Loading...
HomeMy WebLinkAboutEngineered Plans - 2014BED BA TH KIT BREEZE/ ROOM PORCH GAR. BED BED LIV ROOM ROOM ROOM FLOOR PLAN GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 10. EXISTING LEACH PIT TO BE PUMPED, CRUSHED AND REMOVED PER TITLE 5. REPLACE WITH CLEAN MEDIUM SAND PER TITLE 5. 11, 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY 13. NO PRIVATE WELLS WITHIN 150 FT. OF PROPOSED LEACHING 14. ALL PIPE TO BE 4" SCH 40 ® 1 /8"/FT (UNLESS SPEC. OTHERWISE) 15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER 16. NO WETLANDS WITHIN 100 FT. OF PROPOSED LEACHING SOUTH YARMOUTH 0 7; LOCUS: 2 9 CAPTAIN CROCKER RD. co 7- Z A� GPp1 NOES Rp. LOCUS MAP LOCUS INFORMATION TITLE REF: BK 9591 PG 120 PARCEL ID: MAP 078 PAR. 309 PROPERTY IS WITHIN A ZONE II FLOOD ZONE: "C" COMMUNITY PANEL: 250015-0004—C DATED:06/17/86 SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 9 CAPTAIN CROCKER RD, SOUTH YARMOUTH, MA PREPARED FOR GERALD SPITZ MAY 21, 2014 'D R N�M.IN EER.. No. 1140 MEYER & SONS, INC. P.O. BOX 981 EAST SANDWICH, MA. 02537 (508)362-2922 SHEET 1 OF 2 J##1628 LEGEND PROPOSED CONTOUR ® PROPOSED SPOT GRADE -- gg -- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE W— EXISTING WATER SERVICE !� TEST PIT GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 10. EXISTING LEACH PIT TO BE PUMPED, CRUSHED AND REMOVED PER TITLE 5. REPLACE WITH CLEAN MEDIUM SAND PER TITLE 5. 11, 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY 13. NO PRIVATE WELLS WITHIN 150 FT. OF PROPOSED LEACHING 14. ALL PIPE TO BE 4" SCH 40 ® 1 /8"/FT (UNLESS SPEC. OTHERWISE) 15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER 16. NO WETLANDS WITHIN 100 FT. OF PROPOSED LEACHING SOUTH YARMOUTH 0 7; LOCUS: 2 9 CAPTAIN CROCKER RD. co 7- Z A� GPp1 NOES Rp. LOCUS MAP LOCUS INFORMATION TITLE REF: BK 9591 PG 120 PARCEL ID: MAP 078 PAR. 309 PROPERTY IS WITHIN A ZONE II FLOOD ZONE: "C" COMMUNITY PANEL: 250015-0004—C DATED:06/17/86 SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 9 CAPTAIN CROCKER RD, SOUTH YARMOUTH, MA PREPARED FOR GERALD SPITZ MAY 21, 2014 'D R N�M.IN EER.. No. 1140 MEYER & SONS, INC. P.O. BOX 981 EAST SANDWICH, MA. 02537 (508)362-2922 SHEET 1 OF 2 J##1628 NOTE: TO PREVENT BREAKOUT, THE PROPOSED NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS FINISH GRADE SHALL NOT BE < EL:34.35 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. SEPTIC TANK PROPOSED D -BOX PROPOSED S.A.S. T.O.F. EL.=40.0 INSTALL RISERS & COVERS OVER INLET & INSTALL RISER & COVER INSTALL A 4" DIAMETER INSPECTION PORT OVER �F M9S OUTLET AND SET TO 6" OF FINISH GRADE SET TO 6" OF GRADE ONE CHAMBER (MIN.) AND SET TO 3" OF F.G. " F.G. EL=38.5± F.G. EL.=38.4± F.G. EL: 37.5± F.G. EL: 37.35(MAX.) DARREN M. 7325 3ZP>79W0WW -MEYER- No. 1140 9" MIN COVER/ 36" MAX COVER L = 12' ® S=1% L = 10'(MAX) INSTALL TWO INSPECTION PORTS (MIN.) q'FGISTE��� (MIN. EL. = 36.80 � S=1% (MIN.) ® S=1% (MIN.) 4"SCH40 PVC 4"SCH40 PVC 4"SCH40 PVC Sq,yITAR��'� 10"I 14" 6" 3.8" TO INV.= 35.75 4E" LIQUID INV.=35.50 INVERT LEVEL GAS BAFFLE 1 PROPOSED INV.=34.50 4 ROWS OF 5 UNITS AT 5.0'/UNIT = 25.0'/ROW D -BOX INV. =34.7 INV.= 34.0 SOIL ABSORPTION SYSTEM (PROFILE) PROPOSED 1.500 GALLON SEPTIC TANK ,!' j//j _f 60s' RESTORE VEGETATIVE COVER EXISTING SEWER OUTLET BACKFILL WITH CLEAN PERC SAND INV.=37.33 TO TOP OF CHAMBERS NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING BREAKOUT=TOP ELEV.=34.35 34" PIPE INVERTS PRIOR TO CONSTRUCTION= INV. ELEV 34.0 2) TANK AND D -BOX SHALL BE SET LEVEL AND BOTTOM ELEV.= 33.68 EXISTING SUITABLE TRUE TO GRADE ON A MECHANICALLY COMPACTED MATERIAL SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN2.83' 5' MIN. ABOVE BOTTOM OF 310 CMR 15.221(2) T.P. EXCAVATION OR G.W. EFFECTIVE WIDTH = 4 x 2.83' = 11.32 3) INSTALL INLET & OUTLET TEES W / (5.06' PROVIDED USE 4 ROWS OF 5 ARC 36LP PROFILE GAS BAFFLE AS REQUIRED ADJ. GROUNDWATER EL.=28.62 -_ (3.8" INVERT) UNITS -NO STONE 60 " ---1 SEPTIC SYSTEM PROFILE TYPICAL SECTION i N.T.S. N.T.S. SECTION } END CAP DESIGN CRITERIA SOIL LOG NUMBER OF BEDROOMS: 3 BEDROOM DESIGN DATE: MAY 15, 2014 SOIL TEXTURAL CLASS: CLASS I SOIL EVALUATOR: DARREN M. MEYER, R.S., CSE #1614 UNIElevTS DESIGN PERCOLATION RATE: <2 MIN/IN WITNESS: PHIL RENAUD, YARMOUTH HEALTH ARC36 LP (3.8" INVERT) DAILY FLOW: 330 G.P.D. TP -1 Depth 377.1.1 0 A 0" DESIGN FLOW: 330 G.P.D. LOAMY SAND 36.18 1OYR 3/2 11" MODEL ARC 36LP GARBAGE GRINDER: NO (NOT DESIGNED FOR GARBAGE GRINDER) B LOAMY SAND LENGTH 60" PROPOSED SEPTIC TANK: 330 d x 200% = 660 d USE NEW 9p 9p ( 1,50OG TANK ) 34.02 10YR 5/8 37" NOTE: UNIT CONFIGURATION AND AVAILABILITY SUBJECT 60" TO CHANGE WITHOUT NOTICE. PRODUCT DETAIL MAY LEACHING AREA REQUIRED: (330) = 445.94 S.F.SIDE C EFFECTIVE LENGTH DIFFER SLIGHTLY FROM ACTUAL PRODUCT APPEARANCE. WALL HEIGHT 3.8" •74 OVERALL HEIGHT 8" DISTRIBUTION BOX: (5 OUTLETS (MINIMUM)) MEDIUM SAND OVERALL WIDTH 34" 2.5Y 7/3 PRIMARY S.A.S. USE 4 ROWS OF 5 - ARC36LP LOW PROFILE (3.8" INVERT) PER(,O 32.52 -75 PERC6RATE <2 MIN/IN. ("Cl"1 HORIZON) CAPACITY UNITS WITH NO STONE PROPOSED SEPTIC SYSTEM/SITE PLAN BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF OF CHAMBER) FOR TESTHOLE #1: GROUNDWATER OERVED AT 127" EL 26.52 BS 9 CAPTAIN CROCKER ROAD, S0. YARMOUTH, MA CHAMBER UNITS 20 UNITS 5.00 LF 4.73 SF LF = 473 SF ( ) x x SF/LF WELL: MIW-29 ZONE: B Prepared for: Spitz LEVEL: 7,8 ADJUSTMENT: 2.1 ft. TOTAL AREA = 473 SF "ADJUSTED GROUNDWATER ELEVATION 28.62•` Design and Site Plan by: SCALE DRAWN DESIGN FLOW PROVIDED: 0.74GPD/SF(473SF) = 347.8 GPD > 330 GPD req'd MEYER&SONS, INC. NTS D.M.M. t}, ��� j , C • I, Darren M. Meyer, R.S., CSE, hereby certify that I am currently approved by MADEP pursuant to 310 CMR 15.017 PO BOX 961 DATE: CHECKED SHEET NO. to conduct soil evaluations and that the above analysis has been performed by me consistent with the EAST SANDWICH, MA 02537 requirements of 310 CMR 15,017. 1 further certify that I have passed the Soil Eval. Exam in October, 1999. 508-362-2922 05/21/14 D.M.M. 2 of 2