Loading...
HomeMy WebLinkAboutEngineered Plan - 2015SITE PLAN N SCALE:. 1 „ _ 20' B.M. = 100.00' ON TOP CORNER OF FRONT STOOP (ASSUMED) D OND iROA HORSE Pco 40 WIDE ------------ 0) -----------rn 97.39f ;•''... '. 47.23 97.98' ii0' P >: I� ••45':: I� 95.90, X 97. , w4�kwq 98.4 97.79 M �o 98.65' i e < i / 78.4 Z 97.56' it7 i C. c C� a (}� eek O...... 90 O .0 fr1 LOT 10 AREA 21,590± s ft. e e Of q• - 96.44,. 1 169.40' s .GENERAL N0TES � Lavender Rd. 1. ADDRESS: #4 HORSE POND ROAD, YARMOUTH n 2. ASSESSORS NUMBER: �.°iAP 46 PARCEL 59 - rn 3. DEVELOPER'S LOT: LOT #10 :33' ° Orchid Ln 4. TOPOGRAPHIC INFORMATION WAS COMPILED FROM AN ON THE vemen� 9'9 edge 09 of ►'�- DEPTH GROUND INSTRUMENT SURVEY. ELEV. _)3 Se Pond Rd. --�"- 99.2' 5. TOWN WATER IS PROVIDED TO THE SITE & SURROUNDING PROPERTIES. o 1OYR3/2 6. If, during installation the contractor encounters any 2.5Y6/1 ° SITE loamy sanj C.B. fnd _ 6. NO WETLANDS ARE LOCATED WITHIN 150 FEET OF THE PROPOSED SAS. oamy sand ! Cn 7. REFERENCE PLAN: LAND COURT PLAN 38064B 97.2' 32" m -c lsand "- Ji REFERENCE PLAN: "CERTIFIED PLOT PLAN", LOCATION: WEST YARMOUTH Glen E. Harrington, R.S. - guck Island Road lsand ° SCALE: 1 "=30', DATE: APRIL 26, 1977 BY JOSEPH W. MAHAR, JR. 89:2'- 50" 2.5Y7/4 7. 8. THE SITE IS LOCATED WITHIN A ZONE OF CONTRIBUTION (ZONE II). 1'20" 1 92' 9. THE UTILITIES WERE LOCATED BY DIGSAFE CONFIRMATION,, #20151607080. -% 8. Install Tuf-Tite gas baffles or equal on septic . tank outlet CD 9. 10. "W. YARMOUTH" X 99,31 wells are within proposed T 4- N 11. The existing leach pit shall be, pumped and backfilled. 0 8.58' n 0 _ � CROWELL ROAD #216. tAIGGINS 46-60 - WATER TOW N SOIL EVALUATION 8c PERK TEST Date of SOIL EVALUATION: April 23, 2015 Evaluation Performed By: Glen E. Harrington, R.S. Excavator: Mike Leary Percolation Rate: < 2 mpi, 24 gals applied during presoak Witness: Amy Von . Hone, R.S., BOH Agent ,1 Test Hole No.:1, _ DEPTH SOILS ELEV. 0 99.2' and local Board of Health Regulations. 0/A/E Tel: 774-238-1813 1 . 1OYR3/2 6. If, during installation the contractor encounters any 2.5Y6/1 6" loamy sanj 98.7' [m' � a1 f`r Bw oamy sand ! Cn 24" 10YR5/6 97.2' 32" m -c lsand "- Ji 2.5Y7/4 Glen E. Harrington, R.S. C lsand ° m -c 89:2'- 50" 2.5Y7/4 7. No vehicle or heavy machinery shall drive over the 1'20" 1 92' LOCOS 99.20' n 99 10 Design. Calculations NO SCALE Number of Bedrooms: 2 EXISTING (DEED RESTRICTION REQ'D) ss A D.P. Garbage Disposal: No 4 Icket fence 8.54 Leaching Capacity Required: 330 Gal./Day (MIN. PER TITLE V) Application Rate for <2 min. inch 0.74gal/sq. � PP = ft. / � � , Proposed Leaching Structure: 1-25 x13 x2 Leaching Trench o f Bottom Leaching Area Provided = 325 Sq. Ft. 98 0 Side Leaching Area Provided = 152 sq. ,f•c. :3 0) Total Leaching Area Provided = 477 sq. ft. Leaching Capacity Provided =477 sq. ft X 0.74 gal/sq.ft.=353 gpd. 0 01 / 00 97.69 0 o 97 CONSTRUCTION NOTES rn D O 1. Contractor is responsible for Digsafe notification ° and protection of all underground utilities and pipes. .96 2. The septic,�tank and distribution box shall be set level on 6 of 3/4"-11/2" stone. 95.95' 3. Backfill should be clean sand or gravel with no - '95 stones over 3" in size. 4. This system is subject to inspection during installation 94 to Glen .: E -.H ;-rinc; t .^ . R:c.` ,- 93 5. The contractor shall install this system. in accordance Test Hole No. 2 DEPTH SOILS ELEV. 0 99.2' and local Board of Health Regulations. 0/A/E Tel: 774-238-1813 1 . 1OYR3/2 6. If, during installation the contractor encounters any 2.5Y6/1 5" loamy sanc 98.78' [m' � a1 f`r Bw loamy sand ! Cn 22" 1OYR5/6 97.37' the installer shall halt installation and immediately notify m -c lsand "- Ji 2.5Y7/4 Glen E. Harrington, R.S. C _ 1'20" 89:2'- [•1f No Observed Ground Water No Observed Ground Water Existing Dwelling - First Floor=100.71' Existing Grade 98.5'± CELLARSeptic tank covers must be WALL '' within 6" of finished grade S = 0.02 ' ft S=0.01', 8' . EXISTING 1000 GAL 34' SEPTIC TANK Inv. elev.= 97.0'± H-10 E _ Install Gas Faffle Inv. elev.=96.76' or a uo 6" OF 3/4--11/2- STONE 3 HOLE H-20 DIST. BOX Finished grade over system=2% slope away WITHIN DE OF one chamber shall be provided with cover within 6" of grade Level for 2' S=0.01 ft/ft:::.:.:,,•::..:...::..:::.......... •::..... a `:asp s" L, . 4. SEC : J �" 'J CROSS gECTIO 3 HOLE H-20 DISTRIBUTION BOA PROPOSED SEPTIC SYSTEM REPAIR N01" TO SCABS PREPARED FOR LEGEND MIKE LEARY AT O EXISTING LEACH PIT 4 HORSE POND ROADYARMOUTH , M A � TO BE PUMPED AND FILLED EXISTING FO O H10 SEPTICOTANKAL Exis�Grade= 98'± DENOTES EXISTING OWNER: STEPHEN A. ANAGNOS Min. 2,x,o4.4s -1/8"-1/2" Double -Washed Stone SPOT GRADE or geo-textile filter cloth NOF 4 PREPARED BY: To of Peastone Elev.=96.4 , 95 EXISTING CONTOUR F,�' ., . ... ..... Q `tip Glen E. Harrington, R.S. Invert Elev.=95.91' DEEP TEST HOLE 0.1 np :......... . . .. ....... P=96.00' with Title V of the Massachusetts Environmental Code , Marstons Mills, MA 02648 Bottom of Leach Facility Elev.=93.91' and local Board of Health Regulations. in water I e Tel: 774-238-1813 1 . =96.17' 1 FACHING CHAMBERS 6. If, during installation the contractor encounters any Q Mai 1: gharr88@hotmail.com . OF STONE soil conditions or site conditions that are different [m' � a1 f`r W from those shown on the soil log or in this design ! Cn tc SYSTEM PROFILE D.P. I Bottom of Test 0 the installer shall halt installation and immediately notify Port "- Ji Glen E. Harrington, R.S. C _ 7. No vehicle or heavy machinery shall drive over the septic system unless noted as H-20 - septic components. -% 8. Install Tuf-Tite gas baffles or equal on septic . tank outlet tee. 9. 10. All piping shall be SCH 40 PVC. No located 150' of SAS. � wells are within proposed ALL OUTLET PEKES MOM THE `� 11. The existing leach pit shall be, pumped and backfilled. r:E.c,T < 1J";"•.ON BOX SHALL BE .�..T LE�Y:L F� A�- LEAST 2 �. S LEVEL T COVER � •::•s- 12 Install a 4 dia. SCH 40 PVC observation port, a s shown. iceac •`R"""'�' :•9 "a '''. •`•r'=k*' 2 - .�. 3.5, OU',1ET , -13. �.. The Contractor shall notify the. Board- of Health and the y DesignerKNOCKOUTMS - 40 f ti ,,,,,,,,,,,, at least 24 hours in advance to inspect and certify the system. °:2" INLET a `:asp s" L, . 4. SEC : J �" 'J CROSS gECTIO 3 HOLE H-20 DISTRIBUTION BOA PROPOSED SEPTIC SYSTEM REPAIR N01" TO SCABS PREPARED FOR LEGEND MIKE LEARY AT O EXISTING LEACH PIT 4 HORSE POND ROADYARMOUTH , M A � TO BE PUMPED AND FILLED EXISTING FO O H10 SEPTICOTANKAL Exis�Grade= 98'± DENOTES EXISTING OWNER: STEPHEN A. ANAGNOS Min. 2,x,o4.4s -1/8"-1/2" Double -Washed Stone SPOT GRADE or geo-textile filter cloth NOF 4 PREPARED BY: To of Peastone Elev.=96.4 , 95 EXISTING CONTOUR F,�' ., . ... ..... Q `tip Glen E. Harrington, R.S. Invert Elev.=95.91' DEEP TEST HOLE 0.1 np :......... . . .. ....... P=96.00' � t , Marstons Mills, MA 02648 Bottom of Leach Facility Elev.=93.91' existing in water I e Tel: 774-238-1813 1 . =96.17' 1 FACHING CHAMBERS Approx. location Mai 1: gharr88@hotmail.com . OF STONE DRAWN BY: GEH DATE: APRIL 28, 2015 SYSTEM PROFILE D.P. I Bottom of Test 0 Observation Port � t