Loading...
HomeMy WebLinkAboutEngineered Plan - 2015SYSTEM PROFILE (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2" PEASTONE OR GEOTEXTILE 25.5' FILTER FABRIC OVER STONE 24.5 MINIMUM .75' OF COVER OVER PRECAST PRECAST H-10 NOTE: MIN. WALL THICKNESS 2" RISERS (fYP.) 4"0SCH40 PVC 2'a 23.75' PIPES LEVEL 1ST 2' n ENDS ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. I CONCRETE COVERS TO WITHIN 3" GRADE 2% SLOPE REQUIRED OVER SYSTEM 24.5• BLOCKS OR PRECAST RISERS MORTAR ALL INVERT IN 20.67' COMPONENTS (TYP.) ;oo�oe� ,°°°°°°°° 10" EXISTING 14" E a ° < . ° ° ° °. �ElM '®DDD®®® ;o°o°o°o° TEE SEPTIC TANK TEE f*22.3' °og00000 ®®��0� ®®®C�®��®��(]000000000000 6" MIN. SUMP p >°° ° °°° 000°°000°°000000, o°o°o° ° ®®®DDD DD® ®������ ;oo°000°oGAS BAFFLE ::: , o 0 0^0 0_ 12" MIN. INT. DIM. �i °°°000 0®��®0®�O ��®®����(]® °o°o°o°20.8' ° °o° °o°o°000 JE 20.97' °o°°°o°o :..:. : .• r•` WATERTEST D'BOX ''t '• ."0000000°0°0°00000000000000000°o00000000°0°0` FOR LEVELNESS `H-10 500 GAL. LEACHING 'CHAMBERS BY ACME PRECAST OR EQL 0000Oo�O�n�/�f�n�°l�'°1�0�OO�G0U�n�(�`�n�n�n�n07�GOD0. 3/4"-1-1/2" DOUBLE WASHED STONE 4' MIN. (4) :UNITS REQUIRED ALL AROUND PRECAST STRUCTURES 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 42.0' X 10.83' COMPACTION. (15.221 [21) (-2-.-5-% SLOPE) (--!-% SLOPE) 1 LEACHING 1 13.5' BOTTOM TH-1 FOUNDATION- EXIST. SEPTIC TANK 14' D' BOX 15' FACILITY NO GROUNDWATER FOUND *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS 1000 GALLONS AND ITS SUITABILITY FOR RE -USE. REPLACE PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM WITH 1500 GALLON SEPTIC TANK APPROPRIATE TO SITE CONDITIONS IF NOT SUITABLE SIDES 121.5' 99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. -[991- PROPOSED CONTOUR C98.41 PROPOSED SPOT EL. TH1 Y TEST HOLE 2% SLOPE OF GROUND UTILITY POLE C � FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 : AMY VON HONE, RS WITNESS DATE: 4/30/1,4 r �, PERC. RATE _ < 7 MIN/INCH CLASS I SOILS 0" 8" 2011 PERC 72" 4 A LS 1OYR 3/2 B LS 1OYR 4/6 C1. LFS 1OYR 6/4 C2 MS 2.5Y 7/4 132" 13.5' NO GROUNDWATER ENCOUNTERED ELEV. 24.5' 22.8' 18.5' DICE #15-081 0E WO O L�� IC_40, WID ) (PUgo,AD MAP 60 j PARCEL 60 � 186 NOTES 1. DATUM IS ASSUMED 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 24.10 X 0 GPD (2) = 880 24.01 23.70 i4 I 1000 GAL. SEPTIC TANK a m 18 3.10 C � W o 24.41 3.52 23.28 Cn 23.37 EXISTINp 2�{. 2d;2 SIDES: 2 (42.0 + 3.01 PP�vE Or\ I m 7 X 23 < z sz tik 665 S.F. o x2.88 5 .94 2 3 G - Cn -,13 . 23. 5 / G 4.9\N 4. V'N �- �Z L 5.4 75 4.74 G AT SIDES c� 14.43 t '.58 o o X24.59. _ �I w X. 04.� W 3.71 3.91 / x .84 X2 i X 24.34 m0 `-' i i Scale:1 "= 20' 0 10 20 30 40 50 FEET 0 X 24.39 n AP 60 PARCEL 67 0.22 A C. 7X 25.03 F BENCHMARK �,89 TOP OF STEP EL. = 25.4' zj \q r X 24.59 LOCUS MAP NOT TO SCALE ASSESSORS MAP 60 PARCEL 61 SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED EXISTING 4 BEDROOM DWELLING DESIGN FLOW: 4 BEDROOMS @ 110 GPD = 440 GPD USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2) = 880 **RE -USE EXISTING 1000 GAL. SEPTIC TANK a 9 C � W o LEACHING: SIDES: 2 (42.0 + 10.83) 2 (.68) = 144 GPD BOTTOM 42.0 x 10.83 (.68) = 309 GPD TOTAL: 665 S.F. 453 GPD USE (4) H-10 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 4' STONE AT ENDS AND 3' STONE AT SIDES APPROVED DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF , MA 10 INDIAN MEMORIAL DRIVE Jair _.e ;SOUTH YARMOUTH, MA EieMAP 60 > PARCEL 62 1-t, I PREPARED FOR Date CARLA CHAPASKO DATE: MAY 4, 2015 off 508-362-4541 fax 508-362-9880 I downcope.com d0 W11 c41,0e eJ7 14eerin,g, Inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 15-081 CHAPASKO.DWG DATE UANILL A. UJALA, r.L., r.L.�.