Loading...
HomeMy WebLinkAboutEngineered Plan - 2014ACCESS COVERS MUST BE W1 THIN 9 MINIMUM. INVERT ELEVATIONS: OES l GN CR l TER l A . GENERAL NOTES: 6 OF FINISH GRADE 3' MAX/MUM COVER INVERT AT BUILDING: 99.0 DESIGN FLOW 2 BEDROOMS, DESIGN FOR 10/.34 FIRST 2' TO MIN 2" OF PEASTONE INVERTSEPTIC TANK: 98.25 3 BEDROOMS MINIMUM AT 1/0 G.P.D. PER I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION BE LEVEL IN E OR FILTER FABRIC INVERT OUT SEPTIC TANK: 98.0 BEDROOM EQUALS 330 G.P.D. OF THE SEWAGE DISPOSAL SYSTEM ONLY. a' D1AM PIPE3/4 - 1 1/2M DIA. INVERT IN DIST. BOX: 97.37 DOUBLE WASHED STONE INVERT OUT DIST. BOX. 97.2 NO GARBAGE GRINDER 2. VER T I CAL DATUM IS ASSUMED, FOR BENCH MARKS l _ GA 9 0 97.2 2' H-20 �o SET. SEE SI TE PLAN. 95. l INVERT IN LEACH CHAMBER:` 97.1 SEPTIC TANK R UIRED: I 5 `� BAFFLE 7 ��$aD 97.1 SE EQ 3 OUTLET - ACHING CHAMBERS BOTTOM OF LEACH CHAMBER 95.1 2 500 GAL LEACHING 330 G.P.D. X 200: - 660 GAL. 3. ALL CONSTRUCT 1 ON METHODS AND MATERIALS AND D -BOX W14' STONE AROUND. 12.8 ' w x 25 ' I x 2 ' d ADJUSTED GROUND WATER: N/A MAINTENANCE NT NANCE OF THE SEPTIC SYSTEM SHALL SEPTIC .TANK PROVIDED. 1500 GAL. MIN. E 1500 ,GAL H-20 OBSERVED GROUND WATER: N/A CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL SEPTIC TANK 6' CRUSHED STONE OR BOTTOM OF TEST HOLE 89.5 SOIL ABSORPTION SYSTEM REQUIRED: BOARD OF HEALTH REGULATIONS. COMPACTED BASE DES 1 GN PERC RATE l 5 MIN/INCH PROFILE:NOT TO SCALE - SOIL TEXTURAL CLASS - i 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER . EFFLUENT LOADING RATE - 0.74 GPDISF AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER 330- GPD /0. 74 GPDISF - ` 446 S.F. REQUIRED THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. PROVIDED: 2-500 GAL LEACHING CHAMBERS W/4' STONE AROUND. A-471 S.F. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 PVC OR 471 S.F. x 0.74 - 348 G.P.D. APPROVED EQUAL: 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED SOIL TEST PIT DA TA & PRECAST CONCRETE OR APPROVED POLYETHYLENE. UP aBOTH SHALL BE WATERTIGHT. D -BOX SHALL BE WATER C81DH' FND INDICATES " �_ INDICATES PERCOLATION OBSERVED TESTED FOR LEVEL WHEN THERE /S MORE THAN ONE TEST GROUNDWATER OUTLET. - g0.1 0` , l TP #1 7. BEFORE CONSTRUCTION CALL 'DIG -SAFE". oN j, FENCE q gg / 1 -888 -DIC -SAFE AND THE LOCAL WATER DEPT. SToCKAD Il HORIZON TEXTURE COLOR 99 . a --- 0' 100.0 FOR LOCATION OF UNDERGROUND UTILITIES. { - - = 'ESSPOOt FILL ,s PrNE( 8. EXISTING CESSPOOL TO B S E PUMPED DRY AND -------.--- ooh �.; N \ rn - BACKFILLED \ LOAMY IOYR �o 0, SA - A D _ 4o N 5/I - CEss�6oL \ P/ o l%E'2 98.8 /4 P w �y ep�,1 0� o `° �y LOAMY IOYR fPo \o opo i m c'U B SAND 518 oo.zp� ��� 0� ® 32------------------------ 97.3 C I LOAMY FINE IOYR �G \ SAND 7/6 i 16 "PINE 1500 GALLON \yoo4 1, 48" SEPTIC TANK �L�� � I SM. CORNER STEP IYR8 FND EL -101. 0 . psi LOT Ki o �- 12. 120+ S.F. ( o�NO WATER P l 126-'89.5 100.8_ P� / rar. a DATE: AUGUST 28. 2014 ` ( / TES T B Y: S TEPHEN HAAS CATCH BASIN WITNESSED BY: AMY VONHONE EL- 98.59 PERC RATE: C'2 M/NIINCH \ 1 100.5 i \ 25' i u \ a �5H OF MAv a „a..�,a \ 1Q tin M4 . QQV .. .... - .: , .. OD / °++r..c:.c+rrv.wmvr:aa � 1✓ .. !t ,k I diai9 TD T jHealth NN �t WAgNER „<<... pR 8721 2-500 GALLON� 2 99.6 ��.�. � , v*„`. �•t -w � LEACHING CHAMBERS S 7..._--�_. .✓ ,, . -^°, ,,.,<.r;-: W14' :STONE .AROUND � `� .• .,.� .,, � v T_.fix 100.3 � � 9 0 D S 1007 M tJ1- SE7RT l C SYSTE7M DE7S l ON 39 ALM l RA ROAD . MAP 68. PARCEL 97 SOUTH YARMOUTH MA $ AL f RD `r>yT T PREPARED l= 0R LEGEND L D a In CB CONCRETE BOUND WATER LINE SCALE : .. ffi 20 SEPTEMBER 16, 2014 O HYDRANT � �--G GAS L l NE ow OVER A WIRES STEPHEN A . HAAS OHW--- 0 E HEAD > LIGHT POST ENGINEERING, INC -E- UNDERGROUND EL ECTR i C LINE - r = F' 0 . B o x 116 -T- UNDERGROUND TELEPHONE LINE //� ���. S o u t h D e n n i s MA 02660 CT V- 7 UNDERGROUND CABL EV I S I ON LINE GG c.� , /� t �� (SOB) -362-8132 -1- 40.4 SPOT ELEVATION ....... EXISTING CONTOUR LOCUS MAP 0 /0 20 40 40 PROPOSED CONTOUR JOB NO: ` 14-057