Loading...
HomeMy WebLinkAboutReview Checklist iz -F-/zi- TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. "� Lot / Zone of Contribution: In_ Out Acreag . Commercial: Residential: Street: 3 676'91 U / Village: . tr. a,frit 4,0- Floor Plan: (/ #Bedrooms: Owner: 7 Installer: `./11--, ZO &-ce Address: Phone: 9 Phone: it 5, L/ O V C '?ems I !d :,,,,,,. fi t, Builder: Engineer: ��,I �( Address: Phone: Spg ---P9 2i 77 Phone: /-7( 7/ rti,,. //e4/1'"I N/A YES NO 1.Required#of copies received 2.Date of soils exam and percolation test not older than 2 years i_.----- 3.4-5 /3.4-5 ft of naturally occurring pervious material,above water table c...--- 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: L------ 5.Water line 10 ft from septic components Var.: L.------ 6.Benchmark indicated and shown-NGVD if near wetlands /-/ 7. Septic tank minimum 10 ft from foundation, deck Var.: l 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: t/ 9.Leaching minimum 100 ft from wetlands Var.: �,,---- 10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: t----� 11.Tank/leaching minimum 10 ft from property line Var.: L /' 12. System meets all other setback requirements Var.: L� 13.Uses adjustment for maximum high groundwater Var.: l.---- 14. 14.Leaching set 4-5 ft above adj.water or botto o&estholle Var.: (/ 15.System not in top or subsoil(A,B horizons)or 5'remova L.-------- 16.Proposed contours are suitable .......---- 17. �17. System meets slope requirements-min. 1/8", 1/4"preferred t..------ 18. System meets breakout requirements PVC liner: Wall: 1. --- 19. �19. Specified tee sizes are proper, gas baffle on outlet tee L.----- - 20. Sewage is under 10,000 gpd for parcel c.------- 21.No garbage disposal .t. 22. System adequately sized for its intended use L--/ 23.Minimum 6"stone or compacted below tank and dbox i...--'' 24.Manhole covers within 6"of grade,pump chamber cover to grade L/ 25.Inspection port on plastic chambers/leach field 26.Electrical permit for pump chamber/Separate meter for duplexes V...---- 27. f27.Pump system-2"line,weep hole,check valve,tee in dbox,pump size `-----' 28. Septic tank/pump chamber to be factory waterproofed ,_...---- 29.Vent provided if leaching below 3 feet,under driveway/parking ` .------ 30.Buoyancy calculations for tank/pump chamber l_---, 31.Engineer to inspect and certify soils: wall: commercial: ✓-' 32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33.H-20 loading is subject to vehicular traffic, groundwater ,..----- 34. ./34.Title V Application and permit fee,installer signature l 35.Foundation footing min. 2 feet above adjusted ground water for new house �- 36.Deed Restriction required max. #bedrooms: max. flow: gpd 37. Check area lots for groundwater/Label groundwater in Assessor's Map _/- 6, Plan reviewed by: -,'