HomeMy WebLinkAboutEngineered Plan - Rev. 2014 (VOID)ACCESS COVERS TO WITHIN 6" OF FIN. GRADE SYSTEM. PROFILE (NOT TO SCALE) 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. - CONCRETE COVERS TO WITHIN 3" GRADE I, t 2% SLOPE', REQUIRED OVER SYSTEM 21 .7' J, J, xj, PRECAST H-10 RISERS (TYP.) yo 4'OSCH40 PVC MORTAF _ PIPES LEVEL 1ST 2' 4'S COMPO1 ENDj *20.0' 1500 GAL H-10 14" :. 10„ ➢ o�o,�.,� opo .. " . , , . TEE 0 0 0 0 ���® 0 �00 19.62' TEE SEPTIC TANK 19 37''00.0°° ° ° 0 0 0 0�0000�0000 70' °°°°°°°° °000000aoMoc� GAS BAFFLE:.; ° ° ° ° °o°000°o oOODOOoo�O�0 00 0 0 004' LIQ. LEVEL (ACME OR EQUAL)18.918.73 > °°o`oo°° oo°°o 0 0000 °0000000,°,0,°,0,°,0°,0°,0,°,0000000°,00,°,0,°,0°000°,0,°,00000° - E ' MIN. L H -10 500 G{ t 3/4" 1-1/2" DOUBLE WASHED STONE 4 ALL AROUND PRECAST STRUCTURES 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 25.0' X 12.83' N �- COMPACTION. (15.221 .[2]) WATER -TEST D'BOX FOR LEVELNESS C'. (2-% SLOPE) ( 1 +% SLOPE) (-!-% SLOPE) LEACHING FOUNDATION 19' SEPTIC TANK 40 D BOX 12 FACILITY J *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL I{ D ELEVATIONS UTILITIES AND ALL BUILDING SEWER OUTLETS AN PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEND- - 99- EXISTING CONTOUR X 99. EXIST. SPOT ELEV. 99 PROPOSED CONTOUR 99 PROPOSED SPOT EL. TH1 PERC. RATE _ Y TEST HOLE 2'/-- SLOPE OF GROUND CQ) UTILITY POLE LEACHING CHAMBER BY ACME PRECAST OR EQUAL. FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE WITNESS: AMY VON HONE, RS °o°o°o°o >o°o° DATE: 10/16 /13 >o�o�o0o� a�oaoaoM�o� PERC. RATE _ < 2 MIN/INCH o0000000 , °o°00000 16.63 SIDE SETBACK CLASS I SOILS REAR SETBACK LEACHING CHAMBER BY ACME PRECAST OR EQUAL. (2) UNITS REQUIRED ELEV. 25% 2 4 0» ' 21.6, 0„ A A LS LS 1OYR 4/2 1OYR 4/2 10" 11 " B B LS LS 25" 10YR 6/8 19 5, 26„ 10YR 6/8 PERC C I I C MS 1OYR 7/4 MS 1OYR 7/4 132 j 10.6' 120" NO GROUNDWATER ENCOUNTERED 3-258 X2.23 EXIST. HOUSE 00 / O � 2 EXISTING LEACHING FACILITIES, INCLUDING i STONE, TO BE PUMPED /x AND REMOVED IN ENTIRETY; REMOVE ALL C CONTAMINATED SOILS. Fq NOTE: GARAGE FOOTINGS TO BE PLACED ON NATURAL SOIL (NOT FILL) COORDINATE TIMING WITH / OWNERS x 21.75 / BLOCKS OR PRECAST RISERS H-10 YP.) 3 19.5' DISTRICT SIDES LOT SIZE °o°o°o°o >o°o° oaao _b .� as oaoaoaaao�o >o�o�o0o� a�oaoaoM�o� >0000000o aa��a000aoa o0000000 , °o°00000 16.63 SIDE SETBACK 15' MIN. REAR SETBACK LEACHING CHAMBER BY ACME PRECAST OR EQUAL. (2) UNITS REQUIRED COVERAGE 10.6' BOTTOM TH-1 NO GROUNDWATER FOUND �i J SUITABLE SOILS TO BE CONFIRMED BY INSTALLER otic PRIOR TO INSTALLATION OF ANY PORTION OF SEPTIC SYSTEM, AND PRIOR TO ANY 9-1.63 EXCAVATION/CONSTRUCTION FOR DWELLING \ 91.18 \ \ 7 \ 700g o f� ti a` NcF DECK x 21.57 / / PROP. { GAR. x .60 I (SLAB) TH 1 ,. / TH 2 PROP. 3 BR SHED / 1.58 DWELLING x 4.67 TOP FNDN. EL. 23.3' X z / h x x ELEV. HIGH PT. / X, / M xI' 21.6' x 21. x,1.19 � � / \ x 21.85 .61 x 21. ,��bl�- 6x 21.30 �Q• �. x ;21.22 / x 2 69 x 21.98 7S6 `97 �i 19.4' �NF / X1.69 x21.04 / -21.30 BENCHMARK: USE SURVEY SPIKE IN x 21-41. GROUND AT ELEV. 21.7' -- \ I, 11.6' Scale:1 "= 20' 0 10 20 30 40 50 FEET N x 20.83 x 20.97 IN NOTES 1. DATUM IS APPROXIMATE NGVD 2. MUNICIPAL WATER IS AVAILABLE 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 000' 1 .27 1 x 9.14 17.70 LOT 7 ' 16,683 SFS o� v x 9.53 X .10 0 oma. DATE .. •x�� � �eu;I�� Departa�e�at li GVEED ame Dzte orse O •Pond d Rd B0A o ndy a _D nd 0 co 0 �o L u c Q. LOCUS MAP NOT TO SCALE ASSESSORS MAP 38 PARCEL 69 LOCUS IS WITHIN FEMA FLOOD ZONE "C" .ZONING SUMMARY ZONING DISTRICT: R-25 DISTRICT MIN. LOT SIZE 25,000 S.F. MIN. LOT FRONTAGE 150' MIN. FRONT SETBACK 30' MIN. SIDE SETBACK 15' MIN. REAR SETBACK 20' BLDG COVERAGE 25% PROP COVERAGE 11.8% SITE IS NOT LOCATED WITHIN APD SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW EXISTING SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 2 (25 + 12.83) 2 (.74) = 112 GPD BOTTOM 25 x 12.83 (.74) = 237 GPD TOTAL: 471 S. F. 349 GPD USE (2) 500 GAL. H-10 LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE ALL AROUND MA APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF � DA 12 �EATHERBEDNE:, - WEST�YARMOUTH J N o l s�J 3: I PREP ED FO� CHRIS CHAPIN S g° i I NOVEMBER 11, 2013 REV 1/6/14 (DWELLING & SEPTIC REVISIONS) off 508-362-4541 fax 508-362-9880 I downcape.com down cafe eaineering, i7c. civil engineers land surveyors A • 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675