Loading...
HomeMy WebLinkAboutEngineered Plan - 2015CONTRACTOR SHALL IMPROVE ALL DISTURBED AREAS WITH 6' LOAM AND HYDROSEED COSTING TREE TO BE REMOVED AND REPLANTED (2) DOSING PINES i REWIRED PROVIDED DAILY FLOW 3 BEDROOMS O 110 GDP/BEDROOM SEPTIC TANK: TO BE REMOVED / 330 GPD x 20OX (TITLE 5) 660 GAL 1500 GAL (TITLE 5 REGULATION) X,6.19 x36.81 FEATURES LEACHING AREA: 2`V'x12' SURFACE ELEV. 97 (USDA) 148 SF BOTTOM: 25'x 2' EOSTNC CESSPOOLS ' O TOTAL I cpGHING 448 SF AND PIPING TO BE PUMPED AND REMOVED 3�/ 109.5 GPD N/F 35.47 (TYP OF 2) m i D 330 GPD THE MILDRED C PERONE NONE 16-31 i D B REVOCABLE TRUST OF 2015 10 YR 6/6 NONE NONE `I GILBERT BASS, SUCCESSOR Cl MEDIUM SAND 6.03 NONE NONE 53-62 31.63 sone:"NTo MEDIUM SAND TRUSTEE NONE NONE 62-125 G MAP 89 LOT 165 FINE SAND 2.5 Y 8/2 NONE AT PIPE "75 RITA AVE" (2) EOSTNG PINES ; SLOT `EX. AREA=10,000 S.F TO BE REMOVED w PORCH O EX. INV (0.23 AC) PROPOSED 1300 I F:=38.4 OUT=36.1 GALLON SEPTIC TANK (SHOREY (SHOREY PRECAST OR i O n EXISTINGW W- APPREQUAL) n 10.5 (FULL BASEMENT) 36.3 24.5' 37 (COVERED CLEANOUT I C/O (COVER TO THINGRA ED D OF FINISHGRADE) E) I ao m o EX. PORCH (SLAB) :: - G 3... 5189 o Z PROPOSED 2 --OUTLET / O .� xJ7.23 10.1' 1-2o DISTRIBUTION BOx 1 COSTING TREE (SHOREY PRECAST -EX. / GARAGE DB -3-H-20 OR APPROVED EWAL) REMOVED AND (SLAB) EX DRIVEWAY ..: �. RECANTED EXISTING TREE TO BE REMOVED i '• 1 37.69 . :':'• 10.2' x3fi.3 36 I x37.57 py EX. SHED �i A NO SLAB CONTRACTOR m REPLACE (2) I n SECTIONS OF EOSDNG STOCKADE T FENCE DISTURBED FOR MACHINE ACCESS 3 39 37.80 1 579.15.20'W 100.00' PROPOSED 23'x12' SPL ABSERPnDN sYsrEM TH Soo `'ALLEN `EAC NG tl7AwN (SHOREY PRECAST OR SEPTIC SYSTEM MINIMUM SETBACKS APPROVED EOUAL) LEACHING FACILITY SEPTIC TANK SEE SEPTIC SYSTEM PROFILE PROP FeR LINES 10: PROP$RTY IAATION 1O OWUAhTION?0 LA W BENCHMARK //-- MAGNAIL IN PAVEMENT / ELEV=37.88 (NAVD88) DESIGN FORMULA: NO GARBAGE GRINDER ALLOWED 'NTH THIS DESIGN SYSTEM - REWIRED PROVIDED DAILY FLOW 3 BEDROOMS O 110 GDP/BEDROOM SEPTIC TANK: 330 GPD DATE 330 GPD x 20OX (TITLE 5) 660 GAL 1500 GAL (TITLE 5 REGULATION) 1500 GAL FEATURES LEACHING AREA: 2`V'x12' SURFACE ELEV. 2 EFFECnv� Ep SIDEWALL• 2 x 2 x 25'+12')) (USDA) 148 SF BOTTOM: 25'x 2' 300 SF TOTAL I cpGHING 448 SF CAPACITY: SIDEWALL: 148 SF x 0.74 GAL/SF 109.5 GPD BOTTOM: 300 SF x 0.74 GAL/SF2220 35.47 GPD TOTAL. 330 GPD 331.5 GPD DEEP TEST HOLE #1 - ELEVATION=36.8'f DEPTH BOTTOM PERCOLATION TEST BY: SOIL SOIL - REDOXIMORPHIC DATE FROM OF LAYER SOIL TEXTURE COLOR FEATURES OTHER SURFACE ELEV. HORIZON (USDA) (MUNSELL) (MOTTLES) (INCHES) (FEET) 0-16 35.47 A SANDY LOAM 10 YR 5/1 NONE NONE 16-31 34.22 B SANDY LOAM 10 YR 6/6 NONE NONE 31-53 32.38- Cl MEDIUM SAND 10 YR 7/3 NONE NONE 53-62 31.63 C2 MEDIUM SAND 10 YR 6/4 NONE NONE 62-125 26.38 C3 FINE SAND 2.5 Y 8/2 NONE NONE TEST PIT LOG AND Designed by : PGB Drawn by : PGB Checked by: RJT Survey chk. by : PGB Approved by : EHG PERCOLATION TEST BY: SCOTT MCGANN, CERTIFIED SOIL EVALUATOR, SE X12761 WITNESSED BY: AMY VONHONE, TOWN OF YARMOUTH BOARD OF HEALTH DATE JUNE 10, 2015 PERCOLATION RATE f2 MIN/INCH AT 73' NO WATER ENCOUNTERED (2) -500 -GALLON LEACHING CHAMBERS NOTE: THE FINISH GRADE ABOVE THE SOIL 3 -OUTLET H-20 DISTRIBUTION BOX SHOREY PRECAST LD -500 ABSORPTION SYSTEM SHALL HAVE A MINIMUM SHOREY PRECAST DB -3 H-20 (OR APPROVED EQUAL) SLOPE OF 2% TO REDUCE INFILTRATION AND 1,500 GALLON SEPTIC TANK OR APPROVED EQUAL -SOIL ABSORPTION SYSTEM- TO MINIMIZE EROSION. ( ) PROVIDE CONCRETE RISER SHOREY PRECAST (OR APPROVED EQUAL) -DISTRIBUTION BOX- AND COVER TO WITHIN 6' TOP OF SYSTEM -SEPTIC TANK- OF FINAL GRADE FFT.--_V. 34.25 EX. PORCH SLAB PROVIDE CONCRETE RISER AND COVER TO WITHIN 6' PROVIDE 2' OF a' TO }" ELEV. = 38.4' OF FINISHED GRADE WASHED STONE (TYP) PROVIDE 3' OF 1 DOUBLE 3' MAX. COVER3Z2•* F.G.-36.5'* TO 37.0WASHED STONE (TYP) 9 MIN. COVER. 36.T EXISTING SEWER 3' MAX. COVER UNE OUT OF 9' MIN. COVER 6' SUMP BUILDING OUT MIN. MIN. 6.1' EX. IN OUTLET TEE-,�. Q'.'. 4,�'.. : O. Q'. 4•�'.. C7. 7-:iti.. 2, 3. • OUT- IN- EFFECTIVE OUT s .v.:. e• •'. ELEV. 10' :aw:?:.%:i '.L7•: LZ. Cl:`O' 'LT':L}'.Q C�:`0'' ':.:.••... :. EFFECRVE NOMINAL '`::� •.'I•z%`t+: DEPTH DEPTH MIN MIN :x .:w;i 0.• �. O'..� °El 13.. lnq. 0. b °m. - SYSTEM .OEM 4" PVC O 4' PVC O 1X MIN. INVERT INTO CHAMBERS BOTTOM OF SYSTEM INLET TEE 1X MIN. 4 ELEV.=33.60' ELEV. 31.27' GAS BAFFLE (TYp) () 5' MINIMUM 34.50' SEPARATION TO ELEV 34.25' 33.78' GROUNDWATER ELEV. ELEV. V. 4' PVC O 25'* • ••PROVIDE LEVEL 6'• • 28'* 6' k 14'1 25' x 12' x 2' 2X (MIN) COMPACTED CRUSHED 5' STONE BENEATH SEPTIC(MIN)PROVIDE LEVEL 6' NOTES: TANK COMPACTED CRUSHED 1. THE OUTLET TEE IS TO BE FITTED WITH A 3. SEPTIC TANKS SHALL BE PROVIDED 4. PROVIDE FLOW EQUAUZERS STONE BENEATH GAS BAFFLE AND EFFLUENT TEE FILTER. USE NTH AT LEAST THREE 20' AT DISTRIBUTION BOX DISTRIBUTION BOX ZABEL MODEL OR APPROVED EQUIVALENT. DIAMETER MANHOLES WITH READILY OUTLET PIPE (TUF-TITE 2. SEPTIC TANK SHALL BE EMBOSSED WITH REMOVABLE IMPERMEABLE COVERS SL -4 SPEED LEVELER OR PROPOSED SEPTIC SYSTEM PROFILE SEAL STATING CONFORMANCE WITH ASTM OF DURABLE MATERIAL APPROVED EQUAL). (NOT TO SCALE) C 1227-93. GENERAL NOTES: 1. RECORD OWNER(S): THE MILDRED C PERONE REVOCABLE TRUST OF 2015 GILBERT BASS, SUCCESSOR TRUSTEE 75 RITA AVE SOUTH YARMOUTH, MA 02664 DEED BOOK 28789 PAGE 111 2. THE PROPERTY IS SHOWN AS LOT 165 ON THE TOWN OF YARMOUTH ASSESSOR'S MAP 89. 3. THE PROPERTY UES WITHIN THE R-40 (RESIDENTIAL) ZONING DISTRICT BASED UPON A REVIEW OF THE TOWN OF YARMOUTH ZONING MAP. 4. THE PROPERTY DOES NOT APPEAR TO UE WITHIN THE AQUIFER PROTECTION DISTRICT BASED UPON A REVIEW OF THE TOWN OF YARMOUTH ZONING MAP. 5. THE PROPERTY LINES DEPICTED HEREON ARE BASED UPON. PLANS AND DEEDS ON RECORD AND ARE NOT THE RESULT OF A BOUNDARY SURVEY BY ATLANTIC DESIGN ENGINEERS, INC. B. THE PROPERTY UES WITHIN FLOOD ZONE X (AREA DETERMINED TO BE OUTSIDE OF THE 0.2X ANNUAL CHANCE FLOODPLAIN) BASED UPON A RENEW OF THE FEDERAL EMERGENCY MANAGEMENT AGENCY (FEMA) FLOOD INSURANCE RATE MAP (FIRM) MAP NUMBER 25001CO587J, EFFECTIVE DATE JULY 16, 2014. 7. THE PROPERTY IS NOT LOCATED WITHIN A ZONE II BASED UPON A REVIEW OF THE MASSACHUSETTS GEOGRAPHIC INFORMATION SYSTEM, THE CAPE COD COMMISSION GEOGRAPHIC INFORMATION SYSTEM AND CORRESPONDENCE NTH THE TOWN OF YARMOUTH HEALTH AGENT. 8. THE EXISTING CONDITIONS, SHOWN HEREON, ARE BASED UPON A FIELD SURVEY BY ATLANTIC DESIGN ENGINEERS, INC. IN JUNE OF 2015. 9. THE VERTICAL DATUM IS BASED UPON NATIONAL GEODETIC VERTICAL DATUM OF 1988. 10. EXISTING SEPTIC SYSTEM INFORMATION IS BASED UPON A SEPTIC INSPECTION PERFORMED BY ROBERT PAOUNI SEPTIC SERVICE, DATED MAY 27, 2015 AND IS NOT THE RESULT OF A SUBSURFACE SURVEY BY ATLANTIC DESIGN ENGINEERS, INC. 11. EXISTING UTIUTY INFORMATION IS BASED UPON DIGSAFE MARKINGS AND IS NOT THE RESULT OF A SUBSURFACE SURVEY BY ATLANTIC DESIGN ENGINEERS, INC. LOCUS MAP SCALE 1'=1,000'* SEPTIC DESIGN NOTES: 1. ALL DIMENSIONS SHOWN ARE PERPENDICULAR TO PROPERTY LINES AND EXISTING STRUCTURES. 2 THE CONTRACTOR IS RESPONSIBLE FOR NOTIFYING DIG SAFE, THE TOWN OF YARMOUTH DPW, AND ALL UTILITY COMPANIES A MINIMUM OF 72 HOURS PRIOR TO CONSTRUCTION ACTIVITIES TO LOCATE ALL EXISTING UTILITIES. 3. ALL SYSTEM COMPONENTS SHALL BE INSTALLED IN COMPLIANCE WITH THE STATE SANITARY CODE TITLE 5 AND THE TOWN OF YARMOUTH BOARD OF HEALTH REQUIREMENTS. 4. ALL TIGHT JOINT (T.J.) PIPING SHALL CONSIST OF 4' POLYVINYL CHLORIDE (PVC) PIPE SCHEDULE 40 ALL PIPES ARE TO BE LAID ON FIRM BASE AND SHALL BE WATERTIGHT AND ALL CONNECTIONS AND JOINTS SHALL BE MECHANICALLY SOUND AND TIGHT. 5. THE DISTRIBUTION BOX SHALL BE WATER TESTED FOR LEVELNESS AT THE TIME OF INSPECTION. 6. THE CONTRACTOR SHALL VERIFY THE EXISTING PIPE INVERTS AT THE EXISTING BUILDING AND AT THE NEW SEWER UNE TIE IN PRIOR TO INSTALLATION. THE CONTRACTOR SHALL ENSURE THAT ALL REQUIRED MINIMUM SLOPES ARE MAINTAINED. 7. ALL DISTURBED AREAS SHALL BE LOAMED (6' COMPACTED DEPTH) AND SEEDED IMMEDIATELY UPON COMPLETION OF CONSTRUCTION. 8. ANY CHANGE OR ALTERATION TO THIS PLAN MUST BE APPROVED BY THE TOWN OF YARMOUTH BOARD OF HEALTH AND ATLANTIC DESIGN ENGINEERS, INC. 9. THE CONTRACTOR SHALL NOTIFY THE DESIGN ENGINEER AND THE TOWN OF YARMOUTH BOARD OF HEALTH FOR INSPECTION PRIOR TO BACK FIWNG THE SYSTEM. THE DESIGN ENGINEER SHALL CERTIFY THAT THE SEPTIC SYSTEM INSTALLATION CONFORMS WITH THE APPROVED DESIGN PLAN. 10. THERE ARE NO KNOWN WELLS PROVIDING WATER FOR HUMAN CONSUMPTION TO EXIST WITHIN 150 FEET OF THE PROPOSED SOIL ABSORPTION SYSTEM. 11. THE CONTRACTOR SHALL INSTALL MAGNETIC MARKING TAPE ABOVE ALL SYSTEM COMPONENTS IN COMPLIANCE WITH 310 CMR 15.221.12. 12. THE CONTRACTOR SHALL REPAIR ANY IRRIGATION THAT IS DISTURBED BY THE PROPOSED WORK. Plantic® DESIGN ENGINEERS INC. �� P.O. Box 1051, Sandwich, MA 02563 (508) 888 - 9282 Designed by : PGB Drawn by : PGB Checked by: RJT Survey chk. by : PGB Approved by : EHG SCALE„ 6., a * SE �E,9 PREPARED FOR: GILBERT BASS 40 SOLDIER FIELD PLACE BOSTON, MA 02135 PROPOSED SEPTIC DESIGN PLAN FOR 75 RITA AVE SOUTH YARMOUTH, MA 02664 JUNE 10 2015 sheet of 1 1 JOB NUMBER 2803.00 SCALE 1 = 10 D 3 Io z0 1 PGB 6 19 15 H-10 COMPONENTS DATE N0. BY DATE REVISION CONTRACTOR SHALL IMPROVE ALL DISTURBED AREAS WITH 6" LOAM AND HYDROSEED EXISTING TREE TO BE REMOVED AND REPLANTED N 79'15'20"E (2) EXISTING PINES i TO BE REMOVED 7(36.19 X36.81 i .97 i EXISTING CESSPOOLS O AND PIPING TO BE PUMPED AND REMOVED (TYP OF 2) / BULK rn / HEAD 6.03 N /F THE MILDRED C PERONE REVOCABLE TRUST OF 2015 GILBERT BASS, SUCCESSOR TRUSTEE MAP 89 LOT 165 "75 RITA AVE" LOT AREA=10,000 S.F (0.23 AC) W W EX. DRIVEWAY „1, DESIGN FORMULA: NO GARBAGE GRINDER ALLOWED WITH THIS DESIGN SYSTEM REQUIRED PROVIDED TIE INTO REDOXIMORPHIC 3 BEDROOMS ® 110 GDP/BEDROOM 330 GPD EXISTING SEPTIC TANK: - FEATURES 330 GPD x 200% (TITLE 5) SEWER PIPE 1500 GAL (TITLE 5 REGULATION) 1500 GAL (MUNSELL) AT SLAB (INCHES) O (2) EXISTING PINES 148 SF BOTTOM: 25, x12,300 35.47 TO BE REMOVED W M� I EX. PORCH EX. INV 16-31 34.22 C (SLAB) OUT=36.1 PROPOSED 1500 GALLON NONE 222.0 GPD F.F.=38.4 330 GPD H-20 SEPTIC TANK' (SHOREY PRECAST ( I C r- NONE EXISTING RESIDENCE ST -1500-H-20 OR C2 10.5' 10.YR 6/4 (FULL BASEMENT APPROVED EQUAL) 9 � 10.7 36.5 24.5' ' C3 FINE SAND 2.5 Y 8/2 � 357 a PROPOSED CLEANOUT C/O I v (COVER TO WITHIN 6" I v d OF FINISHED GRADE) I M o o 1 t; "� Zo,. �, a EX. PORCH € I Iw j : �' v a a' (SLAB) N 5189 33 PROPOSED 2 -OUTLET 7037.23 379/77 H-20 DISTRIBUTION BOX' EXISTING TREE (SHOREY PRECAST TO BE EX. GARAGE DB -3-H-20 OR cnp ..� REMOVED AND (SLAB) APPROVED EQUAL) REPLANTED N /F THE MILDRED C PERONE REVOCABLE TRUST OF 2015 GILBERT BASS, SUCCESSOR TRUSTEE MAP 89 LOT 165 "75 RITA AVE" LOT AREA=10,000 S.F (0.23 AC) W W EX. DRIVEWAY „1, DESIGN FORMULA: NO GARBAGE GRINDER ALLOWED WITH THIS DESIGN SYSTEM REQUIRED PROVIDED DAILY FLOW: REDOXIMORPHIC 3 BEDROOMS ® 110 GDP/BEDROOM 330 GPD SOIL SEPTIC TANK: COLOR FEATURES 330 GPD x 200% (TITLE 5) 660 GAL 1500 GAL (TITLE 5 REGULATION) 1500 GAL (MUNSELL) LEACHING AREA: (INCHES) 25'x12' 2' EFFECTIVE QE PH , , SIDEWALL: 2 x(: �215 +12 )) 148 SF BOTTOM: 25, x12,300 35.47 SF TOTAL: 10 YR 5/1 448 SF 'LEACHING CAPACITY: 16-31 34.22 SIDEWALL: 148 SF x 0.74 GAL/SF SANDY LOAM 109.5 GPD BOTTOM: 300 SF x 0.74 GAL/SF NONE 222.0 GPD TOTAL: 330 GPD 331.5 GPD DEEP TEST HOLE #1 - ELEVATION=36.8'± DEPTH BOTTOM SOIL SOIL REDOXIMORPHIC FROM OF LAYER SOIL TEXTURE COLOR FEATURES OTHER SURFACE ELEV. HORIZON (USDA) (MUNSELL) (MOTTLES) (INCHES) (FEET) 0-16 35.47 A SANDY LOAM 10 YR 5/1 NONE NONE 16-31 34.22 B SANDY LOAM 10 YR 6/6 NONE NONE 31-53 32.38 Cl MEDIUM SAND 10 YR 7/3 NONE NONE 53-62 31.63 C2 MEDIUM SAND 10.YR 6/4 NONE NONE 62-125 26.38 C3 FINE SAND 2.5 Y 8/2 NONE NONE TEST PIT LOG AND PERCOLATION TEST BY: SCOTT MCGANN, CERTIFIED SOIL EVALUATOR, SE #2761 WITNESSED BY: AMY VONHONE, TOWN OF YARMOUTH BOARD OF HEALTH DATE: JUNE 10, 2015 PERCOLATION RATE: G2 MIN/INCH AT 73" NO WATER ENCOUNTERED LOCUS MAP SCALE: 1"=1,000'± Mpa EXISTING TREE TO BE REMOVED VV t 37.69 E ti PROPOSED VENT 'J PIPING OUT OF 04 RISERS (TYP) a 10.2' �- X36.30 36 I X37.57 py SHED !G (NO SLAB) o CONTRACTOR TO REPLACE (2) (� - SEC11ONS OF EXISTING STOCKADE ' FENCE DISTURBED FOR MACHINE ACCESS 37.80 6.39 !-S79'15'20"w -� SEPTIC DESIGN NOTES: PROPOSED PROPOSED 25'x12' SOIL 100.00' MUSHROOM sTYLE ABSORPTION SYSTEM WITH 500 1. ALL DIMENSIONS SHOWN ARE PERPENDICULAR TO PROPERTY LINES CHARCOAL FILTER GALLON H-20 LEACHING BENCHMARK VENT CHAMBERS (SHOREY PRECAST SEPTIC SYSTEM MINIMUM SETBACKS MAGNAIL IN PAVEMENT AND EXISTING STRUCTURES. LD -500-H-20 OR APPROVED LEACHING FACILITY SEPTIC TANK ELEV=37.68 (NAVD88) EQUAL) 2. THE CONTRACTOR IS RESPONSIBLE FOR NOTIFYING DIG SAFE, THE SEE NOTE 13 AND SEPTIC 10' PROPERTY LINES 10' PROPERTY LINES TOWN OF YARMOUTH DPW, AND ALL UTILITY COMPANIES A MINIMUM SYSTEM PROFILE 20; CELLAR WALL 10, CELLAR WALL GENERAL NOTES: OF 72 HOURS PRIOR TO CONSTRUCTION ACTIVITIES TO LOCATE ALL 10 SLAB FOUNDATION 10 SLAB FOUNDATION EXISTING UTILITIES. 1. RECORD OWNER(S): THE MILDRED C PERONE REVOCABLE TRUST OF 2015 3. ALL SYSTEM COMPONENTS SHALL BE INSTALLED IN COMPLIANCE WITH GILBERT BASS, SUCCESSOR TRUSTEE THE STATE SANITARY CODE TITLE 5 AND THE TOWN OF YARMOUTH 75 RITA AVE BOARD OF HEALTH REQUIREMENTS. SOUTH YARMOUTH, MA 02664 DEED BOOK 28789 PAGE 111 4. ALL TIGHT JOINT (T.J.) PIPING SHALL CONSIST OF 4" POLYVINYL 1,500 GALLON H-20 SEPTIC TANK 3 -OUTLET H-20 DISTRIBUTION BOX (2) 500 -GALLON H-20 LEACHING CHAMBERS NOTE: THE FINISH GRADE ABOVE THE SOIL CHLORIDE (PVC) PIPE SCHEDULE 40 ALL PIPES ARE TO BE LAID ON SHOREY PRECAST ST -1500-H-20 SHOREY PRECAST DB -3 H-20 SHOREY PRECAST LD -500 H-20 ABSORPTION SYSTEM SHALL HAVE A MINIMUM 2. THE PROPERTY IS SHOWN AS LOT 165 ON THE TOWN OF YARMOUTH (OR APPROVED EQUAL) (OR APPROVED EQUAL) (OR APPROVED EQUAL) SLOPE OF 2% TO REDUCE INFILTRATION AND ASSESSOR'S MAP 89. FIRM BASE AND SHALL BE WATERTIGHT AND ALL CONNECTIONS AND JOINTS SHALL BE MECHANICALLY SOUND AND TIGHT. -SEPTIC TANK- DISTRIBUTION BOX- -SOIL ABSORPTION SYSTEM- TO MINIMIZE EROSION. PROVIDE CONCRETE RISER 3. THE PROPERTY LIES WITHIN THE R-40 (RESIDENTIAL) ZONING DISTRICT BASED 5. ALL SEPTIC SYSTEM COMPONENTS SHALL BE REQUIRED TO BE AND COVER TO WITHIN 6" PROPOSED VENT TOP OF SYSTEM UPON A REVIEW OF THE TOWN OF YARMOUTH ZONING MAP. DESIGNED TO WITHSTAND H-20 LOADING. ' OF FINAL GRADE ELEV.=34.25 PROVIDE CONCRETE RISER PIPES OUT OF PROPOSED MUSHROOM 4. THE PROPERTY DOES NOT APPEAR TO LIE WITHIN THE AQUIFER PROTECTION EX. PORCH SLAB PROVIDE 2" OF " TO STYLE CHARCOAL FILTER ELEV. = 38.4' AND COVER TO WITHIN 6 WASHED STONE (TYP) RISERS (TYP) DISTRICT BASED UPON A REVIEW OF THE TOWN OF YARMOUTH ZONING MAP. 6. THE DISTRIBUTION BOX SHALL BE WATER TESTED FOR LEVELNESS AT OF FINISHED GRADE VENT THE TIME OF INSPECTION. F.G.=37.3' PROVIDE J" OF 1 j DOUBLE 3' MAX. COVER F.G.=37.0' 5. THE PROPERTY LINES DEPICTED HEREON ARE BASED UPON PLANS AND DEEDS 7• THE CONTRACTOR SHALL VERIFY THE EXISTING PIPE INVERTS AT THE F.G.= 37.2'± F.G.=36.5'± TO 37.0' WASHED STONE (TYP) 9" MIN. COVER TO 36.7' ON RECORD AND ARE NOT THE RESULT OF A BOUNDARY SURVEY BY ATLANTIC EXISTING BUILDING AND AT THE NEW SEWER LINE TIE IN PRIOR TO EXISTING SEWER ° ° DESIGN ENGINEERS, INC. INSTALLATION. THE CONTRACTOR SHALL ENSURE THAT ALL REQUIRED LINE OUT OF ° _� ° 3 MAX. COVER6" SUMP °BUILDING OUT 9" MIN. COVER MIN. 6. THE PROPERTY LIES WITHIN FLOOD ZONE X (AREA DETERMINED TO BE OUTSIDEMINIMUM SLOPES ARE MAINTAINED. ° ° :..IOF THE .0.2% ANNUAL CHANCE FLOODPLAIN) BASED UPON A REVIEW OF THEOUTLET jEF 0 ` - 8. ALL DISTURBED AREAS SHALL BE LOAMED (6" COMPACTED DEPTH) IN�'� �'•. °' °' •'' °''�':� 2' 3' FEDERAL EMERGENCY MANAGEMENT AGENCY (FEMA) FLOOD INSURANCE RATE AND SEEDED IMMEDIATELY UPON COMPLETION OF CONSTRUCTION. ° ° e• °•' ° 36.1 EX. OUT-� IN-► -► °°- ' OUT r.; �" . 1p:' ' p : ° p ° ° .D'° 1p:. 'Q, ° p ` , .� °�, : ,•,, °O O ° u. °° . O O ELEV. 10 14 - �;: - ;,•• ° ° A ° YY ° - �•• -1 • EFFECTIVE NOMINAL MAP (FIRM) MAP NUMBER 25001C0587J, EFFECTIVE DATE JULY 16, 2014. MIN :ee • :' p. < C� . 0'd Q ' D '. :a.p ° 'Cj' p tl '� p '. DEPTH DEPTH MIN '� °'�•� °f•� '" ''`•� °'�'� 9. ANY CHANGE OR ALTERATION TO THIS PLAN MUST BE APPROVED BY 4" PVC CSD • °•'O•' ' 7. THE PROPERTY IS NOT LOCATED WITHIN A ZONE II BASED UPON A REVIEW OF ' a 4 PVC INVERT INTO CHAMBERS BOTTOM OF SYSTEM THE TOWN OF YARMOUTH BOARD OF HEALTH AND ATLANTIC DESIGN INLET TEE 1% MIN. 1% MIN. 4' ELEV=33.60' ELEV.=31.27' THE MASSACHUSETTS GEOGRAPHIC INFORMATION SYSTEM, THE CAPE COD ENGINEERS, INC. (TYP) 5' MINIMUM COMMISSION GEOGRAPHIC INFORMATION SYSTEM AND CORRESPONDENCE WITH GAS BAFFLE (NP) THE TOWN OF YARMOUTH HEALTH AGENT. ' 34.50' '°, ... , � . °• •$ . • •... °.: � � SEPARATION TO 10. THE CONTRACTOR SHALL NOTIFY THE DESIGN ENGINEER AND THE ELEV. 34.25 33.95 33.78 GROUNDWATER TOWN OF YARMOUTH BOARD OF HEALTH FOR INSPECTION PRIOR TO ' ° ° ° • • ° • ° • ° ° ° ° ° ° • ° • ° • ELEV. ELEV. ELEV. 8. THE EXISTING CONDITIONS, SHOWN HEREON, ARE BASED UPON A FIELD SURVEY BACK FILLING THE SYSTEM. THE DESIGN ENGINEER SHALL CERTIFY •A •°.•°.•••A••°••°•••, A••O ••°.••, °.•°.•°•••°• °•• 4" PVC ® 25'± » 28'± 6' & 14'± BY ATLANTIC DESIGN ENGINEERS, INC. IN JUNE OF 2015. THAT THE SEPTIC SYSTEM INSTALLATION CONFORMS WITH THE PROVIDE LEVEL 6 25' x 12' x 2' APPROVED DESIGN PLAN. 2% (MIN) COMPACTED CRUSHED -~ 5' 9. THE VERTICAL DATUM IS BASED UPON NATIONAL GEODETIC VERTICAL DATUM OF PROVIDE LEVEL 6 STONE BENEATH SEPTIC » (MIN) NOTES: 1 1988, 11. THERE ARE NO KNOWN WELLS PROVIDING WATER FOR HUMAN TANK COMPACTED CRUSHED 1. THE OUTLET TEE IS TO BE FITTED WITH A 3. SEPTIC TANKS SHALL BE PROVIDED 4. PROVIDE FLOW EQUALIZERS CONSUMPTION TO EXIST WITHIN 150 FEET OF THE PROPOSED SOIL STONE BENEATH GAS BAFFLE AND EFFLUENT TEE FILTER. USE WITH AT LEAST THREE 20" AT DISTRIBUTION BOX 10. EXISTING SEPTIC SYSTEM INFORMATION IS BASED UPON A SEPTIC INSPECTION ABSORPTION SYSTEM. DISTRIBUTION BOX ZABEL MODEL OR APPROVED EQUIVALENT. DIAMETER MANHOLES WITH READILY OUTLET PIPE (TUF-TITE PERFORMED BY ROBERT PAOLINI SEPTIC SERVICE, DATED MAY 27, 2015 AND IS REMOVABLE IMPERMEABLE COVERS SL -4 SPEED LEVELER OR NOT THE RESULT OF A SUBSURFACE SURVEY BY ATLANTIC DESIGN ENGINEERS, 12, THE CONTRACTOR SHALL INSTALL MAGNETIC MARKING TAPE ABOVE 2. SEPTIC TANK SHALL BE EMBOSSED WITH OF DURABLE MATERIAL. APPROVED EQUAL). INC. ALL SYSTEM COMPONENTS IN COMPLIANCE WITH 310 CMR 15.221.12. PROPOSED SEPTIC SYSTEM PROFILE SEAL STATING CONFORMANCE WITH ASTM 11. EXISTING UTILITY INFORMATION IS BASED UPON DIGSAFE MARKINGS AND IS NOT 13. THE CONTRACTOR SHALL REPAIR ANY IRRIGATION THAT IS DISTURBED (NOT TO SCALE) C 1227-93. THE RESULT OF A SUBSURFACE SURVEY BY ATLANTIC DESIGN ENGINEERS, INC. BY THE PROPOSED WORK. .�pF �a RIC Af FILE: 2803.00 -SEPTIC Designed by : PGB SCALE T �'' PREPARED FOR: PROPOSED SEPTIC DESIGN PLAN sheet of ® y ® Drawn by . PGB _ " '3 GILBERT BASS FOR INC.o SCALE 1 - 10 20 `'" 75 RITA AVE DESIGN ENGINEERS, Checked by : RJT 5 10 S, �A► EN'° ��` 40 SOLDIER FIELD PLACE JOB NUMBER Survey cnk. by : PGB _ SOUTH YARMOUTH, MA 02664 P.O. Box 1051, Sandwich, MA 02563 (508) 888 - 9282 Approved by : EHG "` DATE NO. BY DATE REVISION BOSTON, MA 02135 JUNE 10, 2015 •