Loading...
HomeMy WebLinkAboutEngineered Plans - 2015LOCUS DATA 6 CURRENT OWNER JEFFREY T. MARR �7K0Fk4 DEBORAH M. MARK ���oPo �y� N EDWARD,Cy�N� I \ ' !i/ `� — — — Q� 0 A. 29 / �� PLAN REFERENCE 158-119 C) o y STONE N / . fop �o No. 28980 DEED REFERENCE 19851-148 LOCUS RFs / Q T Ss29 X28_ — — — — — — — _ ZONING DISTRICT R-40 LOCUS MAP FLOOD ZONE X NOT TO SCALE: ASSESSORS MAP 78 15-0108 UTILITYPOLE PARCEL 112 r / IN,EXISTING �\ _ OVERLAY DISTRICT ZONE it — APD DRIVEWAY PROPOSED S.A.S. �N V<v / LOT AREA 14,870± S.F. (24) QUIK "4"S. N INFILTRATOR 11.33'x24.0' SITE & SEWAGE i REPAIR PLAN LOT 60 29 PATIO GARAGE\ -�– 4 0 14.4 OBS 29 i SLAB AERN�� J 01130 CA P T. BACON ROAD N 9 N PORCH S 0 . YARMOUTH, MASS L 0 T 59 ` N o' SLAB KITCHEN ROOM DATE: MAY 31, 2015 0^ 2�1\ DTH #1 #40 FULL "DB -6" BATH FOUNDATION OWNER/APPLICANT:^� 26� �- BATH / O BED#1 G", / JEFFREY MARR ,•" _ \ / �Q 11 MARK LANE = LOT 6 — \ BED#3 BED#2 MILTON, MA 02186 14,870± S.F. 617-698-3333 24 _ \ RET. WALL / O SHEET 1 OF 2 \ -- 1 BENCHMARK Z CORNER OF BULKHEAD. / PREPARED BY: 80 7g,p6, srp ADC FENCe l EAS SURVEY, INC. �• �/ EXISTING LEACHING PIT & EXISTING 1,000 "] Q P.O. B 0 X 1729 "D" BOX TO BE PUMPED, GALLON SEPTIC ` ` CRUSHED AND ABANDONED TANK TO REMAIN SANDWICH, MA 02563 IN ACCORDANCE WITH 0 20 30 40 TITLE 5. PH. (508) 888-3619 Z CELL (508) 527-3600 L 0 T 57 GRAPHIC SCALE: acne Date EAS.SURVEY@YAHOO.COM 1 INCH = 20 FEET SILL ELEV. 30.67 GRADE ELEV. 28. ISA 4" PVC FULL '. SCH 40 FOUND. ��� INV.= 26.87 INV.= I III A muv- 25.86 10"TEE FINISH GRADE ELEV. 28.0 i 14"TEE I GAS BAFFLE 4'-1" . LIQUID LEVEL SE COVERS TO WITHIN 6" OF FINISH GRADE ELEV. 27.50 14'CS=0.05 4" PVC SCH 40 INV.= 25.66 DATUM: ° ° ° ° EXISTING 1,000 GAL TANK TO REMAIN VERTICAL DATUM: N.G.V.D. BENCH MARK USED: CORNER OF BULKHEAD CONSTRUCTION NOTES: ELEVATION 27.80 15-0108-SEP.DWG SITE & SEWAGE REPAIR PLAN #4D CA P T. BACON ROAD IN So. YARMOUTH, MASS DATE: MAY 31, 2015 OWNER/APPLICANT: JEFFREY MARR 11 MARK LANE MILTON, MA 02186 617-698-3333 SHEET 201F 2 PREPARED BY: EAS SURVEY, INC. P.O. BOX 1729 SANDWICH, MA 02563 PH. (508) 888-3619 CELL (508) 527-3600 EAS.SURVEY@YAHOO.COM 'H-10 DB6 D -BOX INV.= 24.96 OBSERVATION PORT TO GRADE / SCREW ON CAP ELEV. 27.50 GROUND ELEVATION 27.90 rno ri cv oc n 3' MAX COVER 6' CS= 0.02 (24) H-10 QUIK-4"s INFILTRATOR \INV,=24.67 4 ROWS OF 6 UNITS V.=24.79 EACH UNIT 34" x 48" x 12" 24.0' --� 11.33'x24.0' LEACHING AREA IN FIELD CONFIGURATION 1 ELEV. 19.0 ADJ. G.WATER TH#1 1. CONTRACTORS / INSTALLERS SHALL VERIFY GRADES AND ELEVATIONS AND SITE CONDITIONS PRIOR TO COMMENCING WORK ON THE SITE. 2. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 3. VEHICULAR TRAFFIC, PARKING OF VEHICLES AND PLACING MATERIALS OVER THE SEPTIC TANK IS PROHIBITED. GENERAL NOTES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE V AND THE TOWN OF YARMOUTH RULES AND REGULATIONS FOR SUBSURFACE DISPOSAL OF SEWERAGE. 2. AT LEAST ONE ACCESS POINT OVER TANK TEES SHALL BE ACCESSIBLE WITHIN 6" OF FINISH GRADE, WITH ANY REMAINING ACCESS PORTS BROUGHT TO WITHIN 12" OF FINISH GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 10' OF DRIVES OR PARKING AREAS THEY MUST WITHSTAND H-20 LOADING. 4. THE EXCAVATION CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTILITIES PRIOR TO ANY EXCAVATION. 5. ANY MASONRY UNITS USED TO BRING COVERS TO GRADE OR WITHIN 6" OF GRADE SHALL BE MORTARED IN PLACE. 6. FINISH GRADE SHALL HAVE A MINIMUM OF 0.02 FEET PER FOOT OVER THE S.A.S. AND DISTRIBUTION BOX. 7. SEPTIC TANK SANITARY TEE'S SHALL BE CONSTRUCTED OF SCHEDULE 40 PVC AND SHALL EXTEND A MINIMUM OF 6" ABOVE THE FLOW LINE AND SHALL BE ON THE CENTERLINE AND LOCATED DIRECTLY UNDER THE CLEAN OUT MANHOLES. 8. THE INLET PIPE INVERT ELEVATION SHALL BE NO LESS THAN 2 INCHES NOR MORE THAN 3 INCHES ABOVE THE INVERT ELEVATION OF THE OUTLET PIPE. 9. THE SEPTIC TANK SHALL HAVE A MINIMUM COVER OF 9 INCHES 10. THE OUTLET SANITARY TEE SHALL BE EQUIPPED WITH A GAS BAFFLE, 4 INCHES IN DIAMETER AND CONSTRUCTED OF 4" PVC 11. ALL PIPES SHALL BE SCHEDULE 40 PVC SEWER PIPE AND SHALL BE SLOPED 1/4 INCH PER FOOT MIN. EXCEPT FOR THE FIRST TWO FEET OUT OF THE DISTRIBUTION BOX WHICH SHALL BE LEVEL 12. CHANGES OR REVISIONS TO SEPTIC DESIGN REQUIRE NOTIFICATION TO EAS SURVEY INC. FOR B.O.H. AND DESIGN ENGINEERS REVIEW AND APPROVAL. 13. MAGNETIC TAPE OVER ALL COMPONENTS. N mL24.0 °' 00 ui L6 ac OBSERVATION PORT(S) / / SCREW CAPS i PA �--2.83'---+--2.83'---{-- 2.83'--+--- 2.83'--- { ------ 11.33' ---� a to nF n.. E VIEW N SYSTEM DESIGN PROPOSED DESIGN FLOW 3 BEDROOMS AT 110 GPB/D 3I2 GPD REQUIRED SEPTIC TANK 330 x 2__ _ ___660 GAL. EXISTING SEPTIC TANK = --100-Q_GAL. SIZE OF LEACHING FACILITY REQUIRED DESIGN PERC RATE _<_2 ____MIN./INCH LONG TERM APPL. RATE-2--LA-GPD/S.F. SIZE OF LEACHING SYSTEM PROVIDED: 330 _ 0.74 SF/GPD = 445 S.F. MIN. REQ. USING 24 QUIK-4 INFILTRATORS CHAMBERS NO STONE AROUND 4.73 SF / LF X (4 x 24) = 454 S.F 454 x 0.74 G/SF = 336 GPD 336 GPD PROV > 330 GPD REQ. = 6 GPD RES. NO (GARBAGE DISPOSAL / GRINDER ALLOWED) GROUNDWATER ADJUSTMENT DEPTH TO BOTTOM WELL MIW-29 WELL ZONE: B WELL DEPTH: 7.14 WELL ADJUSTMENT: 1.4 DEPTH OF WATER: 11.0' DEPTH OF ADJ.: 9.6 DTH #1 i' INDICATES DEEP TEST HOLE INDICATES P-1 64" PERC TEST NO MOTTLING NO WEEPING --10- 118" INDICATES ADJ. GROUNDWATER ==> 132" INDICATES OBS. GROUNDWATER VARIANCES REQUESTED NONE D.T.H. #1 0 DATE: 4/30/15 GROUND ELEV. 28.6 ADJ. GW 19.0 FILL 126" B LOAMY SAND 10YR 4/3 44" ELEV = 24.9 C MED./COARSE 64" SAND 10YR 6/6 ELEV.=19.0 1115" '132" ELEV = 17.6 B.O.H. AMY VON HONE SOIL EVALUATOR ED. STONE BACKHOE OPERATOR. ELLIS BROTHERS (KEVIN) SOIL TYPE:1_ PERC RATE: <2 MIN. PER INCH LOADING RATE: 0_74 GAL/SF/MIN