HomeMy WebLinkAboutEngineered Plan - Rev. 1998TOP OF FRONT FOUNDATION 100.5 FINISH GRADE = 100.0 99.1 tank #1 FINISH GRADE = 100.5 tank #2 PROVIDE ACCESS TO PUMP AND FLOATS WITH MINIMUM 20" RISER. (EL.=101.0) MAINTAIN 2% MIN SLOPE OVER LEACHING AREA FINISH GRADE = 102.5 -� TOP OF S.A.S. RISERS/COVERS TO WITHIN 6' OF GRADE `,•-INV. ELEV. = 96.9 ELEV. = 101.23 (T# �) _ (T#2) C_2 22, L = VARIES (5' M LEACHING FIELD 4' PVC 4 PERFORATED; LEACHING FIELD SECTION NOT TO SCALE 2" LAYER OF 1/8"-1/2" WASHED STONE AX) PIPE PERFORATED PIPE ¢�� SCH ¢p 4" SCH 40 PVC h EXISTING ®S, o PVC, 14' I 6 SLOPE=0.005 FT/FT SEPTICMYv. O S= 0.01 FT/F7 TANK 1000 GAL. INV. ELEV. = 100.78 INV. ELEV. = 100.5 6" EFFECTIVE ,ALARM 0 SEE DETAIL 45, j DEPTH INV. ELEV. = 100.95 r 2• s 3• 2 . PUMP ON �� $» BOTTOM OF TRENCH I' BOTTOM 10,3/4"-1 1/2" PUMP OFF 1 2 INV. ELEV. = 96.65 MUST BE LEVEL ELEV. = 100.0 WASHED STONE INV. ELEV. = 100.73 TANK 1 EL.. 97.75 g" G.W. EL.: 96.0 (ADJUSTED) 1 TANK 2 EL.. 97.12 BOTTOM OF PUMPNcld f �� CHAM. ELEV. = 92.3 I SEPTIC SYSTEM PROFILE N.T.S. a �y. NOTE: SEPTIC TANK & PUMP CHAMBER ARE TO BE a SEALED & WRAPPED TO BE MADE WATERTIGHT. i - • I ., LOT 51 ^� 14,000 S.F. SEPTIC TANK N.T.S. DISTRIBUTION BOX (EXISTING SEPTIC TANKS TO . BE USED) N.T.S. 0 ooh 2" FORCED INLET FILL END KNOCK -OUTS 1/2' r � WITH MORTAR 15 1/2i tt 4 GRAVITY OUTLET / Oo 30 1/2• RAISE BULKHEAD FOUNDATION- TO / TGI-, k ELEVATION OF �` >,.� o°j �? _ _• HOUSE FOUNDATI 19 o SAs ' DRY WEL _ `•, /R,h'O SEE NOT _. ro12 PUMP CHAMBER_ _ - - - ERE UIREMENTS _ DOSING WIGGENPR , CAST CORP.; 'BOURNE .' MSA. DESIGN FLOW: ITEM #PC1000 P4SW (OR EQUAL) w HEAVY TOP (8) 33Q. ,GPD S / 1000 GALLON. -� .: ; - �.••� q „ PVC TO HOUSE. JOINTS TO BE i I DOSING REQUIRED: 4 CYCLES /DAY F �ARq NEMA 4 JUNCTION BOX CORROSION RESISTANT - 330 GPD o 4 = 82.5_ GAL/CYCLE q �,o tic C INSTALL 1-1 /4 O MADE WATERTIGHT. WIRE PUMP AND. FLOATS TO & LIQUID -TIGHT CABLE CONNECTORS' SUPPORTED DISTANCE'REQUIRED BETWEEN_ PUMP SIMPLEX - _ CONTROL PANEL No. 1 CC2 NEMA -1 MFG. BY 1-1/4 PVC CONDUIT. JOINTS TO BE MADE WATERTIGHT ON AND PUMP OFF FLOATS: To HOOVER INSTRUMENTS. - - 83 GAL/CYCLE o 250 GAL/FT = 0.33 FT CYCLE= ' ' HOISTING/ <<= co �G TF �p i q O - CABLE 7 x 19 STAINLESS STEEL 1/8 DIA. / 1,760 LB. STRENGTH 27BALL VALVE w UNIONS SCH.. 80 PV STORAGE AJB AS / C EREQUIRED--:ABOVE WORKING LEVEL. 330 O ti .. .. .. GEORGE FISHER CO. MODEL NO 560 STORAGE PROVIDED ABOVE WORKING LEVEL: --750 GAL.' 4 SCH. 40 - - _:. - •-- --__ :_.: _ .: -.._ _ _ �p'9Gy� - FROM TANK 2 SCH. 40 TO D -BOX . _ Cy � i T,s �Lq ALARM 0111 94.15 2 SCH. 40 TEL w/ CLEAN-OUT CAP, BUOYANCY CALCULATIONS ; . E _ -- J PUMP CHAMBER: PUMP ON 93.65 „ 1 _ _. .. 2. BALL CHECK VALVE SCH. 8 PVC HIGH GROUNDWATER. EL.=96.0 BOTTOM OF PUMP CHAMBER PUMP OFF 93.32 » 12» 8 100 P.S.I. FLOWMATIC MODEL No. 208S WATER DISPLACED = (96 - 92.3) x 4.8 x 8:3 = 147.4 C.F.✓�7i'G` $ WEIGHT OF DISPLACED WATER. = 147.4 C. F. x 62.4 Ib/cf 9,198 lbs. LEGEND • � WEIGHT OF H-10 1000 .GAL. PUMP CHAMBER w/ HEAVY TOP = 10,000 lbs. , " 2.'�/v 1/4" WEEP HOLE IN DISCHARGE PIPE 10,000 lbs. > 9,198 _lbs. (ACCEPTABLE) o o SEPTIC TANK �oarl.�/¢ /�.�Jpz � �'!�✓J�//z/('!-' (3) CONTROL FLOATS (BARNES 073612) 2SCH. 40 F'VC DISCHARGE PIPE GENERAL NOTES: BARNES SE41 1 PUMP .4 H.P. 115 u ❑ DISTRIBUTION BOX, ,n�i/�TT�,1��; ZvLr�T%/ •ris-iii 2" DISCHARGE PASSING 1-1 /2» SOLIDS - _ y rz 1 -56- - - EXISTING CONTOURS 1 • ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE YARMOUTH PROPOSED CONTOURS BOARD OF HEALTH AND ALPHA LAND SURVEYING & ENGINEERING. BM BENCH MARK a.' 2• ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF TrLE 5 OF THE STATE ENVIRONMENTAL CODE AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. - � TEST PIT (---------- PERFORATED PIPE 3. THE SEWAGE DISPOSAL SYSTEM SHALL .NOT BE BACKFILLED PRIOR � � - TO INSPECTION AND APPROVAL THE BOARD OF HEALTH AND/OR aaxs EXISTING SPOT GRADE ALPHA LAND SURVEYING & ENGINEERING. 20 0 20 40 60 Feet DESIGN I 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING CRITERIA 101 PROPOSED SPOT GRADE? D SCALE I"=20' FROM THOSE SHOWN HEREON SHALL BE REPORTED TO ALPHA' LAND SURVEYING & ENGINEERING BEFORE CONSTRUCTION CONTINUES. Al`_ 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. AI'I� 1 5 19��SOIL LOG 6. ALPHA LAND SURVEYING & ENGINEERING IS NOT RESPON SIB RESIDENCE NO. OF BEDROOMS:3 B.R. SINGLE DWELLING HEALTH DEPT. LE FOR THE �T'i'Pe Wl�1V U �•d-•11 -r N FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE BOARD OF SOIL TYPE: CLASS I TEST PIT TEST PIT DATA r HEALTH AND/OR ALPHA LAND SURVEYING & ENGINEERING FOR PROPER INSPECTIONS DURING CONSTRUCTION. DESIGN PERCOLATION RATE: 5.,MIN./IN. t1'( elev. 98:7' C 0"DATE: Mar. 21, 1998 REVISED 4/14/98: TO RESPOND TO B.O.H. COMMENTS. 7. TOWN WATER SUPPLY SERVICE IS PROVIDED. Loose LS DAILY FLOW: 330 G.P.D. (FILL) G.P.D.UBSURFACE SEWAGE DISPOSAL SOIL EVALUATOR: ALPHA LAND SURVEYING 8. THERE ARE NO PRIVATE WELLS LOCATED WITHIN 100' OF LEACHING AREA. � DESIGN FLOW: 330 ' 10 YR 6/2 & ENGINEERING (Peter .T. McEntee, PE , 1 9. SEPTIC SYSTEM COMPONENTS SHALL BE INSTALLED ON A LEVEL BASE ) Imo' 10. EXCAVATE TO ELEV. 95.7 (APPROX. 36") .OR LOWelev. 96.� ' 24" SYSTL E REPAIR/UPGRADE ER TO REMOVE ALL E Loose INSPECTOR: Rick Judd Yarmouth B.O.H. IMPERVIOUS MATERIAL BENEATH AND 5 FEET SURROUNDING LEACHING i' LS AREA AND REPLACE WITH CLEAN FILL MEETING THE SPECIFICATIONS GARBAGE GRINDER: No - 10 YR 3/3 » TEST PIT #1 I� �1, VUT��O�,� SACHUSETTS elev. 96,4 ar. 28 OF 310 CMR 15.255(3). LEACHING AREA REQUIRED. (330) - 445.9 S.F. B Loose' : Q 11. MODIFY EXISTING INTERIOR PLUMBING SO THAT PROPOSED SEPTIC TANK BOTTOM OF PIT: 90 inches74 LS GROUND WATER: OF jos. No. RECEIVES ALL SEWAGE FLOW. I ' 10 YR 5/6 43 inches - weeping from pit .face �Q��� Mgss ��� �F '��ss PREPARED FOR 12. PERIMETER DRAIN IS RECOMENDED ALONG HOUSE FOUNDATION IN AREA elev. 95.7' C 36°° G W '' o�� WILLI `�Q q�y BRUCE & KIM CLARKE 98121 SEPTIC TANK REQUIRED: 1,500 GAL. - o PETER T. SHEET No. OF PROPOSED GRADING TO INTERCEPT SURFACE RUNOFF. SEPTIC TANK PROVIDED: 2 - EXISTING 1,000 GAL. TANKS DEPTH OF PERC: 36 inches AC McENTEE Loose I 5037 CIVIL y 63 WEIR ROAD 1 of 1 13• IF EXISTING S.A.S. IS ENCOUNTERED DURING EXCAVATION IT SHALL BE Saturated PERC RATE. 4 MIN./IN. Sand A�OF �Q� No. 35109 YARMOUTHPORT, MASSACHUSETTS REMOVED AND REPLACED WITH SUITABLE MATERIAL DESCRIBED IN USE 10 x 45 LEACHING FIELD + ESS\o �Fc�SiE��° NOTE # 10. (Med. to l9yp DWG. NO. Fine) Note: MONITORING WELL INSTALLED AND DEPTH TO GROUNDWATER SUR`l'/Oftgl F DATE SCALE DRAWN FIELD CHECKED i 10 YR 4/4 OBSERVED AT 36' ON 3/23/98 ADJUSTED DEPTH TO 04/09/98 1" = 20' R.A.P. RAP/'m P.T.M. 98121-1 14. PURSUANT TO 310 CMR 15.404(2) MAXIMUM FEASABLE COMPLIANCE, SIDEWALL AREA: NONE GROUNDWATER = 2.7 EL.= 96.0 A 1 FOOT VARIANCE IS REQUESTED FORA 4 FOOT SEPERAELE BETWEEN `�A'I L7A aCKENZIE P.L.S. THE BOTTOM OF THE S.A.S. AND THE HIGH GROUNDWATER ELEVATION. REF: AIW-247 MARCH 1998 DATA (1/2 ADJUSTMENT). ho 'BOTTOM AREA: (10')(45) = 450 S.F. elev. 91.?' 90" 1182 MAIN STREET ® 15. ELECTRICAL PERMIT REQUIRED. WEST WAREHAM, MASSACHUSETTS 02576 ®�� � ®®®NG DESIGN FLOW PROVIDED: (0.74)(450 S.F.) LAN DSU RV EYING r = 333 G.P.D. (508) 295-5505 & ENGINEERING ASSOCIATES MATHEWS POND LOCUS ll � Rp -U/Ari ITE 6 LOCUS 1" = ±2600'