Loading...
HomeMy WebLinkAboutEngineered Plan - 2014SYSTEM PROFILE (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2" PEASTONE OR GEOTEXTILE UND. EL. 56.95' 1 ' FILTER FABRIC OVER STONE 5r 6.8� \ wall ILA 7r r%C• fleVICD !NICO DDCnec•r I I PRECAST H-10 RISERS (TYP.) 2'f 54.75'* 54.08' 0 I ALL SYSTEM COMPONENTS SHALL BEi MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADEI 2% SLOPE REQUIRED OVER SYSTEM57.0' BLOCKS OR I NOTE: MIN. WALL THICKNESS 2" PRECAST RISERS 4"OSCH40 PVC MORTAR ALL INVERT IN X3.3 - PIPES LEVEL 1ST 2' COMPONENTS ENDS (') j SIDES 54.13' 10" 1500 GAL H-10 14" TEE SEPTIC TANK TEE 3.83' �®�® DE2O® ®0�®- ��-'®® )o°°o 6" MIN. SUMP °°°°°°°° ®®®®®®®0®®� ®®D®®®®®@��® °% 81 °°°°°°°°°°°° a ;°°°°°°°° a®®®, ° ° GAS BAFFLE ::; °0°°°°0000°0 °°°°°°°° o o 0 0 °g °_opo°goo_ 12 MIN. INT. DIM. c� :°oao°000 ®®�0��®®®®0 ®®�0��®®�� 53.57' 53.4' 00000: J °goo°° 51.' 4' UQ. LEVEL (ACME OR EQUAL °"°'° ° :.....: .:.:. :: .........:..:�.: WATERTEST D'BOX I °0000o0°ooa0000000000000000000o000000o0 FOR LEVELNESS 0020 0 0 0 0000 0 0 0 0 0 0 0 0000 0 0 0 0. - " DOUBLE WASHED STONE 4' MIN. H-10 500 GAL. LEACHING CHAMBERS BY ACME PRECAST OR EQUAL „n -n,. n.n 0 0 0 0 0 0.0- _ _n_0.o 0 3/4"-1-1 /2 OU (2) UNITS REQUIRED ALL AROUND PRECAST STRUCTURES 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 25.00' X 12.83' COMPACTION. (15.221 [2]) ( 3.4 g; SLOPE) ( L% SLOPE) (-J-% SLOPE) LEACHING FOUNDATION- 20' SEPTIC TANK 1346.3' BOTTOM TH-1 D BOX 12 FACILITY NO GROUNDWATER FOUND i *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEND- EGEND99 99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. -[99]-- PROPOSED CONTOUR (98.4] PROPOSED SPOT EL. TH 1 00 TEST HOLE 2� SLOPE OF GROUND UTILITY POLE FIREHYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: -DANIEL E. GONSALVES, SE #13587 WITNESS. AMY VON HONE, RS DATE: 9/3/14 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. a" 4 56.8' A LS 4pp 1OYR 3/2 B LS 18" 1 OYR 5/6 55.3' PERC m MS 2.5Y 7/6 126" 146.3' NO GROUNDWATER ENCOUNTERED DCE #14-223 BENCHMARK I IRON PIPE EL. = 60.0' NOTES 1. DATUM IS ASSUMED 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -]Q 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND _ VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 113000, \ I I I I I II I LOT 78 8.7ss_ I ± , � SHED 0.2t Ac. \ (CPII I GI G I I G _- G -----IG , 1�t I � I co / I I DECK EXISTING IL( 1 1 II 1 II DWELLING OAK T.O. I I I 1 I I 16 . 1 // O / 10 EL. 56.95 CO / II \ I -a I II II II II II 119, I\i 128 I 90 j'II I I I I 0 \.n I Ill ' I 22.7 r I I III II TH1 J r I PAINED I DRIyE I J SLAB l \ p 14 10.2 � \qwN 6" HOLLY y z 100.E o I I Scale: 1"= 20' 0 10 20 30 40 50 FEET S1- 2.5 2014 HEALTH DEPT. �•3�I`1 DATE i ,. fiJu Yi � O�;t;i L'e�`c�2 CGe1C'.i'ai .7 �; I wm)e irate OF' A. 1= r DANIEL A. OJALA, P.E., P.L.S. I B h xit l oln t 00 a LIZ LOCUS Old Townhouse Rd. Iv n Stagy e � S1- 2.5 2014 HEALTH DEPT. �•3�I`1 DATE i ,. fiJu Yi � O�;t;i L'e�`c�2 CGe1C'.i'ai .7 �; I wm)e irate OF' A. 1= r DANIEL A. OJALA, P.E., P.L.S. LOCUS MAP NOT TO SCALE ASSESSORS MAP 86 PARCEL 150 SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED EXISTING 3 BEDROOM DWELLING DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL: 472 S.F. 349 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND , MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 39 WEBBERS PATH WEST YARMOUTH, MA PREPARED FOR LINDA VIA DATE: SEPTEMBER 3, 2014 off 508-362-4541 fax 508-362-9880 I downcope.com 00Wl1 cope enji17eerinv, int. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 14-223 VIA.DWG B h xit l oln t 00 a LOCUS Old Townhouse Rd. Iv n Stagy e � ordinal(S 0 o Q: B 3 � Cb Suffo/k 0 Oa m LOCUS MAP NOT TO SCALE ASSESSORS MAP 86 PARCEL 150 SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED EXISTING 3 BEDROOM DWELLING DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL: 472 S.F. 349 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND , MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 39 WEBBERS PATH WEST YARMOUTH, MA PREPARED FOR LINDA VIA DATE: SEPTEMBER 3, 2014 off 508-362-4541 fax 508-362-9880 I downcope.com 00Wl1 cope enji17eerinv, int. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 14-223 VIA.DWG