Loading...
HomeMy WebLinkAboutEngineered Plan - Rev. 2006EaVCHUAHK. TOP_ OF FOUNDATION. ELEV. 100.00_ 10 FT. MINIMUM (ASSUMED) 2,00 4 CAST IRON PIPE (OR EQUAL) MINIMUM PITCH 1/4" PER FT. ELEV, - 98.00 _ ELEV. _ _27,25 LIQUID OUTLET DEPTH TEE 4 FEET 14 INCHES 5 FEET 19 INCHES 6 FEET 24 INCHES 7 FEET 29 INCHES 8 FEET 34 INCHES LEGEND: 11 EXISTING SPOT ELEVATION 00X0 EXISTING CONTOUR----00---- COLOR FINAL SPOT ELEVATION 00.0 FINAL CONTOUR 00 SOIL TEST LOCATION 10YR6/1 UTILITY POLE -0- ROOTS TOWN WATER=W W CATCH BASIN �® j 10YR6/6 GAS LINE -OG ` ROOTS CESSPOOL C.P. C1 CLEANOUT 0. 20 FT. MINIMUM FROM CELLAR. 10 FT. MINIMUM'FROM SLAB OR CRAWL SPACE CLEAN SAND CONCRETE AL.SPECTION PORT] COVERS 4" SCHEDULE 40 PVC PIPE D SEED MIN. PITCH 1/8" PER FT. ° LAYER OF , - TO 1/2" 00.10 MAX.�+SHED STONE VENT m 6" MAX. 7.85 MIN. NOT REQUIRED FLOW LINE _TMION. ELEV. _ _97•� LEVEL GAS ELEV. = 96.92 6" SUMP ELEV. _ _98.75_ BAFFLE DISTRIBUTION ELEV. _ (TO BE PLACED ON FIRM BASE) BOX TO BE WATER TESTED 1500 GALLON IF MORE THAN ONE OUTLET SEPTIC TANK (TO BE PLACED ON FIRM BASE) 3/4" TO 1 1/2" CLEAN -� DOUBLE WASHED STONE FREE OF FINES & SILT SEWAGE DISPOSAL SYSTEM PROFILE NOT TO SCALE ■ 98.2 0 0 :'o 0 1*1 ELEV. = 95.77 / 12 HIGH CAPAC/TY lNF/L TRA TORS WITH STONE _z IN A 24 X 25',V 10"FIELD FORMATION :2•07 SOIL ABSORPTION LO WELL MIW 29 ZONE A SYSTEM (SAS) I INDEX 8.2 10/05) ADJUST 1.7 USGS PROBABLE WATER TABLE ELEV. = -=7-Q- OBSERVED WATER TABLE (11/16/05) ELEV. = BOTTOM OF TEST (HOLE ELEV. = 87.0.0_ f i SOIL TEST 1500 GALLON SEPTIC TANK : 98.9. X59. <11 \ GR �0 6� P 99. G 4 ��V� 9.4 sy� �G 0�5 99� <<Q �o \ 0.00���� I 98.9 99.3 G P 98.9 • 9.3 L 0 T 5,979 f S.F. AQP 99.0 GRP y0' •9 VV\ J X, OF kAT ti T A. DUMASN NO# ASTER � S�INITAR��`N EVIL ; J C11 DATE OF SOIL TEST Uff-M j .2-0 5 J. $OIL TEST DONE 13Y SWEETSER'ENrINEERING WITNESSED BY _A VO 1iQ9 OBSOVAIION H= 1 ELEV, =.,._99.00 PERCOLATION RATE 4 2- MIN./INCH AT 51 INCHES DEPTH HORIZ TEXTURE COLOR MOTT. OTHER 0-4 A/E MEDIUM SAND 10YR6/1 NO ROOTS 4-20 B LOAMY SAND 10YR6/6 ROOTS 20-36 C1 MEDIUM SAND 2.5Y7/4 36-144 C2 FINE SAND 2.5Y7/1 l� WATER ENCOUNTERED AT 120"_ ELEV. _ __82. 012 DESIGN CALCULATIONS NUMBER OF BEDROOMS4 GARBAGE DISPOSAL UNIT TOTAL ESTIMATED FLOW ( 110 GAL/BR./DAY X 4 BR.) _444_ GAL./DAY REQUIRED SEPTIC TANK CAPACITY _B$4_ GAL. ACTUAL SIZE OF SEPTIC TANK 1500 GAL. SOIL CLASSIFICATION __I__ DESIGN PERCOLATION RATE Ste`__ MIN./IN. EFFLUENT LOADING RATE Dj_f GAL./DAY/S.F. LEACHING AREA 6.00 SQ. FT. 24 X 25 LEACHING CAPACITY (AREA X RATE) 444.00 GAL./DAY 600.00 X 0.74 RESERVE LEACHING CAPACITY NQNE GAL./DAY NOTES:. 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE 5 AND THE TOWN'S RULES AND REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE. 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO WITHIN 6" OF FINISHED GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. 4. ANY MASONRY UNITS USED TO BRING COVERS TO GRADE SHALL BE MORTARED IN PLACE. 5. NO DETERMINATION PAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 6. UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR IS TO CALL "DIG -SAFE" AT 1-888-344-7233 AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE. 7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION. IS TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER IMMEDIATELY. 8. PARCEL IS IN FLOOD ZONE __C 9. LOT IS SHOWN ON ASSESSORS MAP 22 AS PARCEL 339 Yarmouth Health Department APPROVED 62 pie ID2te APPROVED: BOARD OF HEALTH DATE AGENT C.•\S8\PROJ,6291-00�dwg\6291-sos1.DWG 02005 SWEETSER ENGINEERING PINE STREET Ofr,Wallk -� IN ST FRANKLa SUMMER ST. a can WATER ST. C-� y PEARL Sr o BROADWAY gP. a � a a ^ LO PROPOSED SEPTIC DESIGN FOR SCOTT FEEN Loc* LOT 159 139 LET11S ROAD TEST YARMOUTH, MASS S ' 1SER E.hULNEEMG 235 GREAT WESTERN ROAD 0. BOX 713 39808922 SOUTH DENNIS, MASS. 02660 DATEN OV. 16, 2005 ALE 1 " = 20' PC REV. MAY 4, 20067(roe No. 6291-00 11 LOCATION MAP REV. SHEET 1 OF 1 C.•\S8\PROJ,6291-00�dwg\6291-sos1.DWG 02005 SWEETSER ENGINEERING