FLOOR PLAN
9.8
40 ml POLY LINER
PROP. 1,500G
SEPTIC TANK
'.WATER SERVICE SLEEVED
PIPE ENTIRE IENG
40 ml POLY LINER
cRAwL
19.
/TBM = EL. 20.4
CONCRETE 5TEP
FULL
�0
Permit; valid for REPAIR 0 Sr.r 11C SYS "I'EM
ON, LY, due to State anti local septic variances.
Board of tl'ealth review anti approval is required for
any future additions/ren ova (ionsiaIterations to
sewage facilities and/or structures/dwelling.
Yarmouth Health I)c.partment
APPROVED
20
O.1 O ACRE5
GRAPHIC SCALE
10 20 40
( IN FEET )
1 inch = 20 ft.
VARIANCE REQUESTS - MAXIMUM FEASIBLE COMPLIANCE
PER 310CMR15.405 (1)(b):
1) A 11.5 FT. VARIANCE FROM 310 CMR 15.211 TO ALLOW LEACHING TO BE 8.5 FT. FROM CRAWL SPACE VS. REQ'D 20 FT. (LINER PROV.)
2) A 3 FT. VARIANCE FROM 310 CMR 15.211 TO ALLOW SEPTIC TANK TO BE 7.0 FT. FROM CRAWL SPACE VS. REQ'D 10 FT.
PER 310CMR15.405 (1)(a):
1) A 3 FT. VARIANCE FROM 310 CMR 15.211 TO ALLOW LEACHING TO BE 7.0 FT. FROM WATER LINE VS. REQ'D 10 FT. (SLEEVE/LINER PROV.)
YARMOUTH
LOCUS MAP
LOCUS INFORMATION
TITLE REF: 17861/070
PARCEL ID: MAP 22 PAR. 390
SEPTIC SYSTEM
REPAIR PLAN
LOCATED AT:
32 MASSACHUSETTS AVE.
WEST YARMOUTH, MA
PREPARED FOR
BONNIE RICCI
MAY 7, 2015
2�����ti OF Mgssq��G
o ,�RRFNr,M.
MEYER & SONS, INC.
P.O. BOX 981
EAST SANDWICH, MA. 02537
PH: (508)360-3311
FAX: (774)413-9468
meyerandsonstitle5@gmail.com
www.meyerandsons.com
SHEET 1 OF 2 J#1744
LEGEND
PROPOSED CONTOUR
F9-8-1
PROPOSED SPOT GRADE
--98--
EXISTING CONTOUR
+ 96.52
EXISTING SPOT GRADE
W—
EXISTING WATER SERVICE
TEST PIT
FLOOR PLAN
9.8
40 ml POLY LINER
PROP. 1,500G
SEPTIC TANK
'.WATER SERVICE SLEEVED
PIPE ENTIRE IENG
40 ml POLY LINER
cRAwL
19.
/TBM = EL. 20.4
CONCRETE 5TEP
FULL
�0
Permit; valid for REPAIR 0 Sr.r 11C SYS "I'EM
ON, LY, due to State anti local septic variances.
Board of tl'ealth review anti approval is required for
any future additions/ren ova (ionsiaIterations to
sewage facilities and/or structures/dwelling.
Yarmouth Health I)c.partment
APPROVED
20
O.1 O ACRE5
GRAPHIC SCALE
10 20 40
( IN FEET )
1 inch = 20 ft.
VARIANCE REQUESTS - MAXIMUM FEASIBLE COMPLIANCE
PER 310CMR15.405 (1)(b):
1) A 11.5 FT. VARIANCE FROM 310 CMR 15.211 TO ALLOW LEACHING TO BE 8.5 FT. FROM CRAWL SPACE VS. REQ'D 20 FT. (LINER PROV.)
2) A 3 FT. VARIANCE FROM 310 CMR 15.211 TO ALLOW SEPTIC TANK TO BE 7.0 FT. FROM CRAWL SPACE VS. REQ'D 10 FT.
PER 310CMR15.405 (1)(a):
1) A 3 FT. VARIANCE FROM 310 CMR 15.211 TO ALLOW LEACHING TO BE 7.0 FT. FROM WATER LINE VS. REQ'D 10 FT. (SLEEVE/LINER PROV.)
YARMOUTH
LOCUS MAP
LOCUS INFORMATION
TITLE REF: 17861/070
PARCEL ID: MAP 22 PAR. 390
SEPTIC SYSTEM
REPAIR PLAN
LOCATED AT:
32 MASSACHUSETTS AVE.
WEST YARMOUTH, MA
PREPARED FOR
BONNIE RICCI
MAY 7, 2015
2�����ti OF Mgssq��G
o ,�RRFNr,M.
MEYER & SONS, INC.
P.O. BOX 981
EAST SANDWICH, MA. 02537
PH: (508)360-3311
FAX: (774)413-9468
meyerandsonstitle5@gmail.com
www.meyerandsons.com
SHEET 1 OF 2 J#1744
P
NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS
T.O.F. EL.=20.0f SEPTIC TANK PROPOSED D -BOX
INSTALL RISERS & COVERS OVER INLET & INSTALL RISER & COVER
OUTLET AND SET TO 6" OF FINISH GRADE SET TO 6" OF GRADE
F.G. EL.=19.51 F.G. EL.=19.5f
/- � F.G. EL: 19.5f
9" MIN COVER/
36" MAX COVER L = 10'
a S=1% (MIN.) EL. = 134.86 : 0 S=1% (MIN.)
4"SCH40 PVC 4"SCH40 PVC
U_L10"I
INV.=17.25 14'
48" LIQUID INV.= 17.00
LEVEL
I GAS BAFFLE
�..................• •,:..•,.......... I INV.=16.87
PROP. 1.500 GALLON (H2O) SEPTIC TANK
EXIST. SEWER OUTLET
INV. =18.0
NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING
PIPE INVERTS PRIOR TO CONSTRUCTION
2) TANK AND D -BOX SHALL BE SET LEVEL AND
TRUE TO GRADE ON A MECHANICALLY COMPACTED
SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN
310 CMR 15.221(2)
3) INSTALL INLET & OUTLET TEES W/
GAS BAFFLE AS REQUIRED
DESIGN CRITERIA
L= 1O'(MAX)
® S=1% (MIN.)
4'SCH40 PVC
11.3" TO
INVERT
INV.=16.6 -
PROPOSED
D -BOX INV.=16.70
DB -5
H2O
BREAKOUT=TOP ELEV.=16.99
INV. ELEV.= 16.60
BOTTOM ELEV.= 15.66
NOTE: TO PREVENT BREAKOUT, THE PROPOSED
FINISH GRADE SHALL NOT BE < EL:17.0
FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S.
PROPOSED S.A.S.
INSTALL A 4" DIAMETER INSPECTION PORT OVER
ONE CHAMBER (MIN.) AND SET TO 3" OF F.G.
//-F.G. EL: 19.50(MAX.)
5' MIN. ABOVE BOTTOM OF
T.P. EXCAVATION OR G.W.
(7.83' PROVIDED)
BOTTOM OF TESTHOLE: EL: 7.83
SEPTIC SYSTEM PROFILE
NUMBER OF BEDROOMS: 3 BEDROOM DESIGN
DESIGN FLOW: RESIDENTIAL: 3 BEDROOMS 0 110 GPD/BR = 330 GPD
DESIGN PERCOLATION RATE: <2 MIN/IN SOIL TEXTURAL CLASS: CLASS I
GARBAGE GRINDER: NO (not designed for garbage grinder)
DISTRIBUTION BOX: USE DB -5 (H20)
N.T.S.
(0.74 GPD/SF)
SEPTIC TANK: 330 gpd x 200% = 660 gpd USE PROP. 1,50OG SEPTIC TANK
LEACHING AREA REQUIRED: (330)/.74 = 445.94 S.F.
PRIMARY S.A.S.
USE 4 ROWS OF 4 - HI -CAP INFILTRATOR H-20 UNITS -NO STONE
BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF OF CHAMBER)
(CHAMBER) 16 UNITS x 6.25 LF x 4.73 SF/LF = 473.0 SF
TOTAL AREA = 473 SF
DESIGN FLOW PROVIDED: 0.74GPD/SF(473SF) = 350 GPD > 330 GPD req'd
INSTALL TWO INSPECTION PORTS (MIN.)
4 ROWS OF 4 UNITS AT 6.25'/UNIT = 25'/ROW
SOIL ABSORPTION SYSTEM (PROFILE)
RESTORE VEGETATIVE COVER
BACKFILL WITH CLEAN PERC SAND
AND COMPACT THE 18" OF MATERIAL
ABOVE CHAMBERS FOR H2O LOADING
_� EXISTING SUITABLE
2.83 I MATERIAL
IE'1
EFFECTIVE WIDTH = 4 x 2.83' = 11.32
USE 4 ROWS OF 4 -HIGH CAPACITY
= INFILTRATOR (H20) UNITS W/ ENDCAP-NO STONE
��P��$ OF MA0S9��G
DARREN M.
o
<�G/SiE.R`O
S4NITAR�a�
TYPICAL SECTION
Kts
SOIL LOGS
DATE: APRIL 16, 2015
SOIL EVALUATOR: DARREN M. MEYER, RS, CSE 1614
WITNESS: AMY VONHONE, YARMOUTH HEALTH
Elev.
TP -1 Depth
19.5 0"
A
SANDY LOAM
119.0
10YR 3/2 61,
B
LOAMY SAND
IOYR 6/4
16.681-
34"
i
MEDIUM
PERC TEST SAND
0 14.5 2.SY 6/4
i
7!83 140"
PERC RATE <2 MIN/IN. ("Cl" HORIZON)
NO GROUNDWATER OBSERVED
• I, Darren M. Meyer, R.S., CSE, hereby certify that I am currently approved by MADEP pursuant to 310 CMR 15.017
to conduct sail evaluations and that the above analysis has been performed by me consistent with the
requirements of 310 CMR 15.017. 1 further certify that I have passed the Soil Eval. Exam in October, 1999.
GENERAL NOTES:
1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL
BOARD OF HEALTH AND THE DESIGN ENGINEER.
2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS
OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE
LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED ON PAGE 1.
3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR
TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE
DESIGN ENGINEER.
4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING
FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN
ENGINEER BEFORE CONSTRUCTION CONTINUES.
5. ALL ELEVATIONS BASED ON ASSUMED DATUM.
6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF
THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF
HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION.
7. DWELLING IS SERVICED BY TOWN WATER, SERVICE TO BE RE -LOCATED.
LINE TO BE SLEEVED FOR ENTIRE LENGTH. WATER DEPT APPROVAL REQ'D.
8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED
TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR.
9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE
LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO STARTING WORK.
10. EXISTING LEACHING TO BE PUMPED, CRUSHED AND REMOVED PER TITLE 5.
REPLACE WITH CLEAN MEDIUM SAND PER TITLE 5.
11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION
12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY
AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY
13. NO KNOWN PRIVATE WELLS WITHIN 100 F. OF PROPOSED LEACHING
14. ALL PIPING TO BE 4" SCH 40 0 1/8"/FT (UNLESS SPEC. )
15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW
FOR THE USE OF A GARBAGE GRINDER.
16. NO WETLANDS WITHIN 150 FT. OF PROPOSED LEACHING
17. PLACE 40 ml POLY LINERS AS SHOWN FROM ELEV. 17.0 - 13.0
TO PREVENT INFILTRATION.
SECTION
11,
INVERT
HEIGHT END CAP
INFILTRATOR - HI CAPACITY (H2O) CHAMBER
PROPOSED SEPTIC SYSTEM UPGRADE PLAN
32 MASSACHUSETTS AVENUE, WEST YARMOUTH, MA
Prepared for: Ricci
System Design and Site Plan by: SCALE DRAWN DATE
MEYER & SONS, INC. N.T.S. DMM
PO BOX 961
E,4STSANDWICH,MA02537 DATE CHECKED SHEET NO.
508-362-2922 05/07/15 DMM 2 of 2