Permit valid for REPAIR OF SEPTIC SVS'I EM
ONLY, due to State anti Local septic variances.
Board of Ilealth review and approval is required for
any future additions/reit,,%ations/;aiterations to
sewage facilities and/or structures/dwelling.
Varmouth Health I)epartmcnt
APPROVED/.
� C
C� - 2-8- Iq
GENERAL NOTES: 3G
1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL O
BOARD OF HEALTH AND THE DESIGN ENGINEER.
2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS I�
OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE
LOCAL RULES AND REGULATIONS.
3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR
TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE
DESIGN ENGINEER.
4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING
FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN
ENGINEER BEFORE CONSTRUCTION CONTINUES.
5. ALL ELEVATIONS BASED ON ASSUMED DATUM.
6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF
THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF
HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION.
7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE.
8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED
TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR.
9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE
LOCATION OF ALL UNDERGROUND UTILITIES. PRIOR TO STARTING WORK.
10. EXISTING LEACH PITS TO BE PUMPED, CRUSHED AND REMOVED PER TITLE 5.
REPLACE WITH CLEAN MEDIUM SAND PER TITLE 5.
11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION
12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY
AND IS NOT TO BE CONSIDERED A PROPERTY UNE SURVEY
13. NO KNOWN PRIVATE WELLS WITHIN 150 FT. OF PROPOSED LEACHING
14. ALL PIPING TO BE 4" SCH 40 ® 1 /8"/FT (UNLESS SPEC. )
15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW
FOR THE USE OF A GARBAGE GRINDER
16. NO WETLANDS WITHIN 150 FT. OF PROPOSED LEACHING
17. PROPOSED PRECAST 1,500 CAN BE SUBSTITUTED WITH A POLYETHYLENE
TANK IF NECESSARY.
S
3 OF,.
LEGEND
PROPOSED CONTOUR
® PROPOSED SPOT GRADE
__98 - - EXISTING CONTOUR
+ 96.52 EXISTING SPOT GRADE
W- EXISTING WATER SERVICE
S TEST PIT
37.2`\
E 7
RATE _ \
\7� 39.2 ,
�G
i
,nF_n
39.
39.5
G r I 32.00
flo
3G
37.3
39.5
S'
O\
PROP. i ,500 GAL
SEPTIC TANK
Q (S� 10 M a �, 39.4 EX15T. LEACH PIT
o o (NOTE 10)
38k'j
ven MAXIMUM FEASIBLE COMPLIANCE - VARIANCES
39. - 310 CMR 15.405 (1) (B):
A 1 FT. VARIANCE FROM 310CMR15.211 TO ALLOW SEPTIC TANK
TO BE 5 FT FROM DWELLING VS REQ'D 10 FT.
310 CMR 15.405 (1) (B):
A 2 FT. VARIANCE FROM 310CMR15.211 TO ALLOW LEACHING TO BE 18 FT. FROM FULL
FOUNDATION VS. REQ'D 20 FT. AND 9 FT. FROM SLAB VS REQUIRED 10 FT.
310 CMR 15.405 (1) (A):
A 2 FT. VARIANCE FROM 310CMR15.211 TO ALLOW SEPTIC TANK
TO BE A MINIMUM OF 6 FT FROM FRONT PROPERTY UNE VS REQ'D 10 FT.
310 CMR 15.405 (1) (A):
A 2 FT. VARIANCE FROM 310CMR15.211 TO ALLOW LEACHING
TO BE A MINIMUM OF 6 FT FROM FRONT PROPERTY UNE VS REQ'D 10 FT. (NO FOUND W/IN 20')
- 310 CMR 15.405 (1) (A):
A 1.13 FT. VARIANCE FROM 310CMR15.211 TO ALLOW LEACHING TO BE 4.13 FT BELOW GRADE
VS. REQ'O 3 FT. (VENT/H20 PROVDIED)
YARMOUTH
LOCUS MAP
LOCUS INFORMATION
PARCEL ID: MAP 091 PAR. 032
TITLE REF: 16944/258
PROPERTY IS WITHIN ZONE OF CONTRITBUTION
SEPTIC SYSTEM
REPAIR PLAN
LOCATED AT:
15 PAR THREE DR.
YARMOUTH, MA
PREPARED FOR
RICHARD O'NEILL
SEPTEMBER 28, 2014
OF Mgs,q�y�
�
MEYER
S1 " No. 1140
STFD )
SANITAit�P� G I �I ��'I
MEYER & SONS, INC.
P.O. BOX 981
EAST SANDWICH, MA. 02537
(508)362-2922
SHEET 1 OF 2
540
NOTE:
NOTE: TO PREVENT BREAKOUT, THE
MAGNETIC TAPE TO BE PLACED OVER ALL COVERS FINISH GRADE SHALL NOT BE
PROPOSED
< EL:35.17
Depth
0"
FOR A DISTANCE OF 15' AROUND THE
TOF: EL.=40.0t SEPTIC TANK
PROPOSED D -BOX
PERIMETER OF THE S.A.S.
16"
INSTALL RISERS & COVERS OVER
OUTLET AND SET TO 6" OF FINISH
INLET & INSTALL RISER & COVER
GRADE
PROPOSED S.A.S.
INSTALL A 4" DIAMETER INSPECTION PORT OVER
38.3010YR
F.G. EL.=39.51
SET TO 6" OF GRADE
ONE CHAMBER (MIN.) AND SET TO 3" OF F.G.
VENT
. •: � ` F.G. EL.=39.5t
F.G. EL: 39.31
F.G. EL: 39.30(MAX.)
�`{�y
own
M
9" MIN COVER/
36" MAX COVER
®S=1% (MIN.) EL. - 136.82
4"SCH40 PVC . _ .... .. .
I t4"
INV.=36.15 M. LIQUID -
LEVEL
I GAS BAFFLE
L= 80'
0 SV % (MIN.)
4"SCH40 PVC
INV.=35.90
PROPOSED
D -BOX
INV.=35.05 DB -3
PROPOSED 1.500 GALLON SEPTIC TANK
EXISTING SEWER OUTLET
INV.=36.75
NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING
PIPE INVERTS PRIOR TO CONSTRUCTION
2) TANK AND D -BOX SHALL BE SET LEVEL AND TRUE TO
GRADE ON A MECHANICALLY COMPACTED SIX
INCH CRUSHED STONE BASE, AS SPECIFIED IN
310 CMR 15.221(2)
3) INSTALL INLET" & OUTLET TEES W/
GAS BAFFLE AS REQUIRED
L = 1O'(MAX)I I INSTALL TWO INSPECTION PORTS (MIN.)
0 S=1% (MIN.)
4"SCH40 PVC
11.3" TO
INVERT
INV.=34.78 -
INV.=34.88 3 ROWS OF 5 UNITS AT 6.25'/UNIT + 0.75' WEDGE = 32.0'/ROW
SOIL ABSORPTION SYSTEM (PROFILE
BREAKOUT=TOP ELEV.=35.17*83' INV. ELEV.=34.78
BOTTOM ELEV.--33.84
RESTORE VEGETATIVE COVER
�- BACKFILL WITH CLEAN PERC SAND
TO TOP OF CHAMBERS
EXISTING SUITABLE
MATERIAL
5' MIN. ABOVE BOTTOM OF
T.P. EXCAVATION OR G.W. EFFECTIVE WIDTH = 3 x 2.83' = 8.49'
(5.08' PROVIDED) USE 3 ROWS OF 5 -HIGH CAPACITY
BOTTOM OF TESTHOLE EL.=28.80 = ADS 1620BD BIODIFFUSER (H20) UNITS -NO STONE
W/ CONTOURED WEDGE
SEPTIC SYSTEM PROFILE
TYPICAL SECTION
N.T.S.
SOIL LOG
DATE: SEPTEMBER 10, 2014
SOIL EVALUATOR: DARREN M. MEYER, R.S. CSE 1614
WITNESS: PHIL RENAUD, YARMOUTH HEALTH
PERC RATE <2 MIN/IN. SOILS IN ("C" HORIZON)
NO GROUNDWATER OBSERVED
' I, Darren M. Meyer, R.S., CSE, hereby certify that I am currently approved by MADEP pursuant to 310 CMR 15.017
to conduct soil evaluations and that the above analysis has been performed by me consistent with the
requirements of 310 CMR 15.017. 1 further certify that I have passed the Soil Evol. Exam in October. 1999.
DESIGN CRITERIA
NUMBER OF BEDROOMS: EXISTING 3 BEDROOM DESIGN
SOIL TEXTURAL CLASS: CLASS I DESIGN PERCOLATION RATE: <2 MIN/IN
DAILY FLOW: 110 G.P.D/BR. DESIGN FLOW: 330 G.P.D.
GARBAGE GRINDER: NO (NOT DESIGNED FOR GARBAGE GRINDER)
SEPTIC TANK: 330 gpd x 200% = 660 gpd USE NEW 1,500 GAL SEPT. TANK
LEACHING AREA REQUIRED: (330)/0.74 = 445.94 S.F.
DISTRIBUTION BOX: 3 OUTLETS (MINIMUM)
PRIMARY S.A.S.
USE 3 ROWS OF 5 - 16" ADS 16208D BIODIFFUSER H-20 UNITS
- NO STONE AND EXTENDED 0.75' W/ CONTOURED WEDGES
BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF OF BIODIFFUSER)
(BIODIFFUSERS) 15 UNITS x 6.25 LF x 4.73 SF/LF = 443.43 SF
(CONTOURED WEDGE) 3 ROWS x 0.75' x 4.73 SF/LF = 10.64 SF
TOTAL AREA = 454.07 SF
DESIGN FLOW PROVIDED: 0.74GPD/SF(454.07SF)= 336.01 GPD > 330 GPD req'd
76 "
PROFILE
16"
I r.N
1 34"�
SECTION
END CAP
16" HIGH CAPACITY 1620BD (H-20) BIODIFFUSER UNIT
MODEL
Elev.
TP -1
Depth
0"
75"
39.30
A
OVERALL HEIGHT
16"
LOAMY SAND
34"
CAPACITY
38.3010YR
4/2
12"
9 -LOAMY SAND
10YR 5/6
�F
36.55
33"
o� DARREN M. y�
C
MEYER �
_' ('o.�
MEDIUM
Nd. 1140 '�, "'
SAND
!i !
PERC
2.5Y 7/4
`SNI TARP*
EL.35.30
�'J I d
� 1
28.80
126"
PERC RATE <2 MIN/IN. SOILS IN ("C" HORIZON)
NO GROUNDWATER OBSERVED
' I, Darren M. Meyer, R.S., CSE, hereby certify that I am currently approved by MADEP pursuant to 310 CMR 15.017
to conduct soil evaluations and that the above analysis has been performed by me consistent with the
requirements of 310 CMR 15.017. 1 further certify that I have passed the Soil Evol. Exam in October. 1999.
DESIGN CRITERIA
NUMBER OF BEDROOMS: EXISTING 3 BEDROOM DESIGN
SOIL TEXTURAL CLASS: CLASS I DESIGN PERCOLATION RATE: <2 MIN/IN
DAILY FLOW: 110 G.P.D/BR. DESIGN FLOW: 330 G.P.D.
GARBAGE GRINDER: NO (NOT DESIGNED FOR GARBAGE GRINDER)
SEPTIC TANK: 330 gpd x 200% = 660 gpd USE NEW 1,500 GAL SEPT. TANK
LEACHING AREA REQUIRED: (330)/0.74 = 445.94 S.F.
DISTRIBUTION BOX: 3 OUTLETS (MINIMUM)
PRIMARY S.A.S.
USE 3 ROWS OF 5 - 16" ADS 16208D BIODIFFUSER H-20 UNITS
- NO STONE AND EXTENDED 0.75' W/ CONTOURED WEDGES
BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF OF BIODIFFUSER)
(BIODIFFUSERS) 15 UNITS x 6.25 LF x 4.73 SF/LF = 443.43 SF
(CONTOURED WEDGE) 3 ROWS x 0.75' x 4.73 SF/LF = 10.64 SF
TOTAL AREA = 454.07 SF
DESIGN FLOW PROVIDED: 0.74GPD/SF(454.07SF)= 336.01 GPD > 330 GPD req'd
76 "
PROFILE
16"
I r.N
1 34"�
SECTION
END CAP
16" HIGH CAPACITY 1620BD (H-20) BIODIFFUSER UNIT
MODEL
16" HICAP
LENGTH
76"
EFFECTIVE LENGTH
75"
SIDE WALL HEIGHT
11.3"
OVERALL HEIGHT
16"
OVERALL WIDTH
34"
CAPACITY
13.6 CF
(101.7 GAL)
NOTE: UNIT CONFIGURATION AND AVAILABILITY SUBJECT
TO CHANGE WITHOUT NOTICE. PRODUCT DETAIL MAY
DIFFER SLIGHTLY FROM ACTUAL PRODUCT APPEARANCE.
4640 TRUEMAN BLVD
HILLIARD, OHIO 43026
s
ADVANCED DRAINAGE SYSTEMS, INC.
I PROPOSED SEPTIC SYSTEM/SITE PLAN
15 PAR THREE DRIVE, SOUTH YARMOUTH, MA
Prepared for: O'Neill
Design by: Survey by: SCALE DRAWN DATE:
MEYER& SONS, INC. WellerandAssoc. NTS D.M.M. 09/28/14
PO BOX 981 508-775.0735
E4STSANDWICH,MA02537 CHECKED SHEET NO.
508-362-2922 D.M.M. 2 of 2