HomeMy WebLinkAboutEngineered Plan - 2015BE C 'a 20 FT. M':N,muto FROM CELLAR OR ' ' Ni SPACE TCP OF FOUNDATION 10 FT, MINIMUM FROM SLAB ELE`✓ = 1p0,� -� j 10 FT. MINIMUM (ASSUMILD) I CONCRETE I COVERS 6. 4" CAST IRON PIPE -{ - 99.2 CONCRETE COVERS i 4" SCHEDULE 40 PVC PIPE � MIN. PITCH 1/8" PER FT. -\ X i �6 m Ax. -I CLEAN SAND �--INSPECTION PORT --LOAM AND SEED \ \ \ 2" LAYER OF 1 /8" TO 1 /2" \ \ AASHED STONE \ � '`R FILTER FABRIC ! 98.33 MAX. \ 96.08 (AIN. VENT NOT REQUIRED DD GAS I E E F E (EX,STING) 1000 GALLON SEPTIC TANK (OR EQUAL) MINIMUM j PITCH 1/4" PER FT.I 98.16 N DISTRIBUTION _E'v �; g_�RSh:T- 6.30 I BOX - sToN �AN TO BE WATER TESTED ' i 11' X 48 X 10 RE's ' -;` ti ` -"N---� IF MORE THAN ONE OUTLET -- c (To BE PLACED ON FIRM BASE) SOIL STEt�O(SAS)N 3,/4" TO 1 1/2, CLEAN 1-4 FEE _ \ \ 9 DOU3L- r.�S~E� STONE FREE OF FINES, & SILT C,t_, 7 rEET L9 'NCN-S F LOW ;4 - I ! I ---_ C --ELN OV, - �LSSpGrlL LEVELERS;TEE ! YR6/1 �� 178-126" IC3 MEDIUM SAND L1OYR7/4 FLc7W LINE _ (- FLOW ! 95.33 • �� a D - . . = 97.51 `� 0.. 1 MIN. LINE —_� 10„ ,.. __ - -ELEw. - _96.74_ I MIN. 96_53 1 0 _ �� - 'Ed ° I ° 10. _ 94.00 --- - LLE . - - LE /h' ------ E'LE` - _ 96.91 - J — 96 70 - 95.00 SUMP ` E . _ _94_83_ r. o _ DD GAS I E E F E (EX,STING) 1000 GALLON SEPTIC TANK (TO BE PLACED ON FIRM BASE) 1000 GALLON SEPTIC TANK N DISTRIBUTION _E'v �; g_�RSh:T- 6.30 I BOX - sToN �AN TO BE WATER TESTED ' i 11' X 48 X 10 RE's ' -;` ti ` -"N---� IF MORE THAN ONE OUTLET -- c (To BE PLACED ON FIRM BASE) SOIL STEt�O(SAS)N 3,/4" TO 1 1/2, CLEAN 1-4 FEE _ 4 ' .C,ES 5 •EET 9 DOU3L- r.�S~E� STONE FREE OF FINES, & SILT C,t_, 7 rEET L9 'NCN-S 8 F , ;4 - DD GAS I E E F E (EX,STING) 1000 GALLON SEPTIC TANK (TO BE PLACED ON FIRM BASE) 1000 GALLON SEPTIC TANK N DISTRIBUTION _E'v �; g_�RSh:T- 6.30 I BOX - sToN �AN TO BE WATER TESTED ' i 11' X 48 X 10 RE's ' -;` ti ` -"N---� IF MORE THAN ONE OUTLET -- c (To BE PLACED ON FIRM BASE) SOIL STEt�O(SAS)N 3,/4" TO 1 1/2, CLEAN d�ELL N A �— ZONE !NDEX ADJUST SEWAGE DISPOSAL SYSTEM PROFILE 7-13" A/E DOU3L- r.�S~E� STONE FREE OF FINES, & SILT PROBLB'-E AATEK TABLE ELE'.. _ ------ OBSER'V'ED wA.TER TABLE NOT TO SCALE j13-30 IB �C1 LOAMY SAND B SIN I GMS -IN- ---_ C 2 LEGEND: TEXTURE (COLOR EXSi NG r �LtvA` -N UG„U FILL NO 7-13" A/E SOIL TEST-OCAT,ON 10YR7/1 ROOTS j13-30 IB �C1 LOAMY SAND B SIN + ROOTS GMS -IN- ---_ C --ELN OV, - �LSSpGrlL ? J • 83.p4p 0 SOIL TEST DATE OF SOIL TEST eRIL 232015 SOIL TEST DONE BY agETaER ENGINEERING WITNESSED BY-A•_YQ.N IiJ NL_ ------ OBSERVATION HOLE 1 ELEV.=__98.2 _ PFRrnI ATION RATE < _5-- M!N./INCH AT __44___ INCHES I DEPTH HORIZ TEXTURE (COLOR MOTT. OTHER 0-7'” FILL NO 7-13" A/E LOAMY SAND 10YR7/1 ROOTS j13-30 IB �C1 LOAMY SAND 10YR7/4 + ROOTS 130-50" 'MEDIUM SAND 10YR7/4 I {150-78" iC2 SANDY LOAM YR6/1 I 178-126" IC3 MEDIUM SAND L1OYR7/4 NO WATER ENCOUNTERED AT fib _ ELEV. DESIGN CALCULATIONS 4 NUMBER OF BEDROOMS - GARBAGE DISPOSAL UNIT ----- TOTAL ESTIMATED FLOW ( 110 GAL/BR./DAY X ___4 BR.) __4A4_ GAL./DAY REQUIRED FIRST SEPTIC TANK CAPACITY __MQ - GAL. ACTUAL SIZE OF FIRST SEPTIC TANK (E)aSTING)_1000 GAL. REQUIRED SECOND SEPTIC TANK CAPACITY --4(1- GAL. ACTUAL SIZE OF SECOND SEPTIC TANK 1000 GAL. SOIL CLASSIFICATION ---- DESIGN PERCOLATION RATE S_5__ MIN./ N. EFFLJENT LOADING RATE GAL./DAY/S.F. EACHING AREA. 626 33 SQ. FT. (11x48)+(59x2X10/12) LEACHING CAPACITY (AREA X RATE; .0 GAL./DAY 626.33 X 0.74 RESERVE LEACHING CAPACITY AOff- GAL./DAY NOTES: 1, ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO. D.E.P. TITLE 5 AND THE TOWN'S RULES AND REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE. 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO WITHIN 6" OF .FINISHED GRADE. 3. ALL. COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 10 FT. OF DR:VES OR PARKING AREAS. H-20 LOADING SHALL BE USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. 4. ANY MASONARY UNITS USED TO 3RING COVERS TO GRADE SHALL BE MORTARED IN PL,.CE. 5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 6. UTILITIES SrOWN ARE APPROXIMATE ONLY, IEXCAVATION CONTRACTOR IS TO CALL "DIG --SAFE" AT 1-888-344-7233 AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE. 7. CONTRACTOR IS TO VERIFY GRADES .AND ELEVATIONS AS WELL AS SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION IS TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER vMEDIATEL'Y. 8 PARCEL IS N FLOOD ZONE ---C-- 21-- 9. 'LOT S SHOWN ON ASSESSORS MAP --1-0-8-- AS PARCEL ____ 10. ALL UNSU!TAaLE MATERIAL SHALL BE REMOVED FROM _:NDER AND FOR A MINIMUM OF 5' AROUND SOr_ ABSORPTION SYSTEM AND BE REPLACED WITH MATERIAL AS SPECIFIED IN 310 CMR 115.255:07111 ) EXISTING LEACH PITS ARE TO BE PUMPED AND REM OVEG-I9R-iB' +,�4_,LLED D r F ame Dat. APPROVED: BOARD OF HEALTH DATE AGENT PROPOSED SEPTIC DESIGN YARMOUTH, MASS. F(D,:, 'I REALTY TRUST LOCUS DAVERPORT ZL 57/59 JOEL ROAD, LOT 11 YARMOUTH, MASS. i o ` SEER EJVGINEERNG 203 SETUCKET ROAD _ P. 0. BOX 713 j 506 SOUTH DENNIS, MASS. 02660 385-6900 6 DATE APR. <3, 201 � SCALE 1 „ = 20' REV. I JOB No. 7557--00 j RE\� II SHEET 1 OF 1 ' L_O�,ATION MAP C.• \S81PR0✓'17557-00\Cwg\7557-SASDwG C2015 SWEETSER ENG!NEERIt