HomeMy WebLinkAboutEngineered Plan - Rev. 2015-- ACCESS COVER AT FIN. GRADE EL. 29 t �V-qTPAA PRn1=11 (NOT TO SCALE) PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVER TO WITHIN 6" OF FIN. GRADE MINIMUM 1' OF COVER 1 MINIMUM 75' OF COVER OVER POLY TANK OVER PRECAST !yam PROPOSED 1,500 GALLON POLYETHYLENE SEPTIC TANK (H-10) EL. 21 27.7 4"taSCH40 PVC EXIST. SPOT ELEV. -[99}-- PROPOSED CONTOUR 16.1 "(1.34') PROPOSED SPOT EL. TH1 PIPES LEVEL 1ST 2' TEST HOLE 26.37' PROP. CLEAN-OUT CQ) UTILITY POLE VyC FIRE HYDRANT GAS BAFFLE 10,ofol-, 0o05o WATERTEST D'BOX °°o00o(,o^o^oo FOR LEVELNESS 0 25.24' 25.07' 25.0' 6" CRUSHED STONE OR MECHANICAL " DEPTH OF FLOW = 4' COMPACTION. (15.2 [2]) NOTE. • 2 MIN. WALL THICKNESS REQUIRED REQUIRED TEE SIZES: INLET DEPTH = 10" MIN. BELOW FLOW LINE OUTLET DEPTH = 14" MIN. BELOW THE FLOW LINE ? NOTE. STANDARD TEES ARE TO BE USED. DO NOT USE MANUFACTURERS TEES THAT COME WITH THE TANK ( 2 % SLOPE) (L-5-% SLOPE) FOUNDATION 19' SEPTIC TANK 32' - *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEND- - 99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. -[99}-- PROPOSED CONTOUR 99 PROPOSED SPOT EL. TH1 TEST HOLE C.O. PROP. CLEAN-OUT CQ) UTILITY POLE VyC FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: PHIL RENAUD DATE: 5/27/15 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS o„ 4 FILL 9" ELEV. 28.0' B LS 13" 1 OYR 6/4 26.9' C PERC 0 52" MS 2.5Y 7/6 126" I 117.5' NO GROUNDWATER ENCOUNTERED 15-114 I i 1 SLOPE' I i ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. UIRED OVER SYSTEM 28.5' , /PROVIDE INSPECTION PORTS TO WITHIN 3" OF FINISH GRADE 3' } USE (16) H-20 HIGH CAPACITY INFILTRATORS IN CONFIGURATION SHOWN (NO STONE PROPOSED) (-1-7. SLOPE) 6.58' D' BOX g' LEACHING (LONGEST) (FACILITY BOTTOM TH 1 EL. 17.5' INSTALLER SHALL CONFIRM SUITABLE SOILS IN AREA OF LEACHING FACILITY PRIOR TO INSTALLATION OF ANY PORTION OF SYSTEM NOTE. SYSTEM IS DESIGNED TO AVOID REMOVAL OF SIGNIFICANT TREES AND PLANTINGS CONSULT WITH HOMEOWNER IF ANY REMOVAL EXPECTED. EXISTING STOCKADE FENCE (T1P.) Scale:1 "= 20' 0 10 20 30 40 50 FEET PROVIDE 20' OF 40 MIL LINER IN AREA SHOWN. TOP AT ELEV. 25.5 , BOTTOM AT ELEV. 21.5± NOTES 1. DATUM IS ASSUMED 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND LOCUS MAP VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD. UTILITIES PRIOR TO COMMENCEMENT OF WORK. NOT TO SCALE 11. ANY UNSUITABLE MATERIAL ENCOUNTERED ASSESSORS MAP 39 PARCEL 54 SHALL BE REMOVED 5' BENEATH AND AROUND THE SITE IS NOT WITHIN ZONE II PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED VARIANCE REQUESTED UNDER 15.405 1b: REDUC- AND REMOVED TION IN SETBACK SAS TO FNDN (BH), 20' TO 11' EXPECTED MACHINERY ACCESS (TIGHT). HYDRANGEA AND ARBOR EXPECTED REMOVALS CoQ �e 28.22___ DATE Permvalid for REPAIR of, SEI'"I-1C SYS"I'F:M11A ON V , tluc to State and Luca) septic variances. fRcard of ff.ealth review anis approval is rcyuired fqr ,,y future a(lditions%rcnuvation./alterations to sewage facilities and/or structures/d�%cmng. Yarmouth H;calth Department �l Date c I DANIEL A. OJALA, P.E., P.L.S. (40 MILLINER PROPOSED) SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED EXISTING 2 BEDROOM DWELLING DESIGN FLOW: 3 BEDROOMS ® 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL. H-10 POLY SEPTIC TANK LEACHING: 4.73 SF/LF x 6.25' LENGTH = 29.56 SF PER HIGH CAPACITY INFILTRATOR UNIT 330 GPD/0.74 GPD/SF = 445.9 SF LEACHING REQ'D 445.9 SF/29.56 SF/UNIT = 15.1 UNITS THEREFORE, USE GRAVELLESS SYSTEM OF (16) H-20 HIGH CAPACITY UNITS IN FIELD CONFIGURATION SHOWN 16 UNITS x 29.5 SF = 472 SF > 445.9 SF 472 SF (0.74) = 349 GPD (OK) PROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 25 VACATION LANE WEST YARMOUTH PREPARED FOR ADITI JOSHI JUNE 1, 2015 JUNE 26, 2015 (HEALTH COMMENTS) off 508-362-4541 I fax 508-362-9880 downcope.com 0 40WJ7 cape ea,giaeefing, inc. civil engineers land surveyors 939 Main Street ( R to 6A) YARMOUTHPORT MA 02675 , MA