HomeMy WebLinkAboutEngineered Plans - 20151 PB 26,P05 EXISTING CESSPOOLS TO BE REMO QED (SEE NOTE 11) PROPOSED SEPTIC TAN 1500 GALLON CAPACITY LOT 291 99,39 OWNER OF RECORD RECORD UTLEY, MICHAEL P 110 BAYVIEW STREET WEST YARMOUTH, MA 02673 102.64 101,99 U k a 0 0 LOT 288 1 LOT 287 1 ABUT, GARAGE Permit valid for REPAIR OF SEPTIC SYS11M ONLY; clue to State and Local Sehtic variances. Board of Health review and alfl!roval iS required for any, future .90(litions/rentiv:itions/alterations to sewage facilities.and/or structures/dwelling. Yarmouth Ilivalth l)eha1-t1nc11t APPSO VE_D/; / x -53, '' fi 101,82 HED 102,09s� o x CONTOUR rX f�s2'_—20�--I---�10' 10 1 40 MIL POLY LINER TOP EL.=99.5 p --I N O E WATER SERVICE I --I` -1 I BOTT. EL.=96.0 10 0 -4- -I -= -I S S. '- OVERHEAD WIRES ~1 enchmark Set BM P OF SONO TUBE ' I IEL. 1) An 8' variance, S.A.S. to cellar wall (entry), for a 12' setback. =101.19 101 3 X— 101154 I _ sh BALC. J EX• SEWER 1 INV.=10Q.bf '92 ABUT. HOUSE EXISTING _ HOUSE(#110)/ m I TOF=102.2E Q) I ' a 8`LOT ,.. 289 F. �... 100.6 -2100,63 - a ' . .00 LOT X290 o G . -42 40 SF 53.00' 98,42 edge of povement BAYVIEW Pg 0.00 97.82 97.44 97.22 STREET 10 0 F MAss9c�o o PETER T. McENTEE o CIVIL No. 35109 --99--EXISTING CONTOUR x 100.98 EXISTING SPOT GRADE —W—EXISTING WATER SERVICE —G—EXISTING GAS SERVICE OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE OVERHEAD WIRES Albo— in t TEST PIT —310 CMR 15.405(1)(b): CONTENTS OF LOCAL UPGRADE APPROVAL BENCHMARK 1) An 8' variance, S.A.S. to cellar wall (entry), for a 12' setback. LEGEND GENERAL NOTES: Rosetta St BOARD OF HEALTH AND THE DESIGN ENGINEER. q� 2• ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS N� OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE Lacu$ Albo— in t —310 CMR 15.405(1)(b): CONTENTS OF LOCAL UPGRADE APPROVAL 1) An 8' variance, S.A.S. to cellar wall (entry), for a 12' setback. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR a v TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. o 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN m ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 0 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE 0 Lewl5 Q HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. tLng o 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S. CJ >� e sed St AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE a�2 Railway Bluffs Rd Som Z Bay THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING Pork t CONSTRUCTION. Windmill St 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS LOCUS MAP REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2• ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS EXCEPT AS REQUESTED BELOW: —310 CMR 15.405(1)(b): CONTENTS OF LOCAL UPGRADE APPROVAL 1) An 8' variance, S.A.S. to cellar wall (entry), for a 12' setback. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE 0 THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF un HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. tLng 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S. CJ >� 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS U�nr AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE a�2 DIRECTED BY THE APPROVING AUTHORITIES. 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERT THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY. 14. THE ENGINEERING IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED SEPTIC SYSTEM COMPONENTS NOT SHOWN ON THE PLAN. MAP ID: 28-79 PROPOSED SEPTIC SYSTEM UPGRADE PLAN 110 BAYVIEW STREET, WEST YARMOUTH, MA Prepared for: Capewide Enterprises, 153 Commercial St, Mashpee, MA Engineering by: Surveying by: SCALE DRAWN JOB. N0. Engineering Works, Inc. KEngineering, Inc. 1 "=20' P.T.M. 173-15 12 West Crossfield Road 2854 Cranberry Hwy. DATE CHECKED SHEET N0. Forestdole, MA 02644 E.Worehom, MA 02538 (508) 477-5313 (508) 273-0377 7/2/15 P.T.M. 1 Of 2 NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL:99.1 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. SEPTIC TANK INSTALL RISERS & COVERS OVER INLET & PROPOSED D -BOX PROPOSED S.A.S. OUTLET AND SET TO 6" OF FINISH GRADE INSTALL RISER & COVER INSTALL 1 INSPECTION PORT(MIN.) T.O.F.=102.2± SET TO 6" OF GRADE AT END OF S.A.S. F.G. EL. =101.8± SHED 25.9' F.G. EL.=101.2± F.G. EL.=101.7± F.G. EL.=101.8± I---20� fff MAINTAIN 2% GRADE (MIN.) OVER S.A.S. PROPOSED }�IT �Q L - 13' L = 5' L - 8' INSPECTION PORT ONE (MIN.) ( N ^ ( to � '� S•A•S. �� ® S=1% (MIN.) ®S=1% (MIN.) PVC 0 S=1% (MIN.) 4"SCH40 4"SCH40 PVC 4"SCH40 PVC ���� � 10 t 6" •� 14" 7.13 TO � ��`' 6' O INV.=99.15 48" LIQUID INV.=98.90 INVERT �O LEVEL GAS BAFFLE IN' 98.85 INV.=98.68 r 5 ROWS OF 4 UNITS AT 5.0'/UNIT) = 20.0' Shr. BALC. PROPOSED D -BOX Ex., SEWER am AIRM AM AIM AM& INV.=98.60 SOIL ABSORPTION SYSTEM (PROFILE) lNI=Ibo. bt PROPOSED SEPTIC TANK ESTABLISH VEGETATIVE COVER ,EXISTING / r CONTRACTOR SHALL CONNECT TO EXISTING BACKFILL WITH CLEAN NATIVE OR Y HOUSE 10 1, SUITABLE 4" C.I. OR SCH 40 PVC SEWER PERC SAND TO TOP OF CHAMBERS V AT, OR ABOVE, INV. EL.=99.4 / TOF= 102..t o / BREAKOUT=TOP TOP ELEV.=99.08 NOTES: INV. ELEV.=98.60 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS, PRIOR TO INSTALLATION. BOTTOM ELEV.=98.00- 2) SEPTIC TANK & D -BOX SHALL BE SET LEVEL &2.83' 5' MIN. ABOVE BOTTOM OF TRUE TO GRADE ON A MECHANICALLY COMPACTED T.P. EXCAVATION OR G.W. EFFECTIVE WIDTH=14.2' 6" CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2). EXISTING SUITABLE S.A.S. LAYOUT 3) INSTALL INLET & OUTLET TEES AS REQUIRED. NO G.W., EL=90.6 r MATERIAL 4) CONTRACTOR SHALL INSTALL A GAS BAFFLE ON USE 5 ROWS OF 4 -ADS Arc 36 UNITS WITH NO 63.5" THE OUTLET TEE. STONE AND NO SEPARATION BETWEEN EACH ROW SEPTIC SYSTEM PROFILE TYPICAL SECTION 13" SOIL LOG 33,8" DATE: JULY 2, 2015 DESIGN CRITERIA SOIL EVALUATOR: PETER McENTEE PE(SE#1542) tam H: WITNESS: AMY VON HONE R.S. HEALTH AGENT TOP VIEW NUMBER OF BEDROOMS; 3 BEDROOMS TP ELEV. DEPTH 60" SOIL TEXTURAL CLASS: CLASS I 11 0 DESIGN PERCOLATION RATE: <2 MIN/IN 101.6 A AP CAP END VIEW FRONT VIEW SIDE LOAMY SAND END CAP DAILY FLOW: 330 GPD 10YR 4/2 REAR/TOP VIEW DESIGN FLOW: 330 GPD 100.6 12„ BLOAMY GARBAGE GRINDER: NO SAND NOTE: UNIT CONFIGURATION AND AVAILABILITY SUBJECT SIDE VIEW TO CHANGE WITHOUT NOTICE, PRODUCT DETAIL MAY LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF 10YR 5 8 98.6 36" DIFFER SLIGHTLY FROM ACTUAL PRODUCT APPEARANCE. .74 GPD/SF C1 PERC VD HLLARD, OHIO 40 TRUEMAN 3026 Are DETAIL ak PROPOSED SEPTIC TANK: 1500 GALLON CAPACITY M -C SAND 26"/42>, 2.5Y 6/4 Aovnrvceo owvNnce sYsreMs, INC, UNITS MUST BE STAMPED HD ST PROPOSED SEPTIC SYSTEM UPGRADE PLAN PROPOSED D -BOX: 1 INLET, 5 OUTLET (MINIMUM), H-20 RATED 92.6 108" USE 5 ROWS OF 4 -ADS Arc 36HD UNITS WITH NO C2 110 BAYVIEW STREET, WEST YARMOUTH, MA STONE AND NO SEPARATION BETWEEN EACH ROW FINE SAND Prepared for: Capewide Enterprises, 153 Commercial St, Mashpee, MA BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.80 SF/LF OF UNIT) 2.5Y 7/3 Engineering by: Surveying by: SCALE DRAWN JOB. N0. (Arc36 Units) 20 UNITS x 5.0 LF x 4.80 SF/LF = 480.0 SF Engineering Works, Inc. JC Engineering, Inc. NTS P.T.M. 173-15 TOTAL AREA = 480.0 SF 90.6 132" 12 West Crossfield Road 2854 Cranberry Hwy. NO GROUNDWATER ENCOUNTERED Forestdale, MA 02644 E.Wareham, MA 02538 DATE CHECKED SHEET N0. DESIGN FLOW PROVIDED: 0.74 GPD/SF(480.0 SF) = 355.2 GPD PERC RATE <2MIN./INCH ("C" HORIZONS) (508) 477-5313 (508) 273-0377 7/2/15 P.T.M. 2 Of 2