Loading...
HomeMy WebLinkAboutEngineered Plans - 2015lr - — 98 — — EXISTING CONTOUR 98 PROPOSED CONTOUR x 100.98 EXISTING SPOT GRADE W EXISTING WATER SERVICE %� -- EXISTING GAS SERVICE U UNDERGROUND WIRES —� H. Wb`.-- OVERHEAD WIRES Cn TEST PIT x DECK ,57 x BENCHMARK LEGEND 10� EXISTING CESSPOOL GARAGE DECK DEN I KIT./DIN. I BATH FLOOR PLAN S 34' 14'40" W - \ fence line 100.05' \` x 100.75 LOT 5 14,930 ±SF \, MBLU 115-140 i x 100.86 XV r x 98.3 � x 7.46 LO --1 4. ' TP 13' 97.7 U) TO BE PUMPED, FILLED WITH \ n t� U SAND & ABANDONED, OR REMOVED \ a N ® N 7� 0 i G Po°c �S moo` LOCUS ore o� 5e I LOCUS MAP NOT TO SCALE 97.02 PROPOSED SEPTIC TANK % 10�i.84I D100.40 I 4 } x BENCHMARK COR./BULKHEAD -- 9.10 -O - O - EL.=99.19 W 103,22 +96.61 cv Z up 101.82 100,53 o x Cn x DECK ,57 x o o S2 o k - cn U)I + 103,02 GARAGES /EXIST. SEWER INV.=96.85 IEXIS77NG / �io1.32 x 1H 17) WA 0 T.O,F. =100.941 + 99.E 100.68 / . 102.6'4 !!00.30 I �- 100.68 x o Q, -I- 100.75 WALK � j ON C 101,35 ,:. CHS IL • 99.99 I 99 67 x 99.41 G 98 102. .:.' Q: °.. LAMP 9.41 / 99,92 — 100.00' x 9811-6 + , 5 • N._,..��" — F fence line L10,00 98.27 98.07 97.82 EDGE OF PAVEMENT 97.26fij STARBUC'K LANE D ZU Z /4x .0 o y� PETER T. McENTEE PROPOSED SEPTIC SYSTEM UPGRADE PLAN CIVIL No. 35109 78 STARBUCK LANE, YARMOUTHPORT, MA A £G/SZE - Prepared for: Mark Mahon, 78 Starbuck Lane, Yarmouthport, MA 02675 5/ Engineering by: Survey review by: SCALE DRAWN JOB. NO. OWNER RECORD Engineering Works, Inc. JC Engineering, Inc. 1"=20' P.T.M. 146-15 MARK MAHON 12 West Crossfield Road 2854 Cranberry Hwy. 78 STARBUCK LANE Forestdale, MA 02644 E.Warehom, MA 02538 DATE CHECKED SHEET NO. YARMOUTHPORT, MA 02675 (508) 477-5313 (508) 273-0377 5/21/15 P.T.M. 1 Of 2 NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL.=96.1 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. SEPTIC TANK PROPOSED S.A.S. INSTALL RISERS & COVERS OVER INLET & PROPOSED D-BOX INSTALL 1 INSPECTION PORT(MIN.) OUTLET AND SET TO 6" OF FINISH GRADE INSTALL RISER & WATERTIGHT AT END OF S.A.S. T.O.F.=100.94± COVER SET TO 6" OF GRADE F.G. EL.=99.5± F.G. EL.=98.3± EXISTING F.G. EL -98.2± F.G. EL.=98.i± MAINTAIN 2% GRADE (MIN.) OVER S.A.S. L = 17' 0 S=1% (MIN.) L = 2' F7 L = g' INSPECTION PORT 4"SCH40 PVC TOP OF TANK=96.77 S=1% (MIN.) ®S=1% (MIN.) ONE (MIN.) TOP 4"SCH40 PVC 4"SCH40 PVC 3" o 10" _ - 44" LIQUID LEVEL 14" 6 7.13" TO ADD INVERT cAs� INV.=95.85 BOTT. OF TANK PROPOSED INV.=95.68 5 ROWS OF 4 UNITS AT 5.0' UNIT / ) = 20.0' =92.23 INV.=95.90 PROPOSED 1500 GALLON SEPTIC TANK INFILTRATOR IM1530 GALLON PLASTIC TANK D-BOX SOIL ABSORPTION SYSTEM (PROFILE) INV.=95.60 INV.=96.15 ESTABLISH VEGETATIVE COVER ICONNECT TO NEW SEWER BACKFILL WITH CLEAN NATIVE OR AT HOUSE, INV.=96.85 PERC SAND TO TOP OF CHAMBERS NOTES: BREAKOUT=TOP TOP ELEV.=96.08 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INV. ELEV.=95.60 INVERTS, PRIOR TO INSTALLATION. BOTTOM ELEV.=95.00-� 2) SEPTIC TANK & D-BOX SHALL BE SET LEVEL AND 2.83' TRUE TO GRADE ON A MECHANICALLY COMPACTED 5' MIN. ABOVE BOTTOM OF SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN T.P. EXCAVATION OR G.W. EFFECTIVE WIDTH=14.2' 310 CMR 15-221(2). 3) INSTALL INLET & OUTLET TEES AS REQUIRED. EXISTING SUITABLE ADJUSTED G.W., EL=88.1 - MATERIAL 4) GAS BAFFLE TO BE INSTALLED ON OUTLET TEE _ AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. USE 5 ROWS OF 4-ADS Arc 36 UNITS WITH NO 5) SEPTIC TANK SHOULD NEVER BE EMPTY AT TIMES STONE AND NO SEPARATION BETWEEN EACH ROW OF ANTICIPATED FLOODING. SEPTIC SYSTEM PROFILE TYPICAL SECTION N.T.S. SOIL LOG GENERAL NOTES: DATE: MAY 13, 2015 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF SOIL EVALUATOR: PETER McENTEE PE(SE#1542) HEALTH AND THE DESIGN ENGINEER. WITNESS: AMY VON HONE R.S. HEALTH AGENT 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE ELEV. TP DEPTH LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR 97.7 A 011 TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE-- LOAMY SAND -- - DESIGN ENGINEER. 10YR 4/1 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING 97.0 8" FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN B ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. LOAMY SAND 1OYR 5/8 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 95.7 24" 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. C PERC 8. THERE ARE NO WELLS WITHIN 150' OF THE PROPOSED S.A.S. 18"/36" 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS MED. SAND AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE 2.5Y 6/4 DIRECTED BY THE APPROVING AUTHORITIES. 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 88.1 ADJ. G.W. - 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS 85.7 STG. G.W. 144" 1N THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND - - REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). STANDING G.W. AT EL.=85.7, INDEX WELL Al W-247, ZONE C 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE WATER LEVEL=22-5 (APR2015), ADJUSTMENT=2.4', ESTIMATED HIGH G.W., EL.=88.1 INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL. PERC RATE 2 MIN/IN. ("B/C" HORIZONS) 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND NOT CONSIDERED TO BE A PROPERTY LINE SURVEY. 63.5" 14. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED SEPTIC SYSTEM COMPONENTS NOT SHOWN ON THE PLAN 13" 33.8" TOP VIEW DESIGN CRITERIA NUMBER OF BEDROOMS: 2 BEDROOMS SOIL TEXTURAL CLASS: CLASS 1 60" DESIGN PERCOLATION RATE: <2 MIN IN / END CAP END CAP FRONT VIEW SIDE VIEW 6id DAILY FLOW: 220 GPD END CAP DESIGN FLOW: 330 GPD REAR/TOP VIEW GARBAGE GRINDER: NO NOTE: UNIT CONFIGURATION AND AVAILABILITY SUBJECT SIDE VIEW TO CHANGE WITHOUT NOTICE. PRODUCT DETAIL MAY LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF DIFFER SLIGHTLY FROM ACTUAL PRODUCT APPEARANCE .74 GPD/SF 4640 TRUEMAN BLVD PROPOSED SEPTIC TANK: GALLON CAPACITY HILLIARD, OHIO 43026 Are 36 DETAIL " INFILTRATORRIM IM1530 GALLON PLASTIC TANK ADVANCED o �E . INC. UNITS MUST BE STAMPED HD PROPOSED SEPTIC SYSTEM UPGRADE PLAN PROPOSED D-BOX: 1 INLET, 5 OUTLET (MINIMUM), H-20 RATED USE 5 ROWS OF 4-ADS Arc 36HD UNITS WITH No 78 STARBUCK LANE, YARMOUTHPORT, MA STONE AND NO SEPARATION BETWEEN EACH ROW Prepared for: Mark Mahon, 78 Starbuck Lane, Yarmouthport, MA 02675 BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.80 SF/LF OF UNIT) Engineering by: Survey review by: SCALE DRAWN JOB. NO. (Arc36 Units) 20 UNITS x 5.0 LF x 4.80 SF/LF = 480-0 SF TOTAL AREA = 480.0 SF Engineering Works, Inc. JC Engineering Inc. N.T.S. P.T.M. 146-15 12 West Crossfield Road 2854 Cranberry Hwy. DATE CHECKED SHEET NO. DESIGN FLOW PROVIDED: 0.74 GPD/SF(480.0 SF) = 355.2 GPD Forestdale, MA 02644 E.Wareham, MA 02538 (508) 477-5313 (508) 273-0377 5/21/15 P.T.M. 2 Of 2