HomeMy WebLinkAboutEngineered Plan - Rev. 2014SYSTEM PROFILE (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE 22.0' MINIMUM .75' OF COVER OVER PRFCAST ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CRETE COVERS TO WITHIN 3" GRADE 27. SLOPE REQUIRED OVER SYSTEM PRECAST H-10 RISERS (TYP.) 2'0 4"OSCH40 PVC PIPES LEVEL 1ST 2' 4' CO ENDS 10" 1500 GAL H-10 14" 1-M;o�o 19.62' ° ° C]�0�.. O C7�C TEE SEPTIC TANK TEE o 0 0 o C7� C 19.37 o°o°0o0o0o0o °°°°°° > °O°O°O°�°10000000GAS BAFFLE 4 'o°o°o°o°°°i°0°°°0100000000 18.90' 18.73' 4' LIQ. LEVEL (ACME OR EQUAL10 : C�aC77 C�oC77 COoC07] OCaC0]] ��a��o��oC7 C�oCC7]] a�®C] CC�CC °°°°°°°°°°°°°°°°0000°°°°0000°°° °°°°°o°o°°°° Lc00on2l?q 0°0o0°0o0�q�o�gg00000o0. 3/4"-1-1/2" DOUBLE WASH-10 500 HED STONE 4' MIN. ALL AROUND PRECAST STRUCTURES 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 25.0' X 12.83' COMPACTION. (15.221 [2]) WATER -TEST D'BOX FOR LEVELNESS (1__% SLOPE) ( 1 +! SLOPE) (-1-7. SLOPE) FOUNDATION 19' SEPTIC TANK 40' D' BOX 12' LEACHING FACILITY *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEND- - 99- EXISTING CONTOUR X 99-' EXIST. SPOT ELEV. 99 PROPOSED CONTOUR 9 9-1 PROPOSED SPOT EL. TH 1 FRONT SETBACK 30' TEST HOLE 2� SLOPE OF GROUND MIN. UTILITY POLE 20' FIRE HYDRANT NOTE NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE WITNESS: PHIL RENAUD (BoH) DATE: 10/16 /13 PERC. RATE _ < 2 MIN/INCH CLASS 1 SOILS IN 10" '4 A LS 1OYR 4/2 ELEV. 21.6' 0" B LS 2511 1OYR 6/8 19.5' PERC C MS 1OYR 7/4 132" ,3-258 110.6' 120" NO GROUNDWATER ENCOUNTERED NOTE: GARAGE FOOTINGS TO BE PLACED ON NATURAL SOIL (NOT FILL) ELEV. HIGH PT. 21.69 x21.19 i 21 Fn-, i \ x 21.85 Fo \ �F A\ x; Scale: 1 "= 20' 0 10 20 30 40 50 FEET BLOCKS OR PRECAST RISERS H-10 FYP.) 3' 4' SIDES 19.5' LOT SIZE >°O 'G°O°On 00o_o 00'. °o°o°000G 0°0°p0 'o°opo°o a o°G°��G„ o�;000:o� 16.63 , M�-O-LJIJ �a000aaaooa �aaa00000aa LEACHING CHAMBER BY ACME PRECAST OR EQUAL. (2) UNITS REQUIRED MIN. 10.6' BOTTOM TH-1 NO GROUNDWATER FOUND SUITABLE SOILS TO BE CONFIRMED BY INSTALLER PRIOR TO INSTALLATION OF ANY PORTION OF SEPTIC SYSTEM, AND PRIOR TO ANY EXCAVATION/CONSTRUCTION FOR DWELLING NOTES 1. DATUM IS APPROXIMATE NGVD 2. MUNICIPAL WATER IS AVAILABLE 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. I 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.). 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. orse O Pond d Rd � ck SSI°n B° a ndy a _D nd 0 �o 0 �o Gf� L u LOCUS MAP NOT TO SCALE ASSESSORS MAP 38 PARCEL 69 LOCUS IS WITHIN FEMA FLOOD ZONE "C" ZONING SUMMARY ZONING DISTRICT: R-25 DISTRICT MIN. LOT SIZE 25,000 S.F. MIN. LOT FRONTAGE 150' MIN. FRONT SETBACK 30' MIN. SIDE SETBACK 15' MIN. REAR SETBACK 20' BLDG COVERAGE 25% PROP COVERAGE 11.8% SITE IS NOT LOCATED WITHIN APD SYSTEM DESIGN: 'jr it %ur1vL LIiJ VJL f\ IS I�iIJ I' ALLOWED DESIGN FLOW: 3 BEDROOMS ® 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW EXISTING SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL: 471 S. F. 349 GPD USE (2) 500 GAL. H-10 LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 12 FEATHERBED LANE WEST YARMOUTH PREPARED FOR CHRIS CHAPIN , MA OF r ` NOVEMBER 11, 2013 .• .� REV. 1/6/14 (DWELLING & SEPTIC REVISIONS) '; IE- '4 REV. 7/28/14 (DWELL) .P < I •c r \ �� � �r i, ..1 a` �;!<<� REV. 7/30/14 (BOH COMMENTS) No. ` 1 4, off 508-362-4541 S TE x� ` fax 508-362-9880 -, g3�p,downcope.com "V ROW c4►pe ea4giaeering, iac. 1 civil engineers surveyors ors ,r y DANIEL A. OJALA, P.E., P.L.S. 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675