Hi dave-
� I have reviewed the plan and have the follawing comments/revisions:
� 1. Show an effluent fiiter in the tank outket because of the pump
1
2. The 2" pressure line, because af the depth of the pump chamber, shpuld be easily accessible without
entering the chamber. Show the 2" iine with a 90 bend in#a the riser with a quick discannect. The line
can exiY the riser or 94 back down into the chamber to exit the outlet opening.
3. Spec#he size of the weep hoie in the pump chamber.
4. Show s check vaive in the pump chamber i'rne.
� 5. Specify that an electrical permit is needed for the pump system.
� Call or ernail with questions.
Thanks, Amy