Loading...
HomeMy WebLinkAboutEngineered Plan - 2014SYSTEM PROFILE „Yr (NOT TO SCALE) PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2" PEASTONE OR GEOTEXTILE 7, FILTER FABRIC OVER STONE 121.0' MINIMUM J5' OF COVER OVER PRECAST _ NOTE: 2- MIN. WALL PRECASTIH-10 THICKNESS REQUIRED RISERS (TYP.) I 4" OSCH40 PVC 2'm PIP/ES LEVEL 1ST 2' *19.0' 10" 14" (PROP.) 18.44 TEE TEE 1819 1 :: • i 17.62' .°°°°°°°°°°°° 1500 GAL H-10 GAS BAFFLE °�����°�00° 0.92' SEPTIC TANK18 �' 17.83' "'•'°0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o`c WATER TEST D'BOX FOR LEVELNESS • o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0;0;0, 0 0 0 0 0 °O°°o°°o°°°°°°°°°°p°°°p°°°p� n o 0 o r r_n_n_n.o 0 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [21) (_L.5% SLOPE) ( 1 % SLOPE) (_1_7. SLOPE) FOUNDATION- 16' SEPTIC TANK 19' D' BOX 23' *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM *(RE-ROUTE REQUIRED) VARIANCES REQUESTED: UNDER MAX. FEASIBLE COMPLIANCE 15.405: (1a): REDUCTION IN SETBACK, SAS TO LOT LINE (10' TO 6') (1b): REDUCTION IN SETBACK, SAS TO FOUNDATION (20' TO 18') UNDER TOWN OF YARMOUTH HEALTH REGULATIONS: (3.7): REDUCTION S SEPTIC TANKS TO BVWS(100'TO BTO 75') TO 66') TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: AMY VON HONE, RS DATE: 6/18/14 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. O„ 4 20.5' FILL 54" 16' B LS 65" 1OYR 5/6 15.1' PERC C M/CS 1OYR 7/8 150" 1 18' GROUNDWATER ENCOUNTERED 0 150" i4-352 l ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. t i PROVIDE INSPECTION PORTS TO WITHIN 3" OF FINISH GRADE 2% SLOPE REQUIRED OVER SYSTEM 18.0' 16.7' USE (11) HIGH CAPACITY H-20 INFILTRATOR UNITS (EACH UNIT = 6.25 x 2.83 x .,0.92' INVERT HEIGHT) (NO STONE PROPOSED) i 5 G -W ADJ. DATA: LEACHING WELL: MIW 29 FACILITY ZONE: B ADJ: 3.7' GROUNDWATER ADJUSTED ELEV. 11.7' 1 x 38 L, BENCH MARK - CTR OF CATCH o BASIN. ELEVATION = 19.7 I�®�\�c�`�, 5' REMOVAL OF UNSUITABLE SOIL REQUIRED \5$ r� AROUND PERIMETER OF LEACHING FACILITY, x 1 9 v � __x 20.49 DOWN TO SUITABLE SOIL LAYER. REPLACE SOLID BASIN \ X 20.40 WITH CLEAN MED. SAND, TO MEET x 19.98 �` \G� �x'�-O.18 SPECIFICATIONS OF 310 CMR 15.255(3) ®� � 9 X17/" 20 \ p i. ® � ,x. .x � -- 20.5 �®/ x(9.62 T .01 1 <0.29 1�� 00 �p - �r �.4 20.6 1 ? o ± 0.68 20.72 / / 118 x-20.92 20.92 \' / 2/ x 17.26 0.8 21.OB, / 8 1 .9 x 17 CA9 21. F4/T\�g \21.77 6p 21.39 19_1 ' ■ 21.46� / 21.85 1. 6 1 22. q G OCL .22�, rn 9I / 0 •�� ON• i�f•�r wiffil CA EXISTING LEACH TRENCH 2� We � 9 �1 1g Gov 18 1� 16 3 129 1�D a 11.17 x/14/21N / 11.28 Scale: 1"= 20' 0 10 20 30 40 50 FEET c do �. 2 i r lam. 1 V x 14.24 _ 14.73 *PLUMBING TO BE RE-ROUTED TO FRONT OF BUILDING. INSTALLER TC x15. CONFIRM FEASIBILITY PRIOR TO INSTALLING ANY PORTION OF SEPI 1 3 SYSTEM I co , I ,I 15.39 t N 1 � � 1N 1.0 1.07 4 Pio i 11.22 11 11.32 M 11 NOTES 1. DATUM IS ASSUMED 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8- PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND MAP VERIFYING THE LOCATION OF ALL UNDERGROUND & LOCUS MAP OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. NOT TO SCALE 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE ASSESSORS MAP 67 PARCEL 236 PROPOSED LEACHING FACILITY. NOTE: TWO BEDROOM DEED RESTRICTION REQUIRED 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. .Permit valid for REPAIR OF SEPTIC SN'S'FE:M ONLY, due to State and Local septic variances. Board of Ilealth review and approval is required for any future additions/renovations/alterations to sewage facilities and/or structures/dwelling. Yarmouth Health I)chartment APPROVE1) l Nerve - Date llav RENEWED FE8 2 0 2015 HEALTH DPT. DATE DANIEL A. OJALA, P.E., P.L.S. SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 2 BEDROOMS ® 110 GPD = 220 GPD USE A 220 GPD DESIGN FLOW SEPTIC TANK: 220 GPD (2) = 440 USE 1500 GAL. SEPTIC TANK LEACHING: 4.73 SF/LF x 6.25' LENGTH = 29.56 SF PER HIGH CAPACITY INFILTRATOR UNIT 220 GPD/0.74 GPD/SF .= 297.3 SF LEACHING REQ'D 297.3 SF/29.56 SF/UNIT = 10.1 UNITS THEREFORE, USE GRAVELLESS SYSTEM OF (11) H-20 HIGH CAPACITY UNITS IN FIELD CONFIGURATION AS SHOWN 11 UNITS x 29.5 SF = 324.5 SF > 297.3 SF 324.5 SF (0.74) = 240 GPD (OK) MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN! OF 67 SWIFT BROOK ROAD SOUTH YARMOUTH PREPARED FOR VERA O'HARA DECEMBER 23, 2014 off 508-362-4541 fax 508-362-9880 I downcope.com down cjjpe eineering, inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675