Loading...
Decision 3611 Site Plan of Landl L LEWI I LOCUS MAP ASSESSOR'S MAP 21. PARCELS 3I. 33 AND 45 OWNER OF RECORD: OCEAN RESORTS MARKETING. INC. 11846 ISLAND LAKES LANE BOCA RATON FL 33498 ASSESSOR'S MAP 21, PARCEL 46 OWNER OF RECORD: JOSEPH JACOBSON P.O.BOX 271 MIDDLEBORO, MA 02346 ZONING DISTRICTS, R-25. MIN FRONTAGE - 150' SETBACKS: FRONT - 30'. SIDE - 15'. REAR - 20' MAXIMUM BUILDING COVERAGE - 25% FLOOD ZONE B. Al2 (EL 12). Al2 (EL 10) AND V15 (£L 13). MAP 250015 0005 D. DATED 7/2/92 GENERAL NOTES: 1. PROPERTY LINE INFORMATION WAS COMPILED FROM AVAILABLE PLANS AND DEEDS OF RECORD AND DOES NOT REPRESENT AN ACTUAL ON THE GROUND SURVEY. 2. TOPOGRAPHIC INFORMATION WAS OBTAINED BY ELECTRONIC SURVEY METHODS. 3. ELEVATIONS SHOWN REFER TO NATIONAL GEODETIC VERTICAL DATUM (N.G.V.D.). FOR BENCH MARKS SET SEE SITE PLAN. 4. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEED RESTRICTIONS OR ZONING REGULATIONS. IT SHALL REMAIN THE CLIENTS RESPONSIBILITY TO OBTAIN ALL PERMITS. SPECIAL PERMITS. VARIANCES ETC. FOR THIS PROJECT. 5. IT SHALL REMAIN THE CLIENT'S RESPONSIBILITY TO HAVE THE PROPOSED BUILDING FOUNDATIONS DESIGNED TO ACCOUNT FOR THE EXISTING GRADE AND SOIL CONDITIONS AT THE LOCATION OF THE PROPOSED BUILDING. 6. ANY RETAINING WALL SHOWN ON THIS PLAN IS FOR LOCATION ONLY AND SHALL BE DESIGNED IN ACCORDANCE WITH STANDARD PRACTICE. 7. THIS PROJECT SHALL MEET ALL PROVISIONS OF THE TOWN OF YARMOUTH SIGN CODE. 8. BEFORE CONSTRUCTION CALL -DIG -SAFE'. 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UTILITIES. 9. ALL CONSTRUCTION METHODS AND MATERIALS AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. IO.ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 2' IN DEPTH SHALL BE CAPABLE OF WITHSTANDING H-20 WHEEL LOADS. II.SEPTIC TANK AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE AND WATERTIGHT. I2.ALL SEWER PIPE SHALL BE SCHEDULE 40 OR APPROVED EOUAL. 13.ALL EXISTING CESSPOOLS TO BE PUMPED DRY. REMOVED BACKFILLED WITH CLEAN SAND AND COMPACTED. 14.ALL UNSUITABLE MATERIAL IA 6 8 HORIZONS) ENCOUNTERED BELOW THE INVERT OF THE LEACHING FACILITY TO BE REMOVED FOR A DISTANCE OF 5' AROUND AND REPLACED WITH SAND IN ACCORDANCE WITH TITLE 5. 15.D -BOX TO BE WATER TESTED TO CHECK FOR LEVEL. 16.EX1STING INVERT AT SYSTEM fl TO BE RAISED 1.64' 17. YARMOUTH HEALTH DEPT TO INSPECT REMOVAL OF EXISTING SYSTEM AND SOIL REMOVAL AS REOUIRED BEFORE PLACEMENT OF FILL. 18.DEEP TEST HOLES AND PERCOLATION TEST TO BE DONE PRIOR TO ISSUANCE OF A PERMIT FOR CONSTRUCTION OF THE SEPTIC SYSTEMS. 19. THE BUILDINGS WITHIN THE VELOCITY ZONE SHALL HAVE THE FOUNDATIONS DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH FLOOD ZONE REGULATIONS. AREA CALCULATIONS: TOTAL LOT AREAS (31 6 33)- 18.687t S.F. TOTAL BUILDING AREA - 3,0151 S.F. - 16x OF SITE TOTAL LOT AREAS (45 6 46)- 2/.400t S.F. TOTAL BUILDING AREA 3.7851 S.F. - 18x OF SITE PARKING CALCULATIONS: RESIDENTIAL. HOTEL/MOTEL -.1.1 SPACE / UNIT 9 TOTAL UNITS x 1.1 - 9.9 SPACES REQUIRED PARKING PROVIDED - IB SPACES 10' WIDE HARDENED \ SURFACE FREE OF FENCES. PL ANTI NGS AND BUILDINGS FOR \ EMERGENCY ACCESS F� BO0 0 PROPOSED 4' WIDE PLANTING STRIP OF A 5' HIGH DENSE PLANTED EVERGREEN SHRUB EXISTING CONDITIONS 16 UNIT. 16 KITCHEN. 19 BEDROOM COTTAGE COLONY PROPOSED PLAN 9 UNIT. 9 KITCHEN. 16 BEDROOM SEASONAL TIME SHARE CONDOMINIUM VIDE PLANTING HIGH DENSE iREEN SHRUB LL � PARCEL 31� r 65841 S.F. R' 1?O. a l n, / 1l �1 2cp M CB/DB.EIPD MIN 2. OF PEASTONE "A . J , b Lf - °6' 'a a•`L 9.05 8.5 A 7.5 VAPOR BARRIER REVISED: 3 OUTLET 7 FLOWDIFFUSOR CHAMBERS EL 6.5 MAX MARCH J. 2000 D -BOX W/4' STONE AROUND. 12 'x 64'x 1 3/4' - 11/2' DIA. 2500 GAL WASHED STONE SEPTIC TANK 6' CRUSHED STONE BASE Yarmouthport, f rl" 2I J , a, INVERT ELEVATIONS: DESIGN CRI TER IA: t INVERT AT BUILDING: i DESIGN FLOW: %• 1 9.5 6 BEDROOMS AT 110 G.P.D. PER F1ELD:CFW/EEK 9� ?o i • \\\° 9 N o, INVERT IN DIST. BOX: 9.05 INVERT OUT DIST. BOX: 2 NO GARBAGE GRINDERS a, f 5 COQ' ry 6.5 BOTTOM OF LEACH CHAMBER: \F o JI LL � PARCEL 31� r 65841 S.F. R' 1?O. a l n, / 1l �1 2cp O CEA N V/ E -W VILLAS MIN 2. OF PEASTONE "A . 51 EL D.O .MIN S , �' 4o Mlc POLY I - °6' 'a a•`L 9.05 8.5 REVISED: 7.5 VAPOR BARRIER REVISED: 3 OUTLET 7 FLOWDIFFUSOR CHAMBERS EL 6.5 MAX MARCH J. 2000 D -BOX W/4' STONE AROUND. 12 'x 64'x 1 3/4' - 11/2' DIA. 2500 GAL WASHED STONE SEPTIC TANK 6' CRUSHED STONE BASE Yarmouthport, f PROF I L E: NOT TO SCALE a, INVERT ELEVATIONS: DESIGN CRI TER IA: t INVERT AT BUILDING: 10.0 DESIGN FLOW: I � \ \ \ 9.5 6 BEDROOMS AT 110 G.P.D. PER F1ELD:CFW/EEK INVERT OUT SEPTIC TANK: 9.25 BEDROOM EQUALS 660 G.P.D. o, INVERT IN DIST. BOX: 9.05 INVERT OUT DIST. BOX: 8.88 NO GARBAGE GRINDERS INVERT IN LEACH CHAMBER: 6.5 BOTTOM OF LEACH CHAMBER: 7.5 SEPTIC TANK REOUIRED:660 G.P.D. X 2002 - 1320 GAL. AREA HIGH GROUND WATER: 2.5 SEPTIC TAN r NEW $AS yF��F`pP SYSTEM •I F s, R MOVE STING 0P000, PARCEL 33 \ SEPTI( SYSTEM.? `oREMOV£ \`lJ /y' oy Gyi 121031 S.F. `\ TANK ��t Gy�j, f`P� %v GkAiS rye Ls I\ � J % O '11. �* Bim+ -l.'•. / � 1 • ,/ / h anti ��, � 02 o, .° SEP' ? TAM / g1 \ it 4 F CSA r - 'A \ � n z J• 41 0 SyoPyR��O 5 LEGEND ■ CONCRETE BOUND FOUND ® WATER GATE -W- WATER L I NE O HYDRANT .. ® GAS GATE -G- GAS LIKE' 0 CATCH BASIN -0 UTILITY POLE W/ GUY WIRE - OHW - OVER HEAD WIRES. -T- UNDERGROUND TELEPHONE LINE EXISTING SPOT ELEVATION EXISTING CONTOUR 0 4 PROPOSED SPOT ELEVATION 3 SYSTEM #/ ACCESS COVERS MUST BE WITHIN 9- MINIMUM. 6' OF FINISH GRADE 3' MAXIMUM COVER FIRST TO / BE LEVEL K PROVIDED• 2500 GAL 2 COMPART- MENT TANK (SECT 15.223(1)(6) 6 15.224) SOIL ABSORPTION SYSTEM REOUIRED: DESIGN PERC RATE < 5 MIN/INCH SOIL TEXTURAL CLASS - I EFFLUENT LOADING RATE - 0.74 GPD/SF 660 ORD / 0.74 GPD/SF - 892 S.F. REOUIRED PROVIDED: 7 FLOWDIFFUSOR CHAMBERS W/4' STONE AROUND. A-920 S.F. 920 S.F. / 0.74 - 680 G.P.D. S YS TEM #2 ACCESS COVERS MUST BE WITHIN 9- MINIMUM. 6' OF FINISH GRADE 3' MAXIMUM COVER 16.0 FIRST 2' TO BE LEVEL MIN 2' OF PEASTONE 4• DIAM PIP 3/4' - 1 I/2' DIA. o Lf� o II 5 II.IB 2• H-20 �- WASHED STONE I 1 . '� 11F" " 11.35 1 10.5 8. 5 9 OUTLET 14-500 GAL LEACHING CHAMBERS O -BOX W/4' STONE SIDES. I' ENDS, 16.5'x 70'x 2' ScPTi PTI ' CAL T/, NK H-20 14-20 6' CRUSHED STONE BASE PROF I L E: NOT TO SCALE INVERT ELEVATIONS: DESIGN CRITERIA: INVERT AT BUILDING: 12.3 DESIGN FLOW: INVERT IN SEPTIC TANK: 11.75 /0 BEDROOMS AT 110 G.P.D. PER INVERT OUT SEPTIC TANK: 11.5 BEDROOM EOUALS 1100 G.P.D. INVERT IN DIST. BOX: 11.35 INVERT OUT DIST. BOX: Il.18 NO GARBAGE GRINDERS INVERT IN LEACH CHAMBER: 10.5 BOTTOM OF LEACH CHAMBER: 8.5 SEPTIC TANK REOUIRED: 1100 G.P.D. X 200% - 2200 GAL. AREA HIGH GROUND WATER: 2.5 SEPTIC TANK PR VAR I ANCES REQUIRED TOWV OF YARMOUTH HEALTH REGULATIONS: SECTION 3.7: LOCATION 100 IS REOUIP£D BETWEEN THE SAS AND A WETLAND RESOURCE AREA. THE SAS IS PROPOSED TO BE 72' TO THE TOP OF BANK AND 106' TO MHW. THE RESERVE IS PROPOSED TO BE 50' TO THE TOP OF BANK AND 92' TO MHW. TITLE 5. SECTION 15.211:(/) MINIMUM SETBACK DISTANCES 10' 1S REOUIRED BETWEEN THE SEPTIC TANK AND THE PROPERTY LINE. THE SEPTIC TANK IS PROPOSED TO BE 6' FROM THE STREET LINE. 10' IS REOUIRED BETWEEN THE RESERVE AREA AND THE PROPERTY LINE. THE RESERVE AREA IS PROPOSED TO BE 5' FROM THE PROPERTY LINE. 0 10 20 OVID£D• 4000 GAL 2 COMPART- MENT TANK (SECT 15.223(I)(b) 6 15.224) SOIL ABSORPTION SYSTEM REQUIRED: DESIGN PERC RATE < 5 MIN/INCH SOIL TEXTURAL CLASS - I EFFLUENT LOADING RATE - 0.74 GPD/SF 1/00 GPD / 0.74 GPD/SF - 1486 S.F. REOUIRED PROVIDED: /4-500 GAL LEACHING CHAMBERS W/4' STONE AROUND. A-1501.4 S.F. 1501 S.F. x 0.74 - 1111 G.P.D. RESERVE AREA 16.5'W x 70'1 x 2'd - 1501 S.F S / TE PLAN OF LAIVO O CEA N V/ E -W VILLAS MIN 2. OF PEASTONE "A . 51 EL D.O .MIN S 2 9.25 8.88 4R / �' 4o Mlc POLY I - °6' 'a a•`L 9.05 8.5 REVISED: 7.5 VAPOR BARRIER REVISED: 3 OUTLET 7 FLOWDIFFUSOR CHAMBERS EL 6.5 MAX MARCH J. 2000 D -BOX W/4' STONE AROUND. 12 'x 64'x 1 3/4' - 11/2' DIA. 2500 GAL WASHED STONE SEPTIC TANK 6' CRUSHED STONE BASE Yarmouthport, MA. 02675 PROF I L E: NOT TO SCALE INVERT ELEVATIONS: DESIGN CRI TER IA: INVERT AT BUILDING: 10.0 DESIGN FLOW: INVERT 1N SEPTIC TANK: 9.5 6 BEDROOMS AT 110 G.P.D. PER F1ELD:CFW/EEK INVERT OUT SEPTIC TANK: 9.25 BEDROOM EQUALS 660 G.P.D. DRN: SAH INVERT IN DIST. BOX: 9.05 INVERT OUT DIST. BOX: 8.88 NO GARBAGE GRINDERS INVERT IN LEACH CHAMBER: 6.5 BOTTOM OF LEACH CHAMBER: 7.5 SEPTIC TANK REOUIRED:660 G.P.D. X 2002 - 1320 GAL. AREA HIGH GROUND WATER: 2.5 SEPTIC TAN K PROVIDED• 2500 GAL 2 COMPART- MENT TANK (SECT 15.223(1)(6) 6 15.224) SOIL ABSORPTION SYSTEM REOUIRED: DESIGN PERC RATE < 5 MIN/INCH SOIL TEXTURAL CLASS - I EFFLUENT LOADING RATE - 0.74 GPD/SF 660 ORD / 0.74 GPD/SF - 892 S.F. REOUIRED PROVIDED: 7 FLOWDIFFUSOR CHAMBERS W/4' STONE AROUND. A-920 S.F. 920 S.F. / 0.74 - 680 G.P.D. S YS TEM #2 ACCESS COVERS MUST BE WITHIN 9- MINIMUM. 6' OF FINISH GRADE 3' MAXIMUM COVER 16.0 FIRST 2' TO BE LEVEL MIN 2' OF PEASTONE 4• DIAM PIP 3/4' - 1 I/2' DIA. o Lf� o II 5 II.IB 2• H-20 �- WASHED STONE I 1 . '� 11F" " 11.35 1 10.5 8. 5 9 OUTLET 14-500 GAL LEACHING CHAMBERS O -BOX W/4' STONE SIDES. I' ENDS, 16.5'x 70'x 2' ScPTi PTI ' CAL T/, NK H-20 14-20 6' CRUSHED STONE BASE PROF I L E: NOT TO SCALE INVERT ELEVATIONS: DESIGN CRITERIA: INVERT AT BUILDING: 12.3 DESIGN FLOW: INVERT IN SEPTIC TANK: 11.75 /0 BEDROOMS AT 110 G.P.D. PER INVERT OUT SEPTIC TANK: 11.5 BEDROOM EOUALS 1100 G.P.D. INVERT IN DIST. BOX: 11.35 INVERT OUT DIST. BOX: Il.18 NO GARBAGE GRINDERS INVERT IN LEACH CHAMBER: 10.5 BOTTOM OF LEACH CHAMBER: 8.5 SEPTIC TANK REOUIRED: 1100 G.P.D. X 200% - 2200 GAL. AREA HIGH GROUND WATER: 2.5 SEPTIC TANK PR VAR I ANCES REQUIRED TOWV OF YARMOUTH HEALTH REGULATIONS: SECTION 3.7: LOCATION 100 IS REOUIP£D BETWEEN THE SAS AND A WETLAND RESOURCE AREA. THE SAS IS PROPOSED TO BE 72' TO THE TOP OF BANK AND 106' TO MHW. THE RESERVE IS PROPOSED TO BE 50' TO THE TOP OF BANK AND 92' TO MHW. TITLE 5. SECTION 15.211:(/) MINIMUM SETBACK DISTANCES 10' 1S REOUIRED BETWEEN THE SEPTIC TANK AND THE PROPERTY LINE. THE SEPTIC TANK IS PROPOSED TO BE 6' FROM THE STREET LINE. 10' IS REOUIRED BETWEEN THE RESERVE AREA AND THE PROPERTY LINE. THE RESERVE AREA IS PROPOSED TO BE 5' FROM THE PROPERTY LINE. 0 10 20 OVID£D• 4000 GAL 2 COMPART- MENT TANK (SECT 15.223(I)(b) 6 15.224) SOIL ABSORPTION SYSTEM REQUIRED: DESIGN PERC RATE < 5 MIN/INCH SOIL TEXTURAL CLASS - I EFFLUENT LOADING RATE - 0.74 GPD/SF 1/00 GPD / 0.74 GPD/SF - 1486 S.F. REOUIRED PROVIDED: /4-500 GAL LEACHING CHAMBERS W/4' STONE AROUND. A-1501.4 S.F. 1501 S.F. x 0.74 - 1111 G.P.D. RESERVE AREA 16.5'W x 70'1 x 2'd - 1501 S.F S / TE PLAN OF LAIVO O CEA N V/ E -W VILLAS WES T YARMOUTH. "A . P R EP A REO F O R: ROBERT OS TELL //VO SCAL E : / " - 20 • SEP TE -MBE -I? 0. / 999 REVISED: OCTOBER 4, 1999 REVISED: NOVEMBER 24, 1999 REVISED: MARCH J. 2000 REVISED: APRIL 12. 2000 EAGLE SURVEYING, INC 923 Route 6A Yarmouthport, MA. 02675 ( 508 ) ( 508 ) 362-8132 432-5333 40 JOB NO: 99-026 F1ELD:CFW/EEK I CALC: SAH CHECK: CFW DRN: SAH