Loading...
HomeMy WebLinkAboutEngineered Plans - 2015LEGEND N Hili Rd --100-- EXISTING CONTOUR ® Debs 96 PROPOSED CONTOUR ° x 100.98 EXISTING SPOT GRADE CD W EXISTING WATER SERVICE f'B qs) � Rd Mir1Oh o. Dr —G EXISTING GAS SERVICE —O. H. W= OVERHEAD WIRES ID U °sf Hill LOCUS TEST PIT Ra BENCHMARK °� � LOT 38 R°utis 6 LOT 37 S \t1"\ties ---- S 15'54'00" E LOCUS MAP — -75.02' + NOT TO SCALE LOT 27 LOT 30 _-MSL 107-43��,� J4,683 ±SF x 92.94 x 95.65 `�---_ x 95.13 \ LOT 28 96 w __ -1 stockade 0 \ Fence �� 10 x 98.81 1--� � �� '••' 33.5' 97.42 LOT 31 _ - •- 291 98:3 :I rn 0 0 O � 99.57 X + 101.02 i EXISTING LEACH PIT /100.97 (PER RECORD AS–BUILT) TO BE PUMPED, FILLED W/SAND & ABANDONED 101.57 101.52 EXISTING SEPTIC TANK TOP OF TANK, EL. = 99.87 B M INV. (OU I)= 98.54f 101.40 : DECK BENCHMARK COR./BULKHEAD SEX/STING EL. =101.40 101.8 HOUSE(#50) C) 101 LOT 29 1 1.9 101.6 � • 1 101.54 x .100,59 WALK s . -__:bath ]health Departm�rti ,� :� VED 101,55 x ...:; � _ 100.89., - 10 , 100.78 x ¢� OVA Y ame = Date I 100.63 - -i ,:. x=33 : 0'.. i 41.30' 100.52R -2g .• 13'. N 15'54'00/"U.P, H. W--'—- 101,08 H; CATCH �� OF MASS BASIN 99,02 edge of pavement 96,87 95.72 OWNER OF RECORD q�yG o ER T. RHINE LOAD DAVIS, TODD W DAVIS, MICHELLE L PET MCENTEE 50 RHINE ROAD o CIVIL "' YARMOUTHPORT, MA 02675 No. 35109 o��F £G/STE PROPOSED SEPTIC SYSTEM UPGRADE PLAN 50 RHINE ROAD, YARMOUTHPORT, MA Prepared for: D. A. Brown, Inc., P.O. Box 145, Centerville, MA 02632 (CIl Engineering by: SCALE DRAWN JOB. NO. HOUSE LOCATION TAkEN FROM FOUNDATION AS -BUILT PLAN BY Engineering Works, Inc. 1"=20' P.T.M. 254-14 FLAHERTY ASSOCIATES, 170 COURT STREET, PLYMOUTH, MA 02360, 12 West Crossfield Road, Forestdole, MA 02644 DATE CHECKED SHEET NO. DATED 6/29/90. (508) 477-5313 1/30/15 P.T.M. 1 of 2 NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL:96.0 FOR A DISTANCE OF 15' AROUND THE SEPTIC TANK PROPOSED D -BOX PERIMETER OF THE S.A.S. INSTALL RISERS & COVERS OVER INLET & OUTLET AND SET TO 6' OF FINISH GRADE INSTALL RISER &COVER PROPOSED S.A.S. SET TO 6" OF GRADE INSTALL RISER & COVER OVER EACH CHAMBER AND T.O.F. SET TO 3' OF F.G. TO SERVE AS INSPECTION PORTS F.G. EL.=100.7± F.G. EL.=100.6± F.G. EL.=99.3± F.G. EL.=99.3(max.) 3'(max.) L = 20' =23' ® S=1% (MIN.) ® S=1%(MIN.) 4"SCH40 PVC 4"SCH40 PVC 2" LAYER OF 1/8" TO 1/2" DOUBLE WASHED STONE " ��"i 6 aaaS0B0 (OR APPROVED FILTER FABRIC) 7s"~ 14" B®8B®B6 EXISTING 48" LIQUID BBaaaaa -3/4" TO 1-1/2" DOUBLE LEVEL ADD PROPOSED 4' 4.8' 4' WASHED STONE GAS eAFFLE INV.=97.17 INV.=97.00 D -BOX EFFECTIVE WIDTH = 12.8' INV.=98.54± EXISTING 3 OUTLETS INV.=95.50 EXISTING SEPTIC TANK 3-500 GALLON LEACHING CHAMBERS SURROUNDED WITH STONE AS SHOWN H-10 RATED TOP CONC. ELEV.=96.3± NOTES: BREAKOUT ELEV.=96.00 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INV. ELEV.=95.50 aaaB INVERTS, PRIOR TO INSTALLATION. E300M eases 2) D -BOX SHALL BE SET LEVEL AND TRUE TO BOTTOM ELEV.=93.50 4 GRADE ON A MECHANICALLY COMPACTED SIX 4' OF NATURALLY OCCURRING INCH CRUSHED STONE BASE, AS SPECIFIED EFFECTIVE LENGTH = 35.5' - PERVIOUS MATERIAL IN 310 CMR 15.221(2). / 5' (MIN.) ABOVE G.W. �' 3) INSTALL INLET & OUTLET TEES AS REQUIRED. LEACHING SYSTEM SECTION 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE BOTTOM OF TP, EL.=88.4 AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. (NO GROUNDWATER) j7 / �p� per•/ /`�, C/ SEPTIC SYSTEM PROFILE SOIL LOG GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL DATE: DECEMBER 17, 2014 SOIL EVALUATOR: PETER McENTEE PE(SE#1542) BOARD OF HEALTH AND THE DESIGN ENGINEER. WITNESS: AMY VON HONE R.S. HEALTH AGENT 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS TP OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE ELEV. DEPTH LOCAL RULES AND REGULATIONS. 0" 98.5 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR FILL TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE 98.0 6" DESIGN ENGINEER. A LOAMY SAND 10YR 4/2 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING 97.3 14" FROM THOSE _SHOWN HEREQN-SHALLBE REPORTED -IO. -THE -DESIGN-_ __ _-___ ___ _ _. _ _ B LOAMY -SAND}-- - PERC ENGINEER BEFORE CONSTRUCTION CONTINUES. 10YR 5/8 24"/36" 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 95.5 36" 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF C1 THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF BOULDERS HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. FINE SAND THROUGHOUT 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 2.5Y 6/6 B & C HORIZONS 8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S. 88.7 118 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS C2 AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE LOAMY SAND DIRECTED BY THE APPROVING AUTHORITIES. 2.5Y 6/4 88.4 121" 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY PERC RATE MIN/IN. HORIZONS) THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING <2 ("B/C" CONSTRUCTION. NO GROUNDWATER ENCOUNTERED 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL. BACK 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND NOT CONSIDERED TO BE A PROPERTY LINE SURVEY. D CK �t o DESIGN CRITERIA �rb s� to NUMBER OF BEDROOMS: 4 BEDROOMS SOIL TEXTURAL CLASS: CLASS I (LOADING RATE=0.74 GPD/SF) DESIGN PERCOLATION RATE: <2 MIN/IN 11 PROPOS ED S.A.S DAILY FLOW: 440 GPD N DESIGN FLOW: 440 GPD 33_ GARBAGE GRINDER: NO -not allowed with design LEACHING AREA REQUIRED: (440 GPD) = 594.6 SF p S.A.S. LAYOUT .74 GPD/SF PROPOSED SEPTIC TANK: 1500 GALLON CAPACITY (H-20) PROPOSED SEPTIC SYSTEM UPGRADE PLAN PROPOSED D -BOX: 1 INLET, 3 OUTLET (MINIMUM), H-20 RATED USE 3-500 GALLON LEACHING CHAMBERS IN SERIES 50 RHINE ROAD, YARMOUTHPORT, MA SURROUNDED BY DOUBLE WASHED STONE ON ALL SIDES SIDEWALL AREA: 2(12.8' + 335) X 2 = 185.2 S.F. Prepared for: D. A. Brown, Inc., P.O. Box 145, Centerville, MA 02632 Engineering by: SCALE DRAWN JOB. NO. BOTTOM AREA: 12.8' x 33.5' = 428.8 S.F. ' Engineering Works, Inc. N.T.S. P.T.M. 254-14 TOTAL AREA: .............................................................. 614.0 S.F. DATE CHECKED SHEET NO. 12 West Crossfield Road, Forestdole, MA 02644 DESIGN FLOW PROVIDED: 0.74 GPD/SF(614.0 SF) = 454.4 GPD (508) 477-5313 1/30/15 P.T.M. 2 Of 2