HomeMy WebLinkAboutEngineered Plan - 2010TOP OF FOUNDATION 20 FT. MINIMUM FROM CELLAR OR CRAWL SPACE ELEV. = 100.000 10 FT. MINIMUM 10 FT. MINIMUM FROM SLAB (ASSUMED) CONCRETE COVERS 4" 4" SCHEDULE 40 PVC PIPE �^ 7 MIN. PITCH 1/8" PER FT. 4 FEET 5 FEET 6 FEET 7 FEET 8 FEET u 4" CAST IRON PIPE (OR EQUAL) MINIMUM PITCH 1/4" PER FT. 5 1 LEGEND: EXISTING SPOT ELEVATION FLOW LINE EXISTING CONTOUR----00---- ELEV. = 96_Of - 10" -TMIN. i 00 ELEV. = 95.25 LEVEL ELEV. _ _95.42_ ADD GAELEV. _ 94_95 6" SUMP ELEV. = _94.78_ 30-120" BAFFLE _ DISTRIBUTION OUTLET TEE - - ELEV. _ BOX 14 INCHES (EXISTING) TO BE WATER TESTED 19 NCHES 24 (INCHES 1000 GALLON IF MORE THAN ONE OUTLET 329 INCHES 4 INCHES SEPTIC TANK (TO BE PLACED ON FIRM BASE) LJNER 3/4" TO 1 1/2" CLEAN -� 6. UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR DOUBLE WASHED STONE 11' X 36' X 10" TRENCH FORf�•ATION z FREE OF FINES & SILT 7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS SEWAGE DISPOSAL SYSTEM PROFILE SITE CONDITIONS PRIOR TO COMMENCINGWORK_ ON SITE. ANY VARIATION NOT TO SCALE A1W 247 ELEV. _ _ 924 _ 5 1 LEGEND: EXISTING SPOT ELEVATION 00x0 EXISTING CONTOUR----00---- FINAL SPOT ELEVATION 00.0 FINAL CONTOUR 00 SOIL TEST LOCATION 12-30" UTILITY POLE -0- LOAMY SAND TOWN WATER -W/-W 30-120" CATCH BASIN®) FINE SAND GAS LINE G - - CLEAN OUT C.O. ELEV. CESSPOOL C.P.0 v x 92.8 `'/ \ . / 40 ML VINYL LINE Di B?X I t o� x 94.8 s CLEAN SAND INSPECTION PORT,, LOAM ANh SEED 2" DYER OF 1/8" TO 1/2" WASID STONE 98.28 MAX. OR FINER FABRIC VENT 96.03 MIN. NOT REQUIRED f � 0 0 0i 95.28 a' TEXTURE COLOR MOTT. OTHER 0_-12" ELEV., _ _ 95.4 LOAMY SAND 10YR4/4 NO ROOTS 12-30" B LOAMY SAND 10YR4/6 ROOTS 30-120" C FINE SAND 10YR6/4 - - S_5MIN./IN. ELEV. - _93.95_ 40 ML 474_33 SQ. FT. (11X36)+(47X2X10/12) VINYL 4 HIGH CAPACITY 474.33 X 0.74 LJNER INFILTRATORS WITH STONE IN AN 6. UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR IS TO CALL "DIG -SAFE" AT 1-888-344-7233 AT LEAST 72 HOURS 11' X 36' X 10" TRENCH FORf�•ATION z 'g5 7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS SOIL ABSORPTION! SITE CONDITIONS PRIOR TO COMMENCINGWORK_ ON SITE. ANY VARIATION WELL A1W 247 ELEV. _ _ 924 _ IMMEDIATELY. ZONE C SYSTEM (SAS) INDEX 20.6 (5/2010) I ADJUST 0 RECORD HIGH REPLACED WITH MATERIAL AS SPECIFIED IN 310 CMR 15.255:(3). USGS PROBABLE WATER TA:3LE ELEV. = OBSERVED WATER TABLE (6/24/2610) ELEV. = _1$Q__ BOTTOM OF TEST HALE ELEV. = . x 97.5 L. (W j o L f APPROVED o • 95. / ! SOIL x 97.4 1 / TEST x 9 .5 x 97.4 93� LOT 5 / 8.8 18,851 f S. F. I /'r 00 99.2 / 9 .1 9.4 I /DECK 9.4 DR/� 99.0 98.0 x 8.8 / 1/ L / 0 =� �� f3 x 7.3 Y / \ 97.7 / 1 l m�o� o x 98.9 97 '1000 GALLON f /SEPTIC TAN( 98.0 4 o I � 8.3 � 98.8 x 99. x 98.6 ' 97.7 � � I •Y 0 97.E �. x I i 99.1 SOIL TEST BATE OF SOIL TEST 4UNE_241_2010 SOIL .TEST DONE BY SWEETSER ENGINEERING WITNESSED BY A VON HONE ---- OBSERVATION HOLE 1 ELEV.=_ 96.0_ PERCOLATION RATE <_2MIN./INCH AT 694- INCHES m z D DEPTH HORIZ TEXTURE COLOR MOTT. OTHER 0_-12" Ap _ LOAMY SAND 10YR4/4 NO ROOTS 12-30" B LOAMY SAND 10YR4/6 ROOTS 30-120" C FINE SAND 10YR6/4 WATER ENCOUNTERED AT __96__ ELEV. = _ 88.0 _ DESIGN CALCULATIONS NUMBER OF BEDROOMS 2 DESIGN FOR 3 (NOT IN A ZONE 11) GARBAGE DISPOSAL UNIT ^IW_ _ TOTAL ESTIMATED FLOW 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO ( 110 GAL/BR./DAY X 3 BR.) _33Q_ GAL./DAY REQUIRED SEPTIC TANK CAPACITY -§Q_ GAL. ACTUAL SIZE OF SEPTIC TANK (EXISTING) 1000 GAL. SOIL CLASSIFICATION DESIGN PERCOLATION RATE S_5MIN./IN. EFFLUENT LOADING RATE 4,74 GAL./DAY/S.F. LEACHING AREA 474_33 SQ. FT. (11X36)+(47X2X10/12) LEACHING CAPACITY (AREA X RATE) _MbDQ GAL./DAY 474.33 X 0.74 RESERVE LEACHING CAPACITY -liQN&L GAL./DAY NOTES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE 5 AND THE TOWN'S RULES AND REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE. 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO WITHIN 6" OF FINISHED GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF SFr RR ENGDVEERUX 203 SETUCKET ROAD 508- P. 0. BOX 713 385-6900 SOUTH DENNIS, MASS. 02660 WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. 4. ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL BE MORTARED IN PLACE. 5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY., 6. UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR IS TO CALL "DIG -SAFE" AT 1-888-344-7233 AT LEAST 72 HOURS LOCATION MAP PRIOR TO COMMENCING WORK ON SITE. FSHEET 1 OF 1 7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS SITE CONDITIONS PRIOR TO COMMENCINGWORK_ ON SITE. ANY VARIATION �(} !S TO L.. i3fi +l.lJT..TO ,-iriE ATT'.ENT1 ON OF HE DESIGN ENIC;4 NESE l IMMEDIATELY. 8. PARCEL IS IN FLOOD ZONE C____. 9. LOT IS SHOWN ON ASSESSORS MAP __!Q_6__ AS PARCEL 81 _ 10. ALL UNSUITABLE MATERIAL SHALL BE REMOVED FROM UNDER AND FOR A MINIMUM OF 5' AROUND SOIL ABSORPTION SYSTEM AND BE REPLACED WITH MATERIAL AS SPECIFIED IN 310 CMR 15.255:(3). 11. EXISTING LEACHING FACILITIES ARE TO BE PUMPED AND BACKFILLED OR REMOVED. .m� I . ;d®�fh health Department (W j o L APPROVED o j n W LLU APPROVED: BOARD OF HEALTH DATE AGENT YARHO rrr HA SS. LOCUS � B��K AR EX/ST 8 J� -®- �o�� 6 PROPOSED SEPTIC DESIGN FOR STACY COI 'DES LOC. 14- DE VERU LAT+dE, LOT 5 YARMOUTH, MASS. SFr RR ENGDVEERUX 203 SETUCKET ROAD 508- P. 0. BOX 713 385-6900 SOUTH DENNIS, MASS. 02660 DATE JUNE 24, 2 ICALE 1" = 20' Eno- 6957-00 REV. LOCATION MAP REV. FSHEET 1 OF 1