Loading...
HomeMy WebLinkAboutEngineered Plan - 2014--97— p 100 00 —EXISTING CONTOUR 9ti Z F`LSCR PK/SET TREETx100.98 EXISTING SPOT GRADE\S 98.93 97 PROPOSED CONTOUR / o .Vernent W EXISTING WATER SERVICE '' P / 99.62 J - 9 - — — 97,52 G EXISTING GAS SERVICE Locus S WINTER ST /1 Of ...:. •.. :; — — — — S -S2 $C-. e —$ H�W.— OVERHEAD WIRES °6 99.98 x 101,14 CB/SEAL TEST PIT x 101.18 .49 �y 102.08 -; 10017 101,51 i BENCHMARK \ ti YY eae s ' 5i 1.00,58 • i o s LEGEND Rour� o /�6Fj. -Q.,. .Q:''.. x 101,80 x 101,39 O \ o A• `� 100.45 �. �. ...: \ moi` -----K 101.99 10169 ,^ ` �,� X 101,23 �` \ LOCUS MAP rmit vji(�fiar REPAIR (>F SE TIC STEM _� NOT TO SCALE N1.Y, ego State and I.oca sep variances. Me th and -ova ` for = 1� and of review ap s required � X 101,0 My X 101,65 future additions/reuo atio .-/alterations to r 102,3 + X 10224 x 101,67 \ ; \ 0EAL•. ' wage facilities and/or stru IIIc dwelling. x 10 .02 10235 101,32+ • GENERAL NOTES: Varq)"#Pt ahl )epartmetft 103.08 .6 AC . ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL AP I ® �� �' 1BOARD OF HEALTH AND THE DESIGN ENGINEER. PORCH / EXISTING/ 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS m ` to OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE HOUSE (#60) C O LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW: ', f T.O.F.=10.3.2.% C0 .1 —310 CMR 15.405(1)(b): GARAGES o L 1 A 3' variance to the maximum cover requirement of 3', for me Date cn ) q // %� Q N up to 6 of cover. S.A.S, to be rated H-20 and vented. x 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR 102,16 ; is TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE 101,10 ,O �� 10244 o rrl DESIGN ENGINEER. 103.80 X n •x 101.2 4. DURING CONSTRUCTION DIFFERING X x ANY CONDITIONS ENCOUNTERED 103,31 DECK 0102,28 ; FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN iq 102, 7_ x 101.80 ENGINEER BEFORE CONSTRUCTION CONTINUES, STP1 x L = 4^ `* N 103,52 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. �:' +` '� 10 3.61 B d h x A \' BM / 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF 102,76 ^ry SOA 103.12 10 2,51 THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF !� `' '+' 0 102,99 + 101,26 X 101.1 CONSTRUCTION. x o HEALTH FOR PROPER INSPECTIONS DURING 103, Q SFS; �, 102,21 102,238 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S. 103. \ Qj 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS VENT �v/ + x 103,60 X 10 3.2 4 .k 103,15 ^j1 AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE BY THE AUTHORITIES. DIRECTED APPROVING S 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY X 103,8 THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING + 10368 ` CONSTRUCTION, �'�0 , EXISTING LEACH PIT 2y// �t� — 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS CONTRACTOR SHALL PUMP, /V �6a e \ IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND BENCHMARK REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). s9 X �0 of FILL WITH SAND & ABANDON QF M 3 + O OUTS/DE COR/BULKHEAD 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE ' 9 104.48 . SHED � V ELS=102.51 INSPECTED BY A LICENSED SOIL EVALUATOR PRIOR TO BACKFILL. T. �G� � LOT '1,OA � 0 0 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND o BE A PROPERTY LINE SURVEY, PETER IS NOT TO CONSIDERED McENTEE O 14. ENGINEERING WORKS, INC. IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED o� �' EXISTING SEPTIC TANK MBLU:132"142.1 SEPTIC SYSTEM COMPONENTS NOT SHOWN ON THE PLAN. CME No. 35109 TOP OF TANK, EL. =100.81 rrt RFc�Sj���°\ INV.(OU T)=99.48 19,568 tSF + 105.07 of `� +• PROPOSED SEPTIC SYSTEM UPGRADE PLAN S � ENG 10508 60 WINTER STREET, YARMOUTHPORT, MA �� Prepared for: Kara Sweet, 60 Winter Street, Yarmouthport, MA 02675 26-sd O 1 HOUSE LOCATION TAKEN FROM PLAN ENTITLED "PLAN OF HND, A/N/R PLAN N(3 QWNR OF RECORD Engineering by: SCALE DRAWN JOB. NO. „=20' P.T.M. AT #60 & #68 WINTER STREET, YARMOUTHPORT, MA DATED FEBRUARY 4, 2002 c� 62 SWEET, R KARA Engineering Works, Inc. 1 132-14 AND RECORDED IN PLAN BOOK 572 - PAGE 40 AT THE BARNSTABLE COUNTY 60 WINTER STREETDATE CHECKED SHEET NO. 12 West Crossfield Road, Forestdale, MA 02644 REGISTRY OF DEEDS. YARMOUTHPORT, MA (508) 477-5313 4/2/14 P.T.M. 1 Of 2 NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL:99.0 SEPTIC TANK FOR A DISTANCE OF 15' AROUND THE INSTALL RISERS & COVERS OVER INLET PERIMETER OF THE S.A.S. AND SET TO 6" OF FINISH GRADE.PROPOSED PROPOSED D -BOX S.A.S. PORCH PROVIDE ACCESS TO GRADE OVER OUTLET COVER PROVIDE TWO ACCESS MANHOLES TO WITHIN 3" EXISTING INSTALL WATERTIGHT RISER & OF FINISH GRADE FOR INSPECTION PURPOSES HOUSE 60 T.O.F.=103.2± COVER SET TO 6" OF GRADE CHARCOAL l# T.O.F.=103.2.E F.G. EL.=102.4± F.G. EL.=102.3± F.G. EL.=103.5± F.G. EL.=103.6± VENT MAINTAIN 2% GRADE (MIN.) OVER S.A.S. GARAGE O ®S=1%5(MIN.) 4"SCH40 ®S=1%5(MIN.) m CK PVC 4"SCH40 PVC �--' 10.1 141 EXISTING 48" LIQUID LEVEL♦ ADD INV,S PROPOSED INV.=98.55 44.840 44 �' / PROPOSED C♦ BAFFLE.=98.72 _ ... .... INV. -99.48± D -80X EFFECTIVE WIDTH =12.8- ♦ S.A.S. (VERIFY) H-20 RATED INV.=98.50 2-500 GALLON LEACHING CHAMBERS ♦♦♦♦ EXISTING SEPTIC TANK SURROUNDED WITH STONE AS SHOWN / ♦ H-20 RATED TOP BREAKOUT EELEV. g99. 0 I SEPTIC LAYOUT NOTES: INV. ELEV.=98.50 ®®a® 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE BOTTOM ELEV.=96.50 ®oil® ®®®®® INVERTS, PRIOR TO INSTALLATION. 8.5'=17.0' 4' 2) D -BOX SHALL BE SET LEVEL AND TRUE TO GRADE 4' MIN. OF NATURALLY OCCURING EFFECTIVE LENGTH 25.0' ON A MECHANICALLY COMPACTED SIX INCH CRUSHED PERVIOUS MATERIAL STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2). 5' MIN. ABOVE GROUNDWATER LEACHING SYSTEM SECTION ® ® ® ® 0El Ea E3 E3 Ea El 3) INSTALL INLET & OUTLET TEES AS REQUIRED. BOTT. OF TP, EL.=91.5 - I- ® ® ® ® ® ® ® ® ® ® ® 37" 4) CONTRACTOR SHALL INSPECT EFFLUENT FILTER ON 3/4" TO 1-1/2" DOUBLE I. W ®Ea Ea E3 Ea 0 231 E3 E3 E3 3z OUTLET TEE AND REPLACE IF NECESSARY. WASHED STONE 04z ® ®® IE3 E3 ®®® Ea 3" LAYER OF 1/8" TO 1/2" SEPTIC SYSTEM PROFILE DOUBLE WASHED STONE (OR APPROVED FILTER FABRIC) 102" SOIL LOG 4" KNOCKOUT DESIGN CRITERIA DATE: APRIL 2, 2014 20" DIA. COVER NUMBER OF BEDROOMS: 3 SOIL EVALUATOR: PETER McENTEE PE SOIL TEXTURAL CLASS: CLASS I WITNESS: AMY VON HONE R.S. HEALTH AGENT 4" KNOCKOUT 4" KNOCKOUT 58" DESIGN PERCOLATION RATE: <2 MIN/IN ELEV. TP DEPTH (0.74 GPD/SF LOADING RATE) 103.5 A LOAMY SAND DAILY FLOW: 330 GPD 103.0 10YR 4/2 6.. 4" KNOCKOUT DESIGN FLOW: 330 GPD B LOAMY SAND GARBAGE GRINDER: NO 10YR 5/8 101.5 24 500 GALLON CAPACITY, H-20 LOADING LEACHING AREA REQUIRED; (330 GPD) = 445.9 SF C1 LOAMY SAND. 2.5Y 7/3 GPD/SF 100 .8 32 CHAMBERS .74 EXISTING SEPTIC TANK: 1000 GALLON CAPACITY C2 SILT LOAM 5Y 5/3 N.T.S. PROPOSED DISTRIBUTION BOX: 1 INLET, 3 OUTLETS 98 7 C3 58" F D PERC PROPOSED SEPTIC SYSTEM UPGRADE PLAN USE 2-500 GALLON LEACHING CHAMBERS IN SERIES GRAVEL, COBBLES & 52"/64" BOULDERS IN C3 95.5 10YR 6/4 96 SURROUNDED BY DOUBLE WASHED STONE ON ALL SIDES 60 WINTER STREET, YARMOUTHPORT, MA SIDEWALL AREA: 2(12.8' + 25.0' X 2 = 151.2 S.F. ( ) Prepared for: Kara Sweet, 60 Winter Street, Yarmouthport, MA BOTTOM AREA: 12.8' x 25.0' = 320.0 S.F. c4 FINE SAND Engineering by: SCALE DRAWN JOB. N0. TOTAL AREA: .............................................................. 471.2 S.F. 2.5Y 7/3 Engineering Works, Inc. N.T.S. P.T.M. 132-14 DATE CHECKED SHEET NO. DESIGN FLOW PROVIDED: 0.74 GPD/SF(471.2 SF) = 348.7 GPD 91.5 144" 12 West Crossfield Road, Forestdale, MA 02644 PERC RATE <2 MIN/IN. ("C3" HORIZON) (508) 477-5313 4/2/14 P.T.M. 1 Of 2