Loading...
HomeMy WebLinkAboutEngineered Plans - 2015BENCHMARK OUTSIDE COR./STEP EL. =104.34 102,96 OR\J 103.61 10 1. 91 X\ P P�EP� OR�40 102,E AMP O 101.15 CO OWNER OF RECORD GLOVER, CHRISTOPHER M GLOVER, JENNIFER 44 FISHING BROOK ROAD WEST YARMOUTH, MA 02673 x 10343 PLAY + 103,69 AREA • N`L��:. ;\ `A O. / 103,63\�D,p•, 0 TBM 103.59 10 , 4 HOUSE(J44) T. 0. F. =104, O -E 103.05\+ LOT 309 io2,59 11,010±SF MBL 58-234 0 102.11 f� 102,29( \ `\9 FST! GS 100.68 100,64 HOUSE LOCATION TAKEN FROM CERTIFIED PLOT PLAN BY CMS ASSOCIATES, INC., SO. YARMOUTH, MA, DATED 7/30/76 PK SET 100.00 FIRE PI T REL OCA TE ' -I- 101.16 103 4 ��489 `9e- x 9 x� I , 02.15 100,68/ x x J 98 8) D1 0� x 99.33' �� I eaAe 96.75 m LO U J EXISTING SEPTIC TANK TOP OF TANK, EL. =102.86 INV. (OUT)= 98.84.± LEGEND - - 100 - - EXISTING CONTOUR x 100.98 EXISTING SPOT GRADE W EXISTING WATER SERVICE G ----- EXISTING GAS SERVICE -6.H. V/ ----OVERHEAD WIRES TEST PIT BENCHMARK ;�:Ih health Depart-.- : EXISTING LEACH PIT CONTRACTOR SHALL PUMP, FILL WITH SAND & ABANDON N s LOCUS F�� po G0 STREET e` 9Q Q o= e �DU�E 20 0 O�0 28 RD��E LOCUS MAP NOT TO SCALE GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS, EXISTING STORM DRAIN SYSTEM 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR ® TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE 5 GALLEY'S W/3' STONE. ALL SIDES. DESIGN ENGINEER. 95.33 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING x FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN 94.37 ENGINEER BEFORE CONSTRUCTION CONTINUES. / q 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 94. '(1 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF / THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF / 94,49 HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. / O 7. WATER SUPPLIED BY TOWN WATER SERVICE. x,80 8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S. PP, 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS P AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE O BY THE APPROVING AUTHORITIES. 0DIRECTED 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION, 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3), 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE INSPECTED BY A LICENSED SOIL EVALUATOR PRIOR TO BACKFILL. OF Mq 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND CtiG IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY. ��`P o PETER T. 14, EXISTING FLOOR PLAN TO BE PROVIDED BY OWNER. g McENTEE PROPOSED SEPTIC SYSTEM UPGRADE PLAN o CIVIL No. 35109 44 FISHING BROOK ROAD, WEST YARMOUTH, MA A9�F fGIS1E G\ Prepared for: Ca ewide Enterprises, 153 Commercial St., Mashpee, MA 02649 SIONA Engineering by: SCALE DRAWN JOB. NO. Engineering Works, Inc. 1 "=20' P.T.M. 258-14 1ST 12 West Crossfield Road, Forestdale, MA 02644 DATE CHECKED SHEET NO. (508) 477-5313 2/26/15 P.T.M. 1 Of 2 NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL:99.0 SEPTIC TANK FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. INSTALL RISERS & COVERS OVER INLET AND SET TO 6" OF FINISH GRADE. PROPOSED D -BOX PROPOSED S.A.S. INSTALL WATERTIGHT RISER & PROVIDE TWO ACCESS MANHOLES TO WITHIN 3" OF FINISH GRADE FOR INSPECTION PURPOSES EXISTING\ T.O.F.=104.01 COVER SET TO 6" OF GRADE HOUSE(#44) F.G. EL.=103.21 F.G. EL.=103.2± F.G. EL.=102.0± F.G. EL.=102.0± /MAINTAIN 29 GRADE (MIN.) OVER S.A.S. T.O.F.=104.0± \\ L 12' L-5' 0 S=1% (MIN.) ' 4"SCH40 PVC ® S=1% (MIN.) 4"SCH40 PVC PA TIO � 6.. V'2 Jr3 �O9 48" LIQUIDLEVEL MosaimawME0VEXISTING ADD BAFFLE INV.=98.72 PROPOSED INV.=98.55TINV.=98.84± TGAS D -BOX ' 'N EXISTING SEPTIC TANK EXISTING INV.=98.50 2-500 GALLON LEACHING CHAMBERS SURROUNDED WITH STONE AS SHOWN S.A.S. H-10 RATED I�25'�I TOP CONC. ELEV.= 99.3 BREAKOUT ELEV.=99.00 + SEPTIC LAYOUT NOTES: INV. ELEV.=98.50 ®®®® ®1000 0000 10100® 1100®0 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS, PRIOR TO INSTALLATION. BOTTOM ELEV.=96.50 4' 2 X 8.5'=17.0' 4' 2) D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE 4' MIN. OF NATURALLY OCCURRING EFFECTIVE LENGTH = 25.0' ON A MECHANICALLY COMPACTED SIX INCH CRUSHED PERVIOUS MATERIAL ® ® ® ® 0 Ell E3 E3 E3 STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2). 5' MIN. ABOVE GROUNDWATER LEACHING SYSTEM SECTION 0 ®®®®® ®®® 33" ®LE@ 3) INSTALL INLET & OUTLET TEES AS REQUIRED. BOTT. OF TP, EL.=91.0 - ®®® E3 E3 Ell 4) CONTRACTOR SHALL INSTALL A GAS BAFFLE ON 3/4" TO 1-1/2" DOUBLE N > ® E3 EO E3 Ea 0 E3 0 E3 THE OUTLET TEE. WASHED STONE z 3" LAYER OF 1/8" TO 1/2" „ SEPTIC SYSTEM PROFILE DOUBLE WASHED STONE 102 (OR APPROVED FILTER FABRIC) 4" KNOCKOUT SOIL LOG DESIGN CRITERIA 20" DIA. COVER DATE: FEBRUARY 26, 2015 NUMBER OF BEDROOMS: 2 SOIL EVALUATOR: PETER McENTEE PE(SE#1542) 4" KNOCKOUT 4" KNOCKOUT 58" 0 SOIL TEXTURAL CLASS: CLASS I WITNESS: ANY VON HONE R.S. HEALTH AGENT DESIGN PERCOLATION RATE: <2 MIN/IN ELEV. TP DEPTH (0.74 GPD/SF LOADING RATE) 102.0 0" 4" KNOCKOUT DAILY FLOW: 220 GPD (design for 3) A SANDY .LOAM DESIGN FLOW: 330 GPD 10YR 4/2 GARBAGE GRINDER: NO 101.5 B 6" 500 GALLON CAPACITY, H-10 LOADING LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF SANDY LOAM CHAMBERS 1OYR 5/6 .74 GPD/SF 100.2 20" EXISTING SEPTIC TANK: 1000 GALLON CAPACITY O PERC N.T.S. PROPOSED DISTRIBUTION BOX: 1 INLET, 3 OUTLETS 1 34"/46" PROPOSED SEPTIC SYSTEM UPGRADE PLAN USE 2-500 GALLON LEACHING CHAMBERS IN SERIES MED. SAND 44 FISHING BROOK ROAD, WEST YARMOUTH, MA SURROUNDED BY DOUBLE WASHED STONE ON ALL SIDES 2.5Y 6/4 SIDEWALL AREA: 2(12.8' + 25.0') X 2 = 151.2 S.F. Prepared for: Capewide Enterprises, 153 Commercial St., Mashpee, MA 02649 BOTTOM AREA: 12.8' x 25.0' = 320.0 S.F. Engineering by: SCALE DRAWN JOB, N0. TOTAL AREA: .......................................................... I... 471.2 S.F. 91.0 132" Engineering Works, Inc. NTS P.T.M. 258-14 DATE 2/26/15 CHECKED P.T.M. SHEET NO. 2 DESIGN FLOW PROVIDED: 0.74 GPD/SF(471.2 SF) = 348.7 GPD NO GROUNDWATER, PERC RATE: <2 MIN./IN. 12 West Crossfield Road, Forestdale, MA 02644 (508) 477-5313 2 Of