Loading...
HomeMy WebLinkAboutEngineered Plan - 2014ACCESS COVERS MUST BE WITHIN _ 6. OF FINISH GRADE FIRST 2' TO F-1 BE LEVEL SECOND FLOOR PLAN 9- MINIMUM. 3' MAXI MUM. CO VER MIN 2" OF PEASTONE 3/4- - 1 1/2" DIA. v #/ , 98. 0 L i \ 96.63 /0- %. DOUBLE WASHED STONE cas -1 12.97.4 � '� 96.53 111 95.7 (EXI STI BAFFLE 96.8 ADD 2 CHAMBERS TO THE EXISTING 2-1000 GAL 3 OUTLET 5 HIGH CAPACITY INFILTRATOR SEPTIC TANKS D -BOX CHAMBERS W/3.5'+ STONE AROUND / (EXISTING) (EXISTING) 10'w X 50'1 X IO -d PROFILE : NOT TO SCALE + 100. 7 -1� o EXISTING ADD 2 CHAMBERS FOR A Q� D -BOX SHED TOTAL OF 7 HIGH CAPACI TY , 99 CL NOU INFILTRATOR CHAMBERS 9 0 W/3.5'f STONE AROUND yo' +lo0.a �TP* I •moi .. EXISTING cWi SAS _ + loo. z 77w#2 /00.40 +100-3 �C / EXISTING SEPTIC TANKS I / o / SM. CORNER BRICK to STEP. EL -100.73. � / \ FAM/ / BEDROOM R0041 Y KITCHEN BATH BE BATH UT/L / TY \ PANTRY / BEOROO,t/ /\ L I V/NG \ ROOM 3 1 < � A � / I v l i DESIGN CRITERIA DESIGN FLOW: 4 BEDROOMS AT 1/0 G.P.D. PER N BEDROOM EQUALS 440 G.P.D. NO GARBAGE GRINDER SEPTIC TANK REQUIRED: 440 G.P.D. X 2009 - 880 GAL. SEPTIC TANK PROVIDED: 2-1000 GAL EXISTING SOIL ABSORPTION SYSTEM REQUIRED: DESIGN PERC RATE C 5 MIN/ I NCH SOIL TEXTURAL CLASS - I EFFLUENT LOADING RATE - 0.74 GPD/SF 440 GPD / 0.74 GPD/SF 595 S.F. REQUIRED PROVIDED: 7 HIGH CAPACITY INFILTRATOR CHAMBERS W/3.5'± STONE AROUND. A-600 S.F. 600 S.F. x 0.74 - 444 GPD SOIL TEST PIT DA TA INDICATES 17 INDICATES PERCOLATION = OBSERVED TEST GROUNDWATER TP #I 0' HORIZON TEXTURE COLOR /00.3 A LOAMY IOYR SAND 4/2 8' -------------------- 99.6 B LOAMY IOYR SAND 5/8 26' -------------------- 98.1 C / MED -COARSE IOYR SAND 6/6 %D s \ I CA LOT A 40626 + S.F. 2 —A92 R0� {E O \A6 . t` Aa h0 b �I' 1• • D �, L EGEND 5 CP CONCRETE BOUND –A _W_ WATER L I NE HYDRANT 0P5� –A —G � GAS L INE OHW— OVER HEAD WIRES m t '`! LIGHT POST m --E— UNDERGROUND ELECTRIC LINE —T — UNDERGROUND TELEPHONE LINE — CTV-�- UNDERGROUND CABLEV I S I ON L 1 NE +40.41 SPOT ELEVATION EXISTING CONTOUR I 0 C 1 / C. MAP 0. l0 20 40 40 PROPOSED CONTOUR 42 - 120. NO WATER 90.3 DATE: AUGUST 9. 2001 TEST BY: STEPHEN HAAS WITNESSED BY: AMY VONHONE PERC RATE: C 2 MI N/I NCH GENERAL NO TES : 1. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYSTEM ONLY. 2. VERTICAL DATUM IS ASSUMED, FOR BENCH MARKS SET. SEE SITE PLAN. J. ALL CONSTRUCTION METHODS AND MATERIALS AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TI TLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 OR APPROVED EQUAL. 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE AND WATERTIGHT. D -BOX SHALL BE WATER TESTED TO CHECK FOR LEVEL WHEN THERE IS MORE THAN ONE OUTLET. 7. BEFORE CONSTRUCTION CALL -DIG-SAFE'. 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UTILITIES. �• - - �a..� N 3�1 rrd •� � r, SEPTIC S YS TQM LEES ION 2/ l B PLEASANT STREET MAP S1 PARCEL /0 SOUTH YARMOUTH . MA PREPARED 1= OR GARY SANDY SEE/ EY SCALE 1 — 20 OCTOBER 30 . 2014 STEPHEN A. HAAS ENGINEERING INC P.O. Box 16 South Denn i s MA 02660 ( 508) 362—B132 JOB. NO: 01-059. OF h1,ls�9`'r �k f of � ,J�A JOHN & Z. ,�iith tn a.l DEMAREST, JR ' V t'3 D No. 36859„ `1 W v �• - - �a..� N 3�1 rrd •� � r, SEPTIC S YS TQM LEES ION 2/ l B PLEASANT STREET MAP S1 PARCEL /0 SOUTH YARMOUTH . MA PREPARED 1= OR GARY SANDY SEE/ EY SCALE 1 — 20 OCTOBER 30 . 2014 STEPHEN A. HAAS ENGINEERING INC P.O. Box 16 South Denn i s MA 02660 ( 508) 362—B132 JOB. NO: 01-059.