' From: vonHone,Amy
Sent: Friday, December 19, 2014 9:30 AM
To: 'Daniel Gonsalves' �/� j
Subject: RE: 17 Hope Road �"�� � �� �
Attachments: 17 HOPE RD .PDF �
� �'
��,�/ /�,`,-�y°u� �/',Q
�'�" � � �
Hi Dan- � �� ����� �
`�" ��` � y !
I had a chance to review your plan and the surrounding properties.
You can use 1' off the adjustment (use adjustment of 1.5') and hold 4' above that, however, that will require a 2
bedroom deed restriction because of the groundwater variance. If you want to avoid the deed restriction, you
will need to hold 5' above. I won't require the deed restriction, however, the plan will still be stamped with a
condition that any future renovations or additions will require further BOH review. You will also need to list the
groundwater adjustment reduction as a variance under MFC. To avoid any potential restrictions on future
renovations, the leach will need to be 5' above the full adjustment.
A couple of other things to add to the plan:
1. Add the septic tank inlet tee length
2. Add the size of the pump chamber weep hole
3. Provide the Retaining Wall detail
4. Provide a 40 ml liner along the inside of the wall for breakout purposes and list the top and bottom
elevations of the liner
5. Provide the observed groundwater elevation (EL. 3.28 under the test hole log) for easier comparison
when looking at the related numbers/elevations on the plan
Call or email with questions.
Thanks, Amy
Amy L.von Hone, R.S., C.H.O.
' Assistant Health Director
Yarmouth Health Department
, _
From: Daniel Gonsalves [mailto:dgonsalvesColdowncape.com]
Sent: Friday, December 12, 2014 12:03 PM
To: vonHone, Amy
Subject: 17 Hope Road
Amy,
Attached is a rough plan of 17 Hope Road using the full groundwater adjustment. I have also attached two plans of
houses nearby that use%:the adjustment. I think that would be very helpful for this design and would keep the elevation
over the system consistent with others in the neighborhood. Please let me know what you think.
Thanks,
Danny E. Gonsalves, EIT
Engineer in Training
1
vonHone, Amy
From: vonHone, Amy
Sent: Monday, January 05, 2015 2:58 PM
To: 'Daniel Gonsalves'
Subject: RE: 17 Hope Road
Dan-
I just looked at the final full size draft plan for this property. One thing I didn't notice on the first draft was the
pump chamber cover is under the retaining wail. You will need to shift the tank to make sure the outlet cover is
accessible and to grade.
Everything else is ok.
Thanks, Amy
Amy L. von Hone, R.S., C.H.O.
Assistant Health Director
Yarmouth Health Department
From: Daniel Gonsalves [mailto:dgonsalvesCaldowncape.com]
Sent: Friday, December 12, 2014 12:03 PM
To: vonHone, Amy
Subject: 17 Hope Road
Amy,
Attached is a rough plan of 17 Hope Road using the full groundwater adjustment. I have also attached two plans of
houses nearby that use%:the adjustment. I think that would be very helpful for this design and would keep the elevation
over the system consistent with others in the neighborhood. Please let me know what you think.
Thanks,
. Danny E. Gonsalves, EIT
Engineer in Training
Down Cape Enaineerina. Inc.
Tel:508-3624541
' Faz:508-362-9880
This Electronic Message contains informadon
from the engineering firm of down cape engineering, inc.,
whith may be privileged. The information is intended
to be for the use of the addressee only. If you are not
the addressee, note that any disclosure,copy,distribution
or use of the contentr of this message is prohibited.
i