Loading...
HomeMy WebLinkAboutEngineered Plan - Rev. 2015***INSTALLER SHALL CONFIRM EXISTING 3 FLOW DIFFUSORS WITH 2' STONE ALL AROUND SYSTEM PROFILE (NOT TO SCALE) EXISTING—PROPOSED TOP PRECAST EL. 13.96 ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. 1 CONCRETE COVERS TO WITHIN 3" GRADE 2% SLOPE REQUIRED OVER SYSTEM MORTAR ALL COMPONENTS (TYP.) 8.0' °°O°0°O°O°80808000800°0°0°80°°°°O°O°O000 00° 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 EXISTING (3) FLOW DIFFUSORS*** o 0 0�0�0�0 0�0�0 0 0 0�0 0 0�0�0�0 0, 0-0�0 PROPOSED (2 ADDITIONAL) FLOW DIFFUSORS o INV. EL. MATCH EXISTING *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL APPROX. 13.42* UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATION PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT 1000 GALLONS AND ITS SUITABILITY FOR RE—USE. REPLACE WITH 1500 GALLON SEPTIC TANK APPROPRIATE TO SITE CONDITIONS IF NOT SUITABLE LEGEND 99— EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. 99 PROPOSED CONTOUR 99 PROPOSED SPOT EL. TH1 SEPTIC TANK: 440 GPD (2) = 880 TEST HOLE 2� SLOPE OF GROUND EXISTING LEACHING: UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING AUGER HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: AMY VON HONE, RS DATE: 4/16/15 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. 1 0" 4 16' A LS 8» 1OYR 3/2 B LS 26" 1OYR 4/4 13.8' C FS 2.5Y 7/4 126" I 15.5' NO GROUNDWATER ENCOUNTERED DICE #15-075 EXISTING POST&RAIL FENCE rn h 5.5' BOTTOM TH-1 NO GROUNDWATER FOUND :�•� ,� ��.' `yam.' A IN / MAP 61 PARCEL 7 &I AKIN AVE.) Scale: 1"= 20' 0 10 20 30 TOP PRECAST EL. 13.96 1 2" PEASTONE AND FILTER FABRIC OVER STONE s0000c 0 %000 3/4"-1-1/2" STONE �(03000 DOUBLE WASHED ,° °_ BOTTOM STONE ELEV. 11.42 f 40 i 50 FEET SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED EXISTING 3 BEDROOM, PROPOSED 4 BEDROOM . DESIGN FLOW: 4 BEDROOMS @ 110 GPD = 440 GPD USE A 440 GPD DESIGN FLOW Ro SEPTIC TANK: 440 GPD (2) = 880 � and S 5�• o�� **RE—USE EXISTING 1000 GAL. SEPTIC TANK EXISTING LEACHING: �z hoSP a� SIDES: (8 + (2)26) .96' (.74) = 43 GPD BOTTOM 8 x 26 (.74) = 154 GPD EXISTING TOTAL: 265 S.F. 197 GPD PROPOSED LEACHING: SIDES: (11+8.8+(2)19.5) 2' (.74) = 87 GPD BOTTOM 11 x 19.5 (.74) = 159 GPD PROPOSED TOTAL: 332 S.F. 246 GPD TOTAL: 197 + 246 = 443 GPD ADD (2) 4'x8' FLOW DIFFUSERS WITH 3.5' STONE ALL AROUND AND 1.04' BELOW DATE LOCUS MAP NOT TO SCALE ASSESSORS MAP 61 PARCEL 6 NOTES 1. DATUM IS NGVD MA 2. MUNICIPAL WATER IS EXISTING BOARD OF HEALTH 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE M1 PROPOSED LEACHING FACILITY. N zae > A�k OF M,gSS C , t' DANIEL A. OJALA q No. 40980 � e / �°� �fiSS% —L C:)/� DANIEL A. OJALA, P.E., P.L.S. TITLE 5 SITE PLAN OF 7 AKIN AVENUE SOUTH YARMOUTH, MA PREPARED FOR ANN LEONARD DATE: APRIL 21, 2015 REV: MAY 29, 2015 (SAS DETAIL) off 508-362-4541 fax 508-362-9880 downcope.com @ down cape engineering, inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 D L cus Ro � and S 5�• o�� Q+�S 0 Oda 5 �z hoSP a� Jc 0 h LOCUS MAP NOT TO SCALE ASSESSORS MAP 61 PARCEL 6 NOTES 1. DATUM IS NGVD MA 2. MUNICIPAL WATER IS EXISTING BOARD OF HEALTH 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE M1 PROPOSED LEACHING FACILITY. N zae > A�k OF M,gSS C , t' DANIEL A. OJALA q No. 40980 � e / �°� �fiSS% —L C:)/� DANIEL A. OJALA, P.E., P.L.S. TITLE 5 SITE PLAN OF 7 AKIN AVENUE SOUTH YARMOUTH, MA PREPARED FOR ANN LEONARD DATE: APRIL 21, 2015 REV: MAY 29, 2015 (SAS DETAIL) off 508-362-4541 fax 508-362-9880 downcope.com @ down cape engineering, inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675