HomeMy WebLinkAboutEngineered Plan - Rev. 2015I ALARM AND CONTROL PANEL 2'0 H-20 CAST IRON COVERS TO GRADE TO BE INSTALLED INSIDE _4B = 11.3' BED IN CONCRETE UP TO BINDER COAT PAVEMENT BUILDING. ALARM TO BE ON SEPARATE CIRCUIT FROM PUMP 10.0' PRECAST H-20 , \ . • .. RISERS (TYP.) INV. IN 6.89 2'0 FL­Lil3 *8.2'f TEE SETTINGS: ALARM ON 1000 GAL. H-20 S/T 7.33'7.26' TEE 24* 7'08' 500 GAL.+ 24" PUMP ON RESERVE TEE 8„ GAS BAFFLE :. 4" WORKING RANGE (2 5 % SLOPE) , 916 GAL COMP. 534 GAL COMP. OF -TRE EF -4 4" 6.0' 3.5' EFFLUENT FILTER ., (OR EQUAL) PUMP OFF 8 ,. .. ;. .. 7W/MOLDED IN GAS o' u0••u0 v0 u0 v0 u0 u10 u 0 •u u •u v u u u v0 0 0 0 0 0 0 0 u0 u0 u0 u L DEFLECTOR J 0 000000 �ppOO�O 0 0 ( 0000000000000000000000000000000000000000000p . 0 000 n000000?0?n°n°n°n,� 0000o00000o('ononononoo00°0. 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [21) (--L-% % SLOPE) WATERPROOF/WATERTIGHT I WATERPROOF/WATERTIGHT - in, - PUM HAM B P C ER FOUNDATION 35 *THE INSTALLER SHALL VERIFY THE .LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC. SYSTEM NOTES 1 . __r -1 - 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -M 5. PIPE JOINTS TO BE. MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 13. TANK AND PUMP CHAMBER TO BE WATERPROOF/WATERTIGHT. LEGEND- EGEND99- 99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. 99 PROPOSED CONTOUR [98.4] PROPOSED SPOT EL. TH 1 (NOT TO SCALE) } TEST HOLE 2� SLOPE OF GROUND C -OLD UTILITY POLE 1/2" x 5 1 4" FIRE HYDRANT OCATCH BASIN W WATER LINE E- ELECTRIC LINE -X- X- FENCE NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING DCE ## 15-021 20 SEPTIC TANK - H-20 PROP. WATERTIGHT COVER TO GRADE i i SYSTEM PROFILE MARK CORNERS OF LEACHING FIELD W/ 2% MIN. SLOPE OVER SYSTEM MIN. LOT FRONTAGE REBAR SET 4" BELOW VENT W/ CHARCOAL FILTER 4" LOAM &SEED T.O.W. = 10.3' PROVIDE QUICK DISCONNECT FOR PUMP (NOT TO SCALE) GRADE INSPECTION PORT (SEE DETAIL) 2% SLOPE 30"± CAP STONE UNITS ACCESS COVERS TO GRADE 4" H-20 RIM AND COVER 20' 1/2" x 5 1 4" 25% SITE FILTER FABRIC SEE WALL DETAIL �_IIII�I_II - Fiberglass H-20 LOW PROFILE D -BOX F1_07.7 TOP 9.95' FINISHED GRADE- 4" LOAM & SEED OR PAVE AS REQ.I-111-_ 9" COVER 111 II- IIV-11-- Pins 10,0' MINIMUM .75' OF COVE / 10.9 "OSCH40 PVC FILL AS 5'MIN. VAR ES -I-vT�iXi\i,��� CLEAN " ay����% 1 PIPES LEVEL 1ST 2' :.•.,... _• :.•...,. E T ,•..,.:. ,o ..• CONN CT AND VEN pEASTONE 4" PERFORATED PVC 3' O.C. S=0.005 COARSE SAND BACKFILL AGAINST 2" PRESSURE LINE TO PC o SLOPE TO DRAIN BACK 000000000000 WATERTEST D'BOX +?0�°000�0°,04• FOR LEVELNESS R L 3/4"-1-1/2" DOUBLE WASHED 8" STONE LEACHING FIELD o0 6"DEPTH WALL MIN BELOW INV. ,• 40 MIL LINER FROM TOP PEASTONE/WALL ti? �� 9.84' 9 9.64 ' 9.50 LEVEL BOTTOM o TO 12 BELOW GRADE 0.25 WEEP HOLES CHECK VALVE 1 . KEYSTONE OR EQUAL RETAINING WALL UNITS 28 0' 18"X8" SET WITH 1" BATTER PER ROW DUAL MYERS SRM 4FIBERGLASS PINS REQ. 6"X30" Crushed Rock or SUBMERSIBLE 4/10 HP PUMP 9.0'IF SYSTEM (OR EQUAL) 5.0' 000 USE ADJUSTED RETAINING V 6" CRUSHED STONE OR MECHANICAL GROUNDWATER ®EL. 4.0 i COMPACTION. (15.221 [21) SLOPE) LOW PROFILE SYSTEM DESIGN: 35' D' BOX 5' LEACHING H-20 2,498 S.F. SUPERMARKET @ 97 GPD/1000 S.F. = 243 GPD TOTAL DESIGN FLOW = 243 GPD SEPTIC TANK: 243 GPD (2) = 486 (FIRST COMPARTMENT) 243 GPD (1) = 243 (SECOND COMPARTMENT) j 0 25 50 75 100 CAPACITY - GPM PUMP CURVE FOR MYERS SRM4 4/10 HP PUMP DATE DANIEL A. OJALA, P.E., P.L.S. I 486 + 243 = 729 GAL. REQUIRED I USE A 1500 GAL. DUAL COMPARTMENT SEPTIC TANK, w LEACHING: 243 GPD (.74) = 329 SF REQUIRED 12'X23'=336 SF OK 336 SF X .74 = 249 GPD OK USE A 12' X 28' PIPE AND STONE LEACHING FIELD G -W ADJ. DATA: WELL: MIW 29 ZONE: A ADJ: 1.6' (JANUARY) USE 1.0' TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS' AMY VON HONE, RS DATE: 2/18/15 -. PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. ELEV. 011 Q 10.0' 0„ Q 10.0' FI LL FI LL C1 FS 2.5Y 5/4 C2 CS & GRAVEL 1OYR 5/3 C3 FS 2.5Y 5/6 48" 6.0' 54" C1 FS 4.0' ADJ GW 2.5Y 5/4 84" 3.0' 84" C2 CS & GRAVEL 96" 1OYR 5/3 2.0' 96" SIEVE C3 FS 2.5Y 5/6 120" 0.0' 120" 5.5' GROUNDWATER ENCOUNTERED @ 84" EL. 3.0 12.0' .5 3.0• O N SEPTIC DETAIL SCALE 1 " = 10' 3.0' 2.0' 0.0' Unreinforced Concrete Leveling Pad req. .L CROSS SECTION NOT TO SCALE LOCUS MAP - - NOT TO SCALE ASSESSORS MAP 42 PARCEL 39 LOCUS IS WITHIN FEMA FLOOD ZONE AE EL. 11 AS SHOWN ON COMMUNITY PANEL #25001 CO587J DATED 7/16/2014 ZONING SUMMARY ZONING DISTRICT: 62 BUSINESS DISTRICT MIN. LOT SIZE 20,000 S.F. MIN. LOT FRONTAGE 125' MIN. FRONT SETBACK 30' MIN. SIDE SETBACK 25' MIN. REAR SETBACK 20' MAX. BUILDING COVERAGE 25% SITE IS LOCATED WITHIN HMOD1 AND VC4 OVERLAY DISTRICTS NER OF RECORD SOUTHLAND CORP 1011 ROUTE 28 SOUTH YARMOUTH, MA 02664 REFERENCES DEED BOOK 4450 PAGE 314 PLAN BOOK 167 PAGE 93 VARIANCES REQUESTED: UNDER TOWN OF YARMOUTH HEALTH REGULATIONS: REDUCTION IN GROUNDWATER ADJUSTMENT 1.6' TO 1.0' TITLE 5. S��TE P SOU YARMOUTH, MA_ PREPARED FOR A TO Z CONVENIENCE to I I iZoul-e Z'11' DATE: APRIL 2, 2015 REV: MAY 5, 2015 (BASIN/SAS SIZE) Scale:1 "= 20' 0 10 20 30 40 50 FEET .Permit: valid for REPAIR 01" SEPTIC SVS" EN1 `ONLY, due to State and Local septic .variances. Board `of llealth review and approval is required for any, •future additions/�.enuvations/alterations to sewage facilities and/or structures/dwelling. :Yarmouth -.health Department APPROVED/o off 508-362-4541 fax 508-362-9880 downcope.com Vrn cape entiaeering, inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675