.3f F.G. EL: 24.5f F.G. EL: 24.30(MAX.) `��'� I� No. 1140 9" MIN COVER/ L = 30' 36" MAX COVER L = 18' 0 S=1% (MIN.) L = 10'(MAX) INSTALL TWO INSPECTION PORTS (MIN.) SANITAR�a� EL. 38.0 @ S=1% (MIN.) 4"SCH40 PVC 4'SCH40 PVC 0 S=1% (MIN.) 4"SCH40 PVC3. f, "+ I V 10'1 14 6 11.3" TO INV.=21 .90 4e" LIQUID INV.=20.85 IN VERT INV.=20.35 LEVEL PROPOSED GAS BAFFLE D -BOX 3 ROWS OF 5 UNITS AT 6.25'/UNIT + 0.75' WEDGE = 32.0'/ROW INV.=20.45 INV.=20.65 DB -5 SOIL ABSORPTION SYSTEM (PROFILE) PROPOSED 1.500 GALLON SEPTIC TANK EXISTING SEWER OUTLET RESTORE VEGETATIVE COVER EL. 22.50 BACKFILL WITH CLEAN PERC SAND TO TOP OF CHAMBERS 75" NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING BREAKOUT=TOP ELEV.=20.74 PIPE INVERTS PRIOR TO CONSTRUCTION INV. ELEV.= 20.35 2) TANK AND D -BOX SHALL BE SET LEVEL AND TRUE BOTTOM ELEV.= 19.41 EXISTING SUITABLE TO GRADE ON A MECHANICALLY COMPACTED SIX2 83' MATERIAL INCH CRUSHED STONE BASE, AS SPECIFIED IN 5' MIN. ABOVE BOTTOM OF 76 - 310 CMR 15.221(2) T.P. EXCAVATION OR G.W. EFFECTIVE WIDTH = 3 x 2.83' = 8.49' 3) INSTALL INLET & OUTLET TEES W/ (6.41' PROVIDED) USE 3 ROWS OF 5 -HIGH CAPACITY PROFILE GAS BAFFLE AS REQUIRED BOTTOM OF TESTHOLE EL.=13.0 -_ ADS 1620BD BIODIFFUSER (H20) UNITS -NO STONE 4) PRECAST SEPTIC TANK MAY BE REPLACED WITH A POLYETHYLENE TANK AS NEEDED, MUST MEET W/ CONTOURED WEDGE f 15.226(2)(). SEPTIC SYSTEM PROFILE TYPICAL SECTION�- 16" N.T.S. N.T.S. 11 2„ - A SOIL LOG **NO PROPOSED INCREASE IN FLOW** DESIGN CRITERIA DATE: JULY 30, 2014---34"--�) SOIL EVALUATOR: DARREN M. MEYER, R.S., CSE #1614 SECTION END CAP NUMBER OF BEDROOMS: 3 BEDROOM DESIGN WITNESS: AMY VONHONE, YARMOUTH HEALTH SOIL TEXTURAL CLASS: CLASS I DESIGN PERCOLATION RATE: <2 MIN/IN Elev. TP -1 16" HIGH CAPACITY 1620BD (H-20) BIODIFFUSER UNIT DAILY FLOW: 110 G.P.D/BR. DESIGN FLOW: 330 G.P.D. Depth 24.30 0" MODEL 16" HICAP GARBAGE GRINDER: NO (NOT DESIGNED FOR GARBAGE GRINDER) A LOAMY �D LENGTH 76" gpd x 200 = 1485 d USE PROPOSED 1,500 GALLON SEPTIC TANK: 330 gp SEPTIC TANK 23'72 7' B NOTE: UNIT CONFIGURATION AND AVAILABILITY SUBJECT EFFECTIVE LENGTH 75' LOAMY SANDTO 10YR 6/8 CHANGE WITHOUT NOTICE. PRODUCT DETAIL MAY 21 80 30" DIFFER SLIGHTLY FROM ACTUAL PRODUCT APPEARANCE. SIDE WALL HEIGHT 11.3" C MEDIUM LEACHING AREA REQUIRED: (330)/0.74 = 445.94 S.F. PERC TEST SAND OVERALL HEIGHT 16" DISTRIBUTION BOX: 3 OUTLETS (MINIMUM) 20.30 9 2.5Y 7/4 4640 TRUEMAN BLVD §9406 OVE�2ALL WIDTH133" 19.89 53„ NlLLIARD, OHIO 43026 6 CF PRIMARY S.A.S. C2 USE 3 ROWS OF 5 - 16' ADS 16208D BIODIFFUSER H-20 UNITS -NO STONE FINE SAND 25Y 7/2 CAPACITY (101.7 GAL) ADVANCED DRAINAGE SYSTEMS, INC. AND EXTENDED 0.75' W/ CONTOURED WEDGES PROPOSED SEPTIC SYSTEM/SITE PLAN BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF OF BIODIFFUSER) (BIODIFFUSERS) 15 UNITS x 6.25 LF x 4.73 SF/LF = 443.43 SF 13.0 136" 54B FOREST ROAD, SOUTH YARMOUTH, MA (CONTOURED WEDGE) 3 ROWS x 0.75' x 4.73 SF/LF = 10.64 SF PERC RATE <2 MIN/IN. SOILS IN ("C" HORIZON) Prepared for: Banks/Ferns TOTAL AREA = 454.07 SF Engineering and Surveying by: Meyer& Sons, Inc. SCALE NTS DRAWN D.M.M. DATE: 08/29/14 DESIGN FLOW PROVIDED: 0.74GPD/SF(454.07SF) = 336.01 GPD > 330 GPD req'd NO GROUNDWATER OBSERVED ' I, Darren M. Meyer, R.S., CSE, hereby certify that 1 am currently approved by MADEP pursuant to 310 CMR 15.017 PO BOX 981 REV. DATE: CHECKED to conduct soil evaluations and that the above analysis has been performed by me consistent with the EASTSANDWICH, MA 02537 SHEET N0. requirements of 310 CMR 15.017. 1 further certify that I have passed the Soil Eval. Exam in October, 1999. 508-362-2922 D.M.M. 2 of 2