HomeMy WebLinkAboutEngineered Plans - 2015Permit 'valid for REPAIR OF SEPTIC SYSTEM
ONLY due to State_ and Isocal scptie variances.
Board of Health, review and approval is required for
any_ fut-ore Add itions/renovation ,talterations to
sewage facilities and/or structm-es/dwelling.
Yarmoutl Ilealth Department
AHVIO V 2.
ADDITIONAL NOTES:
1. THERE ARE NO ABUTTING FOUNDATION WALLS
WITHIN 20 FT. OF THE PROPOSED S.A.S.
2. THERE SHALL BE A 1 BEDROOM DEED RESTRICTION.
3. THE WATER SERVICE SHALL BE RELOCATED AND SLEEVED.
Date ROSETTA STREET
� 104,51 104,50
104 W 104,71 W 104,36
'9L PINE w o
j 6 5' U; 55 00'TO
�..`.
"rl R'OP' 104,87
N17
a
INSTALL A 40 MIL POLY LINER
AGAINST FOUNDATION
TOP OF LINER, EL.=103.0
BOTTOM OF LINER, EL.=100.0
LOT 291
LOT 290
EXISTING CESSPOOL
TO BE PUMPED, FILLED WITH
SAND AND ABANDONED
A
BENCHMARK
MAGNETIC NAIL SET
EL. =104.36
104,16
5:.30:•_ J ! = PROPOSED
,- 105.' 7 s SEPTIC TANK •
b Cj 105,11
105,31
EXISTING
HOUSE(J4) rio o LOT 285
T.O.F.=705.92.± o0 (CRAWL SPACE)l I
0 105,3
PORCH
105,13
LOT 2888
DECK IB U 28-77
400 fSF
CE 11
DL SHED
105,19 + 105,42
55.00'
LOT 287
VARIANCE REQUESTS
-310 CMR 15.405(1)(a)(b)&(g):
11)/ A 5' variance, S.A.S. to property line (side), for a 5' setback.
2) A 5' variance, S.A.S. to property line (front), for a 5' setback.
3) An 11.5' variance, S.A.S. to cellar wall, for a 9.5' setback.
4) A variance to allow a new sleeved water service to be installed
within 10' of the septic tank.
DECK
PORCH
1.
OFFICE
BATH KIT./DINING
LAUNDRY LIV. RM.
BEDROOM
j
FLOOR PAN
�P\.\\\ OF I'�AS 9�ti
S
o PETER T. G�
McENTEE
C> CIVIL
No. 35109
LOT 286
- 99 - -
EXISTING CONTOUR
,���
x 100.98
EXISTING SPOT GRADE
F9-7-1
PROPOSED CONTOUR
3. ADD "ADDITIONAL
i
-W-EXISTING
WATER SERVICE
-W-PROPOSED
WATER SERVICE
(TO BE SLEEVED)
-G-EXISTING
GAS SERVICE
$.H. W..--
OVERHEAD WIRES
®
TEST PIT
LeW15
{�
BENCHMARK
LEGEND
Bay
"....�..
o .yvva
,���
,
PLAN RVISION-4/16/15
1. SHOW WATER MAIN IN STREET.
-z�-•--`sHIOW--�A�•ER n� o I r\I-NN--S�R�-
3. ADD "ADDITIONAL
i
NOTES".
OWNER OF RECORD
VANBUSKIRK, NANCY L
C/0 ,WELLS FARGO REAL EST. TAX SVC
P.O. BOX 14506
DESMOINES, IA 50306
GENERAL NOTES:
N e
us Alboin t
4Rd
1'StiPork St
1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL
BOARD OF HEALTH AND THE DESIGN ENGINEER.
2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS
OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE
LOCAL RULES AND REGULATIONS EXCEPT AS NOTED UNDER VARIANCE
REQUESTS.
3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR
TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE
DESIGN ENGINEER.
4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING
FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN
ENGINEER BEFORE CONSTRUCTION CONTINUES.
5. ALL ELEVATIONS BASED ON ASSUMED DATUM.
6, THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF
THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF
HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION.
7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE.
8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S.
9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS
AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE
DIRECTED BY THE APPROVING AUTHORITIES,
10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING
CONSTRUCTION.
11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS
IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND
REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3).
12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE
INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL.
13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND
NOT CONSIDERED TO BE A PROPERTY LINE SURVEY.
14. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED SEPTIC
SYSTEM COMPONENTS NOT SHOWN ON THE PLAN
15. CONTRACTOR SHALL VERIFY THE ALL SEWAGE FLOW IS CONNECTED TO
THE PROPOSED SEPTIC SYSTEM.
PROPOSED SEPTIC SYSTEM UPGRADE PLAN
4 ROSETTA STREET, WEST YARMOUTH, MA
Prepared for: D. A. Brown, Inc., P.O. Box 145, Centerv44he, MA QPIE"752
Engineering by: Surveying by: SCALE DRAWN JOB. NO.
Engineering Works, Inc. JC Engineering, Inc. 1 "=20' P.T.M. 113-15
12 West Crossfield Road 2854 Cranberry Hwy. DATE CHECKED SHEET N0.
Forestdole, MA 02644 E.Wareham, MA 02538
(508) 477-5313 (508) 273-0377 4/15/15 P.T.M. 1 Of 2
NOTE: TO PREVENT BREAKOUT, FINAL GRADE
SEPTIC TANK
SHALL NOT BE AT, OR BELOW, E'=102.8
INSTALL RISERS & COVERS OVER INLET &
FOR A DISTANCE OF 15' FROM THE EDGE
OUTLET AND SET TO 6" OF FINISH GRADE PROPOSED D -BOX
OF THE PROPOSED S.A.S.
-CRAWL SPACE FLOOR INSTALL RISER & COVER
PROPOSED S.A.S.
SET TO 6" OF GRADE
INSTALL RISER & COVER: OVER EACH CHAMBER AND
�T
T.O.F=105.92±
SET TO 3" OF F.G. TO SERVE AS INSPECTION PORT
I oo iPROP. S.A.S1
F.G. EL.=105.31 F.G. EL.=105.4± F.G. EL.=105.0±
F.G. EL. -105.0±
N T ^ I
3 O
VZO
L = 10' , 3'(max.) 1 L 8'
_
® S=1% (MIN.) ® S=1% MIN. �_- 5'
IN
4"SCH40 PVC -•.• 4"SCH40(PVC) �4"SCH 0(P C)
2" LAYER OF 1/8" TO 1/2°
T6"1
DOUBLE WASHED STONE
iQ"I 6"
a®®�saa (OR APPROVED FILTER FABRIC)
EXISTING
I 14"
eB®®eea
HOUSE(#4)
INV.=102.75 48" LIQUID
sasses® --3/4" TO 1-1/2' DOUBLE
T.O.F.=905.92±
LEVELADD INV.= 102.42 PROPOSED
INV.=102.35
4' 4.8' 4' WASHED STONE
SPACE)
GAS BAFFLE D -BOX
EFFECTIVE WIDTH = 12.8'
/(CRAWL
INV.=102.50
3 OUTLETS INV.=102.30
PROPOSED SEPTIC TANK . H-20 1-500 GALLON LEACHING CHAMBER
PORCH
SURROUNDED
WITH STONE AS SHOWN
REDIRECT PLUMBING TO EXIT FRONT
OF HOUSE AT INV.=102.85
H-20 RATED
TOP CONC. ELEV.=103.4±
BREAKOUT ELEV. = 102. 80
SEPTIC LAYOUT
NOTES: NV. ELEV.=102.30
sees
®®Be®
1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE
aaaa®a®®eaa
INVERTS, PRIOR TO INSTALLATION. BOTTOM ELEV.=100.30
2) SEPTIC TANK & D -BOX SHALL BE SET LEVEL AND
TRUE TO GRADE ON A MECHANICALLY COMPACTED 4' OF NATURALLY OCCURRING
4' 8.5' 4'
EFFECTIVE LENGTH = 16.5'
SIX INCH CRUSHED STONE BASE, AS SPECIFIED PERVIOUS MATERIAL
IN 310 CMR 15.221(2). 5' (MIN.) ABOVE G.W.
LEACHING SYSTEM SECTION
E3 E3 Ea Ea E3 E3 E3 E3
3) INSTALL INLET & OUTLET TEES AS REQUIRED. NO G.W., EL.=95.3 z
® ® ® ®® ® ® ®® ® ® 37"
4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE
®
AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL.
N >
E3BE ®®®®®®
z
SEPTIC SYSTEM PROFILE
I
102"
SOIL LOG
4" KNOCKOUT
DESIGN CRITERIA
DATE: MARCH 18 2015
20" DIA. COVER
SOIL EVALUATOR: PETER 'MCENTEE PE(SE#1542)
NUMBER OF BEDROOMS: 1 BEDROOM
WITNESS: PHIL RENAUD HEALTH AGENT
SOIL TEXTURAL CLASS: CLASS I (EFFLUENT LOADING RATE=0.74 GPD/SF)
ELEV. TP DEPTH
4" KNOCKOUT 4" KNOCKOUT 58"
0
DESIGN PERCOLATION RATE: <2 MIN/IN
105.3 A 0"
DAILY FLOW: 110 GPD
LOAMY SAND
1OYR 4/2
4" KNOCKOUT
DESIGN FLOW: 220 GPD
103.8 18„
B
GARBAGE GRINDER: NO -not allowed with design
MED. SAND
LEACHING AREA REQUIRED: (220 GPD) = 297.3 SF
10YR 5/8 PERC500
GALLON CAPACITY, H-20 LOADING
.74 GPD/SF
21"/39"
CHAMBERS
PROPOSED SEPTIC TANK: 1500 GALLON CAPACITY
100.8 54"
PROPOSED D -BOX: 1 INLET, 3 OUTLET (MINIMUM), H-20 RATED
0
N.T.S.
PROPOSED SEPTIC SYSTEM UPGRADE PLAN
USE 1-500 GALLON LEACHING CHAMBER SURROUNDED
WITH 3/4 to 1-1/2 DOUBLE WASHED STONE -ALL SIDES
MED. SAND
2.5Y 7/3
4 ROSETTA STREET, WEST YARMOUTH, MA
SIDEWALL AREA: 2(12.8' + 16.5') x 2 = 117.2 SF
BOTIT(DU AREA,: 12.8' x 16.5' = 211.2 SF
I
Prepared for: D. A. Brown, Inc., P.O. Box 145, Centerville,. MA. 02632
Engineering by:
Surveying by:
SCALE
DRAWN
JOB. NO.
TOTAL AREA: 328.4 5F
95.3 120"
...............
'•'••"'••"""•"""'•""'••"•""""•"•
Engineering Works, Inc.
JC Engineering, Inc.
N.T.S.
P.T.M.
113-15
PERC
RATE: < 2 MIN./INCHB & C" HORIZONS)
12 West Crossfield Road
2854 Cranberry Hwy.
DESIGN FLOW PROVIDED: 0.74 GPD/SF(328.4 SF) = 243.0 GPD
Forestdale, MA 02644
E.Warehom, MA 02538
DATE
CHECKED
SHEET NO.
NO GROUNDWATER- ENCOUNTERED
(508) 477-5313
(508) 273-0377
4/1515
P.T.M.
2 Of 2