Loading...
HomeMy WebLinkAboutEngineered Plan - 2015FOU SYSTEMPROFILE ( o SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2" PEASTONE OR GEOTEXTILE 23.8' FILTER FABRIC OVER STONE F�[ -_ �723.75' OF COVER OVER PRECAST ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCREIL TO WITHIN 3" GRADE 2% SLOPE) REQUIRED OVER SYSTEM BLOCKS OR PRECAST H-10 NOTE: MIN. WALL THICKNESS 2" PRECAST RISERS RISERS (TYP.) 4"q,SCH40 PVC MORTAR ALL 2'0 COMPONENTS INVERT IN 20.25' PIPES LEVEL 1ST 2' 4' �1 (TYP ) ENDS SIDES 21.08' * 1500 GAL H-10 po�o�o�o�; ..... ..... .: r :. ...... gog00000 10" TEE ®��0 ®®�C'] ®®®®-®® ° 20,87' TEE SEPTIC TANK 20.62 0 0 0 0 0 0 6" MIN. SUMP °°°°O°0°°°O° )�O�O�O�O ®®®®®®®I�®®® �p0o.. OpO GAS BAFFLE +°00000°0°,0° 12" MIN. INT. 'DIM. ci ,°oo°000° ®®®®®®®®®®® a®®®®®®®®®® 00000000 °°°°° 18.25 0000000a , °o°o°o°o +: 4' LIQ. LEVEL (ACME OR EQUAL) j 20.52' 20.35 ...... ... •... WATERTEST D'BOX I FOR LEVELNESS c00o0°0000000°0000000o0o0o0000000000a0000000o H-10 500 L. LEACHING CHAMBERS BY ACME PRECAST OR EQUAL 0°o°,o°000000 0,0,000000000°0r0�00000 0000000. 3/4"-1-1/2" DOUBLE WASHED STONE 4MIN. ffI (2) UNITS REQUIRED ALL AROUND PRECAST STRUCTURES 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 25.00' X 12.83' COMPACTION. (15.221 [2]) J a (2.5 % SLOPE) (-L-% SLOPE) ( 1 % SLOPE) t MIN. LEACHING ADJUSTED GROUNDWATER FOUNDATION- 13' SEPTIC TANK 10 D BOX 12 FACILITY j' EL. 14.25 I i *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS t PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM a j LEGEND- - 99- EXISTING CONTOUR X 991 EXIST. SPOT ELEV. -[99]- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 12' 0 TEST HOLE 2-7- SLOPE OF GROUND UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST- HOLE LOGS ENGINEER. DANIEL E. GONSALVES, SE #13587 Z. WITNESS: AMY VON HONE, RS DATE: -5/20/15 CD PERC. RATE _ < 2 MIN/INCH 12' 0o CLASS I SOILS ELEV. 4 0" 22.7' A G -W ADJ. DATA: WELL: AIW 230 LS ZONE: B 1OYR 4/2 ADJ: 0.3' (APRIL) 6" E MS 10" 2.5Y 4/1 21.9' B LS 30" 1 OYR 5/6 20.2' C PERC MS 2.5Y 7/3 126" 1 112.2' GROUNDWATER ENCOUNTERED AT 105" EL. 13.95 LICE # 15-09' BENCH MARK - CORNER OF FLAGSTONE PATIO. EL. = 22.8 s3LOT 31 12,000± S.F. 22.62 120 ()0 �'7.78 7 ----q 22.60 74 FLAG W PATIO I 2.86 .77 2.9 .60 FLAG I PATIO 122.88 4 1 23.23 x 22.77 "�� � r7 DE N GRAVEL AREA P&A NOTES 1. DATUM IS ASSUMED 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 21.49 1 1 1 1 1 1 1 � 21.73 Vill s�q 22.9 V DR��Emk 23.3? F`�IED 1 22.94 1 EXIST. DWELL. TOP FNDN. EL. 23.8' x 23. tr I Ix 23.42 18 OA 120.0 1 W 23.28 CII0 1 22.07 \ o _ - - 22.97 OVER HEAD UTILS. \\ * 22.78 LOCUS MAP NOT TO SCALE ASSESSORS MAP 78 PARCEL 105 VARIANCES REQUESTED: UNDER MAX. FEASIBLE COMPLIANCE 15.405: (1h): REDUCTION IN SEPARATION TO G -W, 5' TO 4' SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS 4 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (25 + 12.83) 2 (:74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL: 472 S.F. 349 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND MA APPROVED DATE BOARD OF HLALIH TITLE 5 SITE PLAN OF 76 CAPTAIN BACON ROAD SOUTH YARMOUTH, MA PREPARED FOR Permit valid for REPAIR OF SEPTIC. S1S'rEM �tAOF&WfAEDWARD PEHHHA Jr. 2 ONLY, due to State and Local septic variances. .-t. F4fq'ggc Board of licaith review antlapproval is required for ti �� DANIEL o �N �o� any fuhrre additions/r'enus rtionslaIterations to DANIELA. �� OJALA � a A. DATE: MAY 28, 2015 � sewage facilities anti/or structures/dwelling. CIVIL 0 OJALA m No. 46502 � No. 40980 off 508-362-4541 I' Yarmouth Health Ucpartment o �� �o �� fax 508-362-9880 APPROVED/ °SFS G/STE �G,�`` �gNOSSSv�y�� I downcope.Com / G��� S/ONAL E SUR i d®Wn cape 0#7 ftee47gi , nc. A) Cil V civil engineers Dare land surveyors Scale:1 "= 20' �'�- ( f 939 Main Street (Rto 6A DATE DANIEL A. OJALA, P.E., P.L.S. YARMOUTHPORT MA 02675 0 10 20 30 40 50 FEET 15-091 PEREIRA.DWG 22•$� 6 CD 23.4 0 12' 0o CHERRY P&A NOTES 1. DATUM IS ASSUMED 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 21.49 1 1 1 1 1 1 1 � 21.73 Vill s�q 22.9 V DR��Emk 23.3? F`�IED 1 22.94 1 EXIST. DWELL. TOP FNDN. EL. 23.8' x 23. tr I Ix 23.42 18 OA 120.0 1 W 23.28 CII0 1 22.07 \ o _ - - 22.97 OVER HEAD UTILS. \\ * 22.78 LOCUS MAP NOT TO SCALE ASSESSORS MAP 78 PARCEL 105 VARIANCES REQUESTED: UNDER MAX. FEASIBLE COMPLIANCE 15.405: (1h): REDUCTION IN SEPARATION TO G -W, 5' TO 4' SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS 4 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (25 + 12.83) 2 (:74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL: 472 S.F. 349 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND MA APPROVED DATE BOARD OF HLALIH TITLE 5 SITE PLAN OF 76 CAPTAIN BACON ROAD SOUTH YARMOUTH, MA PREPARED FOR Permit valid for REPAIR OF SEPTIC. S1S'rEM �tAOF&WfAEDWARD PEHHHA Jr. 2 ONLY, due to State and Local septic variances. .-t. F4fq'ggc Board of licaith review antlapproval is required for ti �� DANIEL o �N �o� any fuhrre additions/r'enus rtionslaIterations to DANIELA. �� OJALA � a A. DATE: MAY 28, 2015 � sewage facilities anti/or structures/dwelling. CIVIL 0 OJALA m No. 46502 � No. 40980 off 508-362-4541 I' Yarmouth Health Ucpartment o �� �o �� fax 508-362-9880 APPROVED/ °SFS G/STE �G,�`` �gNOSSSv�y�� I downcope.Com / G��� S/ONAL E SUR i d®Wn cape 0#7 ftee47gi , nc. A) Cil V civil engineers Dare land surveyors Scale:1 "= 20' �'�- ( f 939 Main Street (Rto 6A DATE DANIEL A. OJALA, P.E., P.L.S. YARMOUTHPORT MA 02675 0 10 20 30 40 50 FEET 15-091 PEREIRA.DWG