HomeMy WebLinkAboutEngineered Plan - Rev. 2015SEPTIC SYSTEM PROFILE COVERS TO r -FINISHED GRADE -----T-- 2-2 WAY _� I n I I PIPE TO BE LEVEL LEANOUTS II F -FOR 2' OUT OF D -BOX INSTALL OUTLET" TEE FILTER r97.73 96.43 96.6 H �20 D -BOX EXISTING 1000 GALLON 6" COMPACT STONE H-10 SEPTIC TANK OR COMPACTED B ASE F.G. 97.5 4 INSPECTION PORTS ON SAS TO GRADE 9 2 - TRENCHES 37.5' X 34' (12) INFILTRATORS HI CAPACITY H2O TEST HOLE LOG DATE: 1/21/15 1: OOPM TEST BY: MIKE O'LOUGHLIN WITNESS: AMY VON HONE PERC RATE: < 2 MIN PER IN -TOP @ 94.8 TEST HOLE # 1 TEST HOLE TEST HOLE # 3 p" 98.4 EL �" 98.1 EL n" 98.0 EL OTTOM @ 93.48 ) WATER ENCOUNTERED FILL 24" 96.4 EL AP LOAMY SAND 10Y 3/2 34" 95.58 EL LOAMY SAND 60" BW 10Y 5/6 93.4 EL FINE TO MEDIUM SAND 64" C 2.5Y 6/6 92.69 EL 72" FINE SAND 92.4 EL ) WATER ENCOUNTERED NO WATER ENCOUNTERED BOTTOM OF PERK 70" PRESOAK 10 MIN < 9" FILL 26" 95.94 EL A LOAMY SAND 10Y 3/2 32„ 95.44 EL LOAMY SAND 60" BW 10Y 5/6 93.1 EL FINE TO MEDIUM SAND 64" C 2.5Y 7/3 92.69 EL 120" FINE SAND 88.1 EL NO WATER ENCOUNTERED BOTTOM OF PERK 70" PRESOAK 10 MIN < 9" NO WATER ENCOUNTERED GENERAL NOTES 1. CONTRACTOR TO BE RESPONSIBLE FOR THE LOCATION OF ALL UTILITIES, ABOVE & UNDERGROUND, PRIOR TO ANY EXCAVATION OR CONSTRUCTION. 2. SEPTIC SYSTEM IS TO BE INSTALLED IN COMPLIANCE WITH 310 CMR 15.00: TITLE V. 3. THIS PLAN IS NOT TO BE USED FOR PROPERTY LINE DETERMINATION. 4. DESIGNER TO INSPECT & CERTIFY OVER -DIG, WHEN REQUIRED BY PLAN, AND FINAL INSPECTION BEFORE BACKFILL. 5. CONTRACTOR TO PROVIDE 48 HOUR NOTICE FOR ANY REQUIRED INSPECTIONS. 6. THIS SYSTEM IS NOT DESIGNED FOR THE USE OF A GARB AGE DISPOSAL. 7. THE TOP OF ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC MARKING TAPE OR A COMPARABLE MEANS IN ORDER TO LOCATE THEM ONCE BURIED. 8. IF SOILS ARE FOUND UNSUITABLE OR DIFFERING FROM THOSE FOUND IN SOIL LOG CONTACT DESIGNER AND THE BOARD OF HEALTH. 9. IF AN OVERDIG IS REQUIRED IN BELOW PLAN OR IF UNSUITABLE SOIL FOUND IN RESERVE AREA, CLEAN GRANULAR SAND MEETING 310CMR 15.255(3) SHOULD BE USED AS FILL MATERIAL, 5' AROUND AND UNDER S.A.S. 10. ALL 4" PIPE CONNECTIONS AT SEPTIC TANK AND D -BOX SHALL BE MORTARED IN PLACE. IF USING 18' PLASTIC RISER PIPES, THESE TOO SHALL BE MORTARED IN PLACE. DESIGN DATA DAILY FLOW: (3) BEDROOMS X 110 GPD = 330 GPD SEPTIC TANK: 330 GPD X 2 = 660 GPD USE: EXISTING 1000 GALLON H-10 MONO SEPTIC TANK DISTRIBUTION BOX: USE: DB -6 H-20 SOIL ABSORPTION SYSTEM: USE: (12) INFILTRATORS HI CAPACITY H-20 330/.74 = 445.95 445.95/7.79 = 57.21' LINEAR FT 57.21' / 6.25 = 9.15 UNITS REQUIRED 12.0 INFILTRATORS UNITS USED 12 UNITS X 6.25' = 75' X 7.79 X .74 = 432 GPD bkApPROVED Taa>�v Date HEALTH AGENT APPROVAL DATE FILL 8" 97.34 EL AP LOAMY SAND 10Y 3/2 16" 96.67 EL LOAMY SAND 40" BW 10Y 5/6 94.77 EL FINE TO MEDIUM SAND 64" C 1 2.5Y 6/6 92.69 EL FINE SAND C2 2.5Y 7/3 144" 86.0 EL NO WATER ENCOUNTERED GENERAL NOTES 1. CONTRACTOR TO BE RESPONSIBLE FOR THE LOCATION OF ALL UTILITIES, ABOVE & UNDERGROUND, PRIOR TO ANY EXCAVATION OR CONSTRUCTION. 2. SEPTIC SYSTEM IS TO BE INSTALLED IN COMPLIANCE WITH 310 CMR 15.00: TITLE V. 3. THIS PLAN IS NOT TO BE USED FOR PROPERTY LINE DETERMINATION. 4. DESIGNER TO INSPECT & CERTIFY OVER -DIG, WHEN REQUIRED BY PLAN, AND FINAL INSPECTION BEFORE BACKFILL. 5. CONTRACTOR TO PROVIDE 48 HOUR NOTICE FOR ANY REQUIRED INSPECTIONS. 6. THIS SYSTEM IS NOT DESIGNED FOR THE USE OF A GARB AGE DISPOSAL. 7. THE TOP OF ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC MARKING TAPE OR A COMPARABLE MEANS IN ORDER TO LOCATE THEM ONCE BURIED. 8. IF SOILS ARE FOUND UNSUITABLE OR DIFFERING FROM THOSE FOUND IN SOIL LOG CONTACT DESIGNER AND THE BOARD OF HEALTH. 9. IF AN OVERDIG IS REQUIRED IN BELOW PLAN OR IF UNSUITABLE SOIL FOUND IN RESERVE AREA, CLEAN GRANULAR SAND MEETING 310CMR 15.255(3) SHOULD BE USED AS FILL MATERIAL, 5' AROUND AND UNDER S.A.S. 10. ALL 4" PIPE CONNECTIONS AT SEPTIC TANK AND D -BOX SHALL BE MORTARED IN PLACE. IF USING 18' PLASTIC RISER PIPES, THESE TOO SHALL BE MORTARED IN PLACE. DESIGN DATA DAILY FLOW: (3) BEDROOMS X 110 GPD = 330 GPD SEPTIC TANK: 330 GPD X 2 = 660 GPD USE: EXISTING 1000 GALLON H-10 MONO SEPTIC TANK DISTRIBUTION BOX: USE: DB -6 H-20 SOIL ABSORPTION SYSTEM: USE: (12) INFILTRATORS HI CAPACITY H-20 330/.74 = 445.95 445.95/7.79 = 57.21' LINEAR FT 57.21' / 6.25 = 9.15 UNITS REQUIRED 12.0 INFILTRATORS UNITS USED 12 UNITS X 6.25' = 75' X 7.79 X .74 = 432 GPD bkApPROVED Taa>�v Date HEALTH AGENT APPROVAL DATE